General information

Fig.1    Cutoff relays 

The cutoff relay is a contact multiplier that makes it possi-

ble to simultaneously operate two (or more in a series) sun 

shading drives using a single operating element (switch) or 

via the output of a single motor control unit. The drives are 

supplied via a separate outside line (phase). The cutoff relay 

is equipped with terminals for connecting the lines, making 

it possible to form larger drive groups that can be controlled 

globally. Because of its compact design, the cutoff relay can 

be mounted in a flush-mounted junction box.

Intended use

The device was developed to control sun shading sys-

tems. The approval of the manufacturer must be obtained 

for uses outside of the purposes listed in these instruc-

tions.

Safety instructions

WARNING

The electrical installation must be per-

formed by a certified electrician in accord-

ance with the electrical installation regu-

lations published by the Association of 

German Electrical Engineers (VDE 0100) 

or the standards and regulations of the 

country. The specialist must observe the 

installation instructions included with the 

electrical device.

WARNING

If hazard-free operation cannot be as-

sumed, the device may not be started or 

must be deactivated. This assumption is 

justified

 

  

If the housing or the supply lines show signs 

of damage, 

 

 

The device is no longer working.

WARNING

It is important to comply with the follow-

ing instructions in the interest of personal 

safety.

 

 

Do not allow children to play with the operating ele-

ments of the control or remote control. Store the re-

mote controls out of reach of children.

 

 

Make sure that no persons or objects are in the range 

of movement of the driven parts (blinds, window, etc.).

 

 

Disconnect the device from the supply voltage if clean-

ing or other maintenance work must be performed.

Information on the electrical installation

An on-site overload current protection device (fuse) and a 

disconnecting and isolating switch to switch off the entire 

system must be provided.

The device meets the EMC directives for use in residential 

and commercial areas.

Installation

The cutoff relay is intended for installation in a flush-mount-

ed junction box ∅70 mm. 

 

 

Only such lines as are used for the wiring of the re-

ceiver should be routed into this box. 

The unit is electrically connected according to the wiring 

diagram on the reverse.

Handling the spring terminals

Fig. 2    Connecting and disconnecting the line connections

After the wire is stripped, it is pressed into the terminal (1) 

until the insulation on the wire enters the terminal and the 

line is securely held in the terminal (2). To disconnect the 

line, the appropriate unlock button needs to be pressed in 

as far as it will go using a screw driver, and the line then 

removed from the terminal (3).

Commissioning

The device is operational after the installation has been 

completed and the supply voltage applied.