30
Integration into existing systems
Actions
Switching outputs
When switching outputs the SIP Ring Switch differentiates between switching its
own outputs or switching the outputs on another SIP Ring Switch.
Switching the own outputs
The outputs can be switched to ON or OFF. Another possibility is to toggle the exist-
ing state.
Alternatively, several outputs can be switched simultaneously. For each selected
output, you can specify whether it is to be set to ON or OFF.
Switching the outputs of another
SIP Ring Switch or Web-IO Digital
Also in this case, either one specific output or several outputs can be switched.
Specify the IP address of the Device at which the outputs are to be switched.
Specify the TCP port set as the browser access port for the destination Device. If
the target SIP Ring Switch or Web-IO is protected with a password, this must also be
entered.
For the destination Device
Allow HTTP requests
must be enabled (
Communication
paths » Web-API
) and the controlled outputs for switching from the browser and HTTP
must be enabled.
The outputs of the older Web-IOs models #57630, #57631, #57634 und #57637 can also
be switched. In this case the HTTP port of the Web-IO must be specified as the TCP port.