27
W&T
Start-up
Subject to error and alteration
3�4 Initial web page
After the IP assignment, only the initial web page is availa-
ble during the initial commissioning. Here, the password of
the Microwall required for all further configuration accesses
must be assigned. At the same time, the IP basic parameters
of both network interfaces and the operating mode can be
determined.
Saving the initial web page does not involve any communica-
tion permissions. These must then be formulated in the form
of explicit whitelist rules.
i
When the interface
Network 1
is connected to the network,
the initial web page for assigning the system password
can be reached via the default IP or the IP address assigned
by WuTility. Make sure that no unauthorized access to the
Microwall occurs until the password is assigned on the initial
web page (e.g. by commissioning with a direct connection to
the respective PC).
If the IP address was assigned using the
WuTility
tool, select
the desired Microwall and click on the Browser button:
If access is to take place via the default IP address of the
Microwall, start a browser on the PC prepared from an
IP viewpoint. Enter the following URL in the address line:
https://190.107.233.110
The Microwall is equipped ex works with a self-signed certifi-
cate. Corresponding warnings of the browser must be ignored
and/or acknowledged when the initial web page is called. Af-
ter commissioning, the default certificate can be replaced by
an individual certificate.
All settings of the initial web page can be changed later via
the standard web-based management.
Summary of Contents for 55211
Page 6: ...W T ...
Page 7: ...7 W T Subject to error and alteration 1 Legal information and safety ...
Page 12: ...12 W T ...
Page 56: ...56 W T Operation modes and rule configuration ...
Page 80: ...80 W T WireGuard VPN client ...
Page 84: ...84 W T WireGuard VPN Box to Box ...
Page 111: ...111 W T Subject to error and alteration Appendix Technical data and form factor ...