19
Basic settings
7. Basic settings
The further configuration of the SIP Ring Switch is done using a web browser. Enter
the IP address of the Web IO in the browser command line. In the navigation tree,
click
Login
and choose
Administrator
as user. By default, no password is assigned
and a click on the login button is sufficient to configure the SIP Ring Switch with
administrator rights.
Configuring the Outputs
In
Basic settings » Outputs
you can give individual names to the outputs. These
names replace the factory default names
Output n
in the visualization and any
message texts.
Expanded output settings
For special applications some output properties can be modified:
Inverted output characteristics
Normally the outputs are switched off in OFF state (i.e. without signal) and switched
on in ON state. By activating the inversion, the output configured in this way acts
exactly reversed.
Pulse mode
By activating the
Pulse Mode
, the output automatically returns to the OFF state after
the selected pulse duration when it is switched to the ON state. When switched
on again during the pulse, the pulse duration starts counting again.
Reset Allowed
specifies that the output may also be switched to the OFF state during a current
pulse.
Pulse mode (flashing signal)
For some signaling applications it is helpful if the signal is not switched permanent-
ly to ON or OFF state, but changes continuously between ON and OFF.
If a negative value is entered as pulse duration, the output falls back to OFF after
the specified time and automatically switches back to ON after four times the pulse
duration. If a pulse duration of e.g. -1000 is entered, the output remains switched on
for one second and then switches off for four seconds.