background image

4

WABACK AND WABACK ACCESS SMALL INSTALLATION INSTRUCTIONS

WABACK

3

4

1

(CLASS 2, TABLE C/1, MARK AMA)

24

2

WABACK ACCESS SMALL

X = OPENING PRESSURE x 1.25

Summary of Contents for WaBack DN110-200

Page 1: ...0 200 NPS 4 8 DN200 315 NPS 8 12 WaBack DN110 200 is CE approved according to the European standard for flood protection for buildings SS EN13564 1 2002 Type 1 Type 3 Please note your product serial n...

Page 2: ...NFORMATION 3 OPTIONAL ACCESSORIES 3 WABACK AND WABACK ACCESS SMALL INSTALLATION INSTRUCTIONS 4 5 EMERGENCY CLOSURE DEVICE INSTALLATION 6 7 WABACK MAINTENANCE INSTRUCTIONS 8 WABACK ACCESS SMALL MAINTEN...

Page 3: ...be firmly anchored to prevent floating This applies to WaBack Access Large Use the handles on the product as anchoring points The maximum laying depth is 2 5 m from pipe invert to ground level RECYCL...

Page 4: ...4 WABACK AND WABACK ACCESS SMALL INSTALLATION INSTRUCTIONS WABACK 3 4 1 CLASS 2 TABLE C 1 MARK AMA 2 4 2 WABACK ACCESS SMALL X OPENING PRESSURE x 1 25...

Page 5: ...5 WABACK AND WABACK ACCESS SMALL INSTALLATION INSTRUCTIONS 6 7 8 5...

Page 6: ...2 4 Attach the eyelet bolt 150 5mm from the bottom of the riser using the washer and nut included WaBack Standard only Attach the console 400mm 30mm from the top of the riser using the washers bolts a...

Page 7: ...7 6 WABACK EMERGENCY CLOSING 7 9 8 Attach the console 400mm 30mm from the top of the riser using the washers bolts and nuts included One washer on each side of the riser...

Page 8: ...8 WABACK MAINTENANCE 3 4 1 6 2 5 2 X YEAR OR AS REQUIRED...

Page 9: ...9 WABACK ACCESS SMALL MAINTENANCE 4 3 2 1 2 X YEAR OR AS REQUIRED...

Page 10: ...10 WABACK ACCESS LARGE INSTALLATION INSTRUCTIONS 2 1 4 3 5...

Page 11: ...11 5 WABACK ACCESS LARGE MAINTENANCE 3 4 1 2 6 2 X YEAR OR AS REQUIRED...

Page 12: ...12 WABACK ACCESS LARGE MAINTENANCE 8 7...

Page 13: ...P WABACK NON RETURN VALVE ENGLISH GUARANTEE Wapro AB shall remedy defects in the Product resulting from material and or workmanship for a period of two 2 years from the original date of purchase and a...

Page 14: ...10 minutter Testen ansees som godkjent hvis lekkasjen ikke overskrider 500 cm3 etter ha oppn dd tilbakeslagstrykket DANSK WABACK TILBAGEL BSSTOP GARANTI Wapro AB skal afhj lpe erstatte de fejlbeh fte...

Page 15: ...winien trwa 10minut Test powinien zosta uznany je li wyciek wody nie bedzie wi kszy ni 500 cm3 po osi gni ciu odp ywu nale y utrzyma zwi kszone ci nienie WABACK STUDZIENKA PRZECIWCOFKOWA Z WBUDOWANYM...

Page 16: ...OLDING BACK THE FLOOD Wapro AB Munkahusv gen 103 SE 374 31 Karlshamn Sweden Tel 46 454 185 10 Email wapro wapro com Wapro solutions protect against stormwater and backflow flooding Protecting people a...

Reviews: