INTRODUKTION
HANDLING
The product is delivered securely fastened on a pallet and must not be tipped off the pallet. When unloading the product,
use the lifting handles mounted on the chamber (Large) or alternatively, place slings around the chamber. The chamber
must be placed on a flat surface during storage.
INSTALLATION
The chamber must be installed at the same angle as the fall of the pipe placed in the sloping part of the pipe since the
product does not have built-in fall. Make sure that the flow direction of the chamber follows the flow direction of the pipe.
WaBack and WaBack Access should be installed as recommended according to the appropriate regulations in each
country. The bottom of the product should be placed at a frost-free depth or a frost guard or similar should be used so
that water does not freeze in the well.
EXTENDING THE HEIGHT OF THE CHAMBER
The height of the chamber is extended with the help of a Wavin riser DN425 or Wavin riser DN1000. Connect a Wavin
reducing cone to the DN1000 riser if a DN640 cover is required.
MANHOLE COVERS
There are different manhole covers available.
Load-bearing (cast iron manhole cover) or non-load-bearing manhole cover (plastic) in sizes DN425 or DN640.
GROUNDWATER PRESSURE
If there is a risk of groundwater pressure, the product must be firmly anchored to prevent floating. This applies to WaBack
Access Large. Use the handles on the product as anchoring points.
The maximum laying depth is 2.5 m from pipe invert to ground level.
RECYCLING
WaBack and WaBack Access Small/Large are made primarily of environmentally-friendly materials. Before disposing of the
product, separate the components for recycling. See the table for how the parts are recycled.
Stainless Steel**
PE*
EDPM*
Polyurethane*
Fasteners
Chamber
Elbow
Floatation arm
* Incinerate
** Metal recycling
OPTIONAL ACCESSORIES
ALARM
Wired and wireless water level alarms are available for purchase separately. The alarm ensures extra protection in the event
of raised water levels. The alarm senses when the water level is over the expected level and emits both a light and sound
signal. The alarm sensor should be mounted in the chamber and the receiver unit should be installed in a building, service
facility or similar. The connection for the wireless alarm between the sender and receiver must be tested before the alarm
is put into service to ensure the signal is not disturbed by any nearby building structure.
RISER
Wavin Tegra: WaBack Access Small DN425. WaBack DN600. WaBack Access Large DN1000
SHUT-OFF PLATE - ACCESS ONLY
The shut-off plate enables the product to function as a shut-off valve. This function enables the pipe to be closed off for
service and maintenance.
REDUCER
Tegra DN1000 Cone
MANHOLE COVER
Manhole cover: WaBack Access Small DN425, WaBack DN640, WaBack Access Large DN1000
Summary of Contents for WaBack DN110-200
Page 5: ...5 WABACK AND WABACK ACCESS SMALL INSTALLATION INSTRUCTIONS 6 7 8 5...
Page 8: ...8 WABACK MAINTENANCE 3 4 1 6 2 5 2 X YEAR OR AS REQUIRED...
Page 9: ...9 WABACK ACCESS SMALL MAINTENANCE 4 3 2 1 2 X YEAR OR AS REQUIRED...
Page 10: ...10 WABACK ACCESS LARGE INSTALLATION INSTRUCTIONS 2 1 4 3 5...
Page 11: ...11 5 WABACK ACCESS LARGE MAINTENANCE 3 4 1 2 6 2 X YEAR OR AS REQUIRED...