background image

9

#33003

Subject to error and alteration

4. USB Isolator 2 kV HS, #33003

Function

The USB-Isolator 2 kV HS #33003 provides galvanic isolation for 
USB connections. The isolator is simply inserted into the existing 
USB connection and powered by an external power supply.

The isolator of type #33003 isolates Low-, Full- and HighSpeed USB 
connection galvanically with an isolation voltage of at least 2,000 V 
DC.

The bus speed is detected fully automatically.

Supply voltage

The USB-isolator requires an external power supply for powering 
the galvanically isolated circuitry of the isolator in addition to the 
bus-powered USB device.

A suitable wall mount adapter is included with the isolator, though 
any 5 V DC power supply with a USB output can be used as long 

as  it  provides  an  output  current  of  at  least  1  A  and  fulfills  the 

requirements as outlined in the safety instructions.

The supply voltage is supplied to the isolatod side via a USB type-C 
socket. An appropriate adapter cable for connecting the power 
supply is also included with the Isolator.

 

1

NOTE

The USB A plug on the power cable must not be connected to a 
second USB port on the USB host or hub which is connected to the 
upstream port of the isolator. Such a connection would short-circuit 
the galvanic isolation and render it useless. A galvanically isolated 
voltage source is therefore mandatory.

Summary of Contents for 33003

Page 1: ...USB Isolator valid for 33003 USB Isolator 2kV HS Release 07 2023 Manual Startup and Application...

Page 2: ...any mistakes or misunderstandings you are aware of so that we can recognize and eliminate them quickly Perform work on and with W T products only as described here and only if you have read and under...

Page 3: ...Warning notice system 4 Qualified personnel 5 Disposal 5 Symbols on the product 5 2 Safety Instructions 6 Intended Use 6 Electrical safety 6 EMC 7 3 Introduction 8 4 USB Isolator 2kV HS 33003 9 Functi...

Page 4: ...ventive actions are taken 1 1WARNING Indicates a hazard which can result in death or severe injury if no appropriate preventive actions are taken 1 1CAUTION Indicates a hazard that can result in sligh...

Page 5: ...l are defined as those who are qualified by their training and experience to recognize risks when handling the described products and to avoid possible hazards Disposal Electronic equipment may not be...

Page 6: ...faces It is not permitted to use the isolator to protect personnel against contact with dangerous voltages If a safety critical electrical isolation is required please contact us Any other use or modi...

Page 7: ...plications and the stricter emissions limits for households and small businesses Therefore there are no EMC related limitations with respect to the usability of the devices in such environments Declar...

Page 8: ...s and do not have any reference to a second ground or to the earth conductor In other areas such as measurement equipment process control or medical technology galvanic isolation of the connected devi...

Page 9: ...or in addition to the bus powered USB device A suitable wall mount adapter is included with the isolator though any 5 V DC power supply with a USB output can be used as long as it provides an output c...

Page 10: ...cates correct power for the upstream side from the USB host or hub whereas the Power OUT LED indicates the correct power supply of the downstream side USB Isolator 2kV 33003 Power IN Power OUT USB A S...

Page 11: ...100 mA Downstream Port max 120 mA plus current draw of the USB device USB connections Upstream Port USB A plug with 20 cm cable Downstream Port USB A socket integrated in housing Ambient temperature...

Page 12: ...Wiesemann Theis GmbH Porschestra e 12 D 42279 Wuppertal Mail info wut de Web www wut de Tel 49 0 202 2680 110 Fax 49 0 202 2680 265...

Reviews: