background image

17

  

Initial start-up

6. Initial start-up 

After the SIP Ring Switch has been properly installed and wired, the power supply 

can  be  switched  on.  All  three  status  LEDs  should  light  up  briefly.  After  approx.  5 
seconds only the Power LED should remain on. The Status LED may flash. 

If the network connection is working, the green LED in the network socket signals an 
active link. The orange LED indicates the network speed:

On = 100MBit/s
Off = 10MBit/s 

Assigning the IP address

At delivery, the SIP Ring Switch is set to IP address 0.0.0.0.0 and DHCP is activated. 

Networks with DHCP

If a DHCP server is active in the network to which the SIP Ring Switch is connected, 
an IP address should be automatically assigned to the SIP Ring Switch. To be able 

to  specifically  access  the  SIP  Ring  Switch,  you  should  configure  a  reservation  in 

the DHCP server so that the SIP Ring Switch is always accessible under the same 
address. The required Ethernet address can be found on the white sticker on the 
device.

xxx

(If in doubt ask your network administrator)

Networks without DHCP

Install the WuTility program on a Windows PC (download from 

http://www.WuT.de

). 

If you do not have a Windows PC, read the subchapter 

Alternatives for IP address 

assignment

 in the appendix.

When WuTility is started, the local subnet is scanned and all detected W&T network 
components are listed. Select your SIP Ring Switch and click the 

IP address

 icon. 

Summary of Contents for 57753

Page 1: ...SIP Ring Switch valid for 57753 SIP Ring Switch 4xOut Release 1 68 September 2023 Manual Installation Startup and Application...

Page 2: ...ny of our statements without verification Please inform us of any error or misunderstanding you come about so we can identify and eliminate it as soon as possible Carry out your work on or with W T pr...

Page 3: ...roduct 6 2 Safety notices 7 General notices 7 Intended use 7 Electrical safety 7 EMC 8 Batteries 8 3 Quick Startup 10 Network connection 10 Supply voltage 10 IP address assignment 10 Function test 10...

Page 4: ...ettings 19 Configuring the Outputs 19 Date Time 19 Language Info 20 Password 20 Certificates 21 8 Basic applications 22 SIP Dialing via IP telephony 22 Browser access 24 Sending email 26 9 Actions 28...

Page 5: ...ventive actions are taken 1CAUTION Indicates a hazard that can result in slight injury if no appropriate preventive actions are taken 1NOTE Indicates a hazard which can result in equipment damage if n...

Page 6: ...uipment may not be disposed of with normal waste but rather must be brought to a proper electrical scrap processing facility Symbols on the product Symbol Explanation CE Mark The product conforms to t...

Page 7: ...esent manual Non intended use is any other use or any modification to the described devices Electrical safety 1WARNING Before beginning any kind of work on the SIP Ring Switch you must completely dis...

Page 8: ...ns and the stricter emissions limits for households and small businesses Therefore there are no EMC related limitations with respect to the usability of the devices in such environments The complete D...

Page 9: ...e clock module is located in a holder on the upper PCB After removing replacing the battery reassemble in reverse order Batteries and rechargeables must not be disposed of with normal waste recycling...

Page 10: ...tility After starting Wutility your SIP Ring Switch appears in the device list If multiple devices are shown please identify your device by the Mac address that is printed on a white sticker at the de...

Page 11: ...e port for initializing firmware updates are enabled DHCP is also enabled You can explicitly specify for all communication paths whether the outputs may be accessible A list of the currently open TCP...

Page 12: ...tion access with administrator login is required Application and access possibilities SIP The core function of the SIP ring switch is to switch outputs by dialing extension numbers in an IP PBX The co...

Page 13: ...an also access the SIP Ring Switch Actions Which output is to be switched to which state when a certain extension is called is determined by creating corresponding actions In addition actions can be c...

Page 14: ...ion in the control cabinet or sub distribution For mechanical fixation the SIP Ring Switch should be snapped onto a 35mm top hat rail according to DIN EN 50022 In doing so the Web IO takes up 45mm in...

Page 15: ...Reset Outputs max 4x500mA Vcc 0 1 2 3 12 24V DC 150mA Output Load Input Output Mode Check and LED Test shown on Reset Outp ON Inp ON URL ______________ 12 24V GND With a typical industrial power supp...

