3
Sincerely appreciate your purchasing of Wannan Motor.
Please read the instruction carefully before usage so as to ensure that the motor is correctly used
and maintained.
Warning!
Be careful when carry the motor, otherwise strong falling, impact or
vibration will cause the bearing severe damaged. Fasten onto the lifting hook tightly
as the motor is moved by the crane.
1. Overview
This motor can be used in the circumstance of high altitude. The plateau code G1, G2, G3, G4, G5
can be sorted according to the applicable altitude of the motor:
Altitude Range
Plateau Code
Reference Model
1000
~
1999m
G1
Y2-112M-4-G1
2000
~
2999m
G2
Y2-112M-4-G2
3000
~
3999m
G3
Y2-112M-4-G3
4000
~
4999m
G4
Y2-112M-4-G4
5000
~
5999m
G5
Y2-112M-4-G5
2. Inspection
2.1 Check the appearance of the motor to see if there is outer damage or not and check nameplate
data like model, rated voltage, frequency etc. to see whether all is conform to actual requirement.
2.2 Rotate the motor shaft by hands to see whether the rotation is flexible and smooth (Tip: The
IP55 motors with frame style rubber oil seal rotate a little harder.)
2.3 Ensure that all parts in the motor are tightly and in good assembling.
2.4 Remove the terminal box cover, and measure the insulation resistance of the motor winding
with 500V Meg-ohmmeter. The value should be not less than 5MΩ. For the motor which has the
requirement of preventing dew, the user should keep the power at rated voltage passing through heat
for 30 minutes before the motor get start to operate, with the aim to ensure that there is no dew inside.
Notice:
Any question during inspection please contact us or consult the technician.
3. Installation
3.1 The motor should be installed by technicians. For the motor with feet, all the feet should be
fixed to the same plane that is sound and flat. If spacer must be added to the feet, these spacers should
be guaranteed not to be forced out during the installation and fastening. Coupling, gear, belt pulley can
be used for transmission.