Configuration of the serial port
Subject to error and alteration
Models 58031, 58034, 58633, 58231, 58331, 58334
Divisor= 7,3728*10
6
16*Baudrate
Baudrate=
7,3728*10
6
16*Divisor
The currently configured baud rate is displayed when selecting
the submenu
SETUP Port x (serial)
r
UART Setup
.
By allowing any divisor, very high baud rates are possible.
Please note in this connection that the upper limit for a bundled
data stream is 230.4 kbps.
1
The indicated value refers to a handshake-controlled
half-duplex transmission with no parity and a non-loaded
network.
8.1.2 The handshake modes
(SETUP Port x
r
UART Setup
r
Handshake)
This menu provides three standard modes for flow control of
the serial port. As opposed to these predefined handshake
profiles, you can use the Special submenu to specify the
function of each control signal individually. This allows you for
example to use hardware-controlled TCP connection control.
Details on the control line functions are contained in the
description of the submenu.
n
Hardware Handshake
When using hardware handshake, the individual RS232
signals perform their factory-set functions as described in
the section „RS232 Interface“. Please note that the meaning
of the individual signals may be changed by the respective
user software.
Function of the control signal: RTS:
Flow Control
DTR:
Show Connection
CTS:
Flow Control
DSR:
NO
Summary of Contents for 58031
Page 8: ...W T ...
Page 38: ...38 W T Form factors ...
Page 102: ...102 W T The protocol stack of the Com Server ...
Page 128: ...128 W T The Windows COM redirector ...
Page 134: ...134 W T Box to Box mode ...
Page 152: ...152 W T Data transfer per Telnet ...
Page 192: ...192 W T Firmware update of the Com Server ...
Page 215: ...215 W T Appendix Subject to error and alteration Declaration of conformity ...