Page 16: ...used as re ference ground Here is an example of the wiring of output 1 12 24V GND Last Load SIP Ring Switch 57753 Digital 4xOut Power Status Error Reset Outputs max 4x500mA VCC 0 1 2 3 12 24V DC 150m...

Page 17: ...he network to which the SIP Ring Switch is connected an IP address should be automatically assigned to the SIP Ring Switch To be able to specifically access the SIP Ring Switch you should configure a...

Page 18: ...ust the IP address If you select Address range any network you can also enter parameters which are different from your local network for example to pre configure the SIP Ring Switch for a different ne...

Page 19: ...without signal and switched on in ON state By activating the inversion the output configured in this way acts exactly reversed Pulse mode By activating the Pulse Mode the output automatically returns...

Page 20: ...can also be done here Language Info In addition to the language selection German or English further display elements including the logo can be modified here Password The passwords for administrator an...

Page 21: ...utton the entered values are formally checked and the new key is generated The new CSR can be downloaded via the Download CSR button Self signed certificate A previously generated inidividual CSR can...

Page 22: ...is purpose SIP access must first be activated under Communication channels SIP To register in the system the following access data must be configured in the SIP basic settings area Telephone system IP...

Page 23: ...extension number Password Enter the password that is stored in the telephone system for the extensions repre sented by the SIP ring switch SIP type Choose here between PJSIP and SIP The added extensio...

Page 24: ...list and the desired phone numbers or connection IDs can then be marked and added to the subscriber inventory by clicking on the Save button Output access To determine which output is to be switched...

Page 25: ...d web pages Home The Home page provides an overview of the outputs and the configured actions With the appropriate login the outputs can be switched Both must first be enabled under Web sites Home By...

Page 26: ...gs are necessary in order to send email messages Network parameters If you want to send via a mail server on the Internet it is important that the basic network settings are correct Check under Basic...

Page 27: ...placed by the current IO states counter values etc when the e mail is sent Placeholder Description ox State of the outputs No x ON OFF cx Counter state No x o State of all outputs as hex bit pattern d...

Page 28: ...calls from a shared subscriber trigger the action Output Any output can be specified as an initiator For the output you can specify whether a change from OFF to ON a change from ON to OFF or any stat...

Page 29: ...ll hour every 15th minute and every 30th minute For example An action should be performed in the months of April to October every Monday at 8 00 a m Minute 0 Hour 8 Date Month 4 10 Day of week 1 Devic...

Page 30: ...P Ring Switch or Web IO Digital Also in this case either one specific output or several outputs can be switched Specify the IP address of the Device at which the outputs are to be switched Specify the...

Page 31: ...In addition to the actual message that is sent when the action is triggered a clear message can also be stored in the text messages The clear message is sent when the trigger for the action is no lon...

Page 32: ...rates as a TCP client When initiating the action it opens a TCP connection to the specified TCP server address on the specified port transmits the message or clear text and then immediately closes the...

Page 33: ...he supported commands and additional details on access via ASCII sockets can be found in the Web IO programming manual download at http www WuT de Follow the manual link on the data sheet page of Web...

Page 34: ...lt this access is blocked and must first be enabled using Communication paths Web API A detailed description of the supported HTTP requests and more details about access using Web techniques such as A...

Page 35: ...er are in the same network segment Read the Ethernet address of the SIP Ring Switch from the label at the side of the housing xxx Now use the following command line from the ARP table of the computer...

Page 36: ...ther power or the network connection during the update All the settings in the SIP Ring Switch are retained and the SIP Ring Switch should be immediately ready to use following the update Emergency ac...

Page 37: ...g Digital Outputs network min 1000 V Conections 1 x 11x screw terminal block for outputs and power 1 x RJ45 for network Displays Status LEDs for network Error LEDs for system and application 8 LEDs fo...

Page 38: ...38...

Page 39: ...39...

Page 40: ...40 Wiesemann Theis GmbH Porschestra e 12 D 42279 Wuppertal Mail info wut de Web www wut de Tel 49 0 202 2680 110 Fax 49 0 202 2680 265...

Reviews: