background image

Operation/care/maintenance 

[B867400_1] - EN / 20.07.11 

Page 9 of 16 

Subject to change without notice 

Projection area: Risk of crushing/injury 

 

 

 

Always keep the 
projection area of the 
external venetian blind 
clear of obstacles. 

 

If the unit hits an 
obstacle after all, the 
blind first needs to be 
raised slightly before 
the obstacle is re-
moved. 

 

Keep people away from 
the external venetian 
blind as long as the 
product is moving! 

Products with electrical 
control units may start 
moving at any time and 
without prior notice. Ensure 
that dangerous situations 
do not arise. 

 

 

Do not reach in 
between movable parts 
(e.g. bottom rail and 
slat). 

The product can be 
controlled manually (via the 
operating element) or 
automatically (via the 
control). When the product 
is raised, the slats arrange 
themselves on top of each 
other into a package. If 
parts of the body (hands, 
for example) are located 
between the slats, there is 
a risk that the person will 
be pulled upward together 
with the package. 

 

4

 

Care/maintenance 

4.1

 

General information on care and 
maintenance 

Regular appropriate care and maintenance and the 
exclusive use of original spare parts are essential for 
trouble-free operation and a long product lifetime. 

 

NOTE 

Ensure that the external venetian blind is not 
moved during maintenance and repair work in its 
direct proximity – e.g. window-cleaning. 

A monitored, overriding locking mechanism must 
prevent every kind of operation. 

 
 

WARNING 

Risk of injury and product damage from 
operation of the external venetian blind 
when it is out of sight. 

 

De-energise and lock out the 
external venetian blinds. 

 

Do not operate external venetian 
blinds during maintenance and 
cleaning work. 

 

Disconnect the external venetian 
blinds from the automatic control 
and/or power supply. 

 
 

DANGER 

Risk of injury and falling! 

 

Do not rest climbing aids against the 
product. 

 

Climbing equipment must rest on a solid 
foundation and offer good support! 

 
 

Summary of Contents for C 80 A8

Page 1: ...WAREMA metal system venetian blinds Type C E 80 90 93 A8 Instructions for use and maintenance To be handed over to the operator Valid from 20 July 2010 Document number B867400_1 EN...

Page 2: ...ormation 5 2 1 Parts description 5 2 2 Technical data accessories 5 2 3 Intended use 5 2 4 Wind speed limits 6 2 5 CE conformity 6 3 Operation 7 3 1 Operation with the crank 7 3 2 Operating the extern...

Page 3: ...eration Ot ealt with Page 3 of 16 the ese t in e to A of in ully ou he nd ate tain nte tem ther Pe No na as app pro sol WA ref use 1 3 Sa app S ermissible act o other altera nce work are t described i...

Page 4: ...venetian blinds to the upper limit position and take them out of service We recommend the use of an ice monitoring system Raise the external venetian blinds to the upper limit position and take out o...

Page 5: ...for their intended use to provide privacy and protect against summer heat and glare Inappropriate use may result in significant danger The metal system venetian blinds are raised and lowered by a lif...

Page 6: ...mounting ven due to the 5 CE co E conformity rresponding ndition and en e obliged to aintenance Name Year of Head office Standa Produc tended use Wind class oise emission Specification stands cann ar...

Page 7: ...g the external venetian blind drive Lowering using the sunblind push button venetian blind switch To lower the external venetian blind Press the DOWN button and hold if nec essary or Turn the toggle s...

Page 8: ...al control unit to manual if you are going to be away NOTE Adjust the central control unit in such a way that continuous operation of the motor is avoided The motors used in these products are not int...

Page 9: ...xample are located between the slats there is a risk that the person will be pulled upward together with the package 4 Care maintenance 4 1 General information on care and maintenance Regular appropri...

Page 10: ...orrosion Do not use chlorinated cleaning agents on or near the product Ensure that water does not penetrate into the top rail Water can lead to functional problems and short circuits Do not support yo...

Page 11: ...de energised and locked out Check the function and the limit positions of the external venetian blinds Check the external venetian blinds for visible wear for damage to the motor line and to ensure t...

Page 12: ...product operates properly on a continuous basis and to avoid changing its approved status use WAREMA spare parts only Contact a qualified specialist for further information if necessary 7 Dismantling...

Page 13: ...t as per wiring diagram certified electricians only Motor thermal protection switch has triggered Wait 10 to 15 minutes then try again There is no current Check the power fuse certified electricians o...

Page 14: ...crews qualified specialists only Loose locking screws Tighten the fixing screw specialists only Crank rod is difficult or impossible to turn Mechanism is blocked or defective Replace the gear drive sp...

Page 15: ...B867400_1 EN 20 07 11 Page 15 of 16 Subject to change without notice...

Page 16: ...WAREMA Renkhoff SE Hans Wilhelm Renkhoff Stra e 2 97828 Marktheidenfeld Germany www warema de info warema de...