Product information
In winds over 48 m/s, the slats must be closed. With the
slats closed, the WAREMA slat roof is designed for a wind
load of 1.1 kN/m².
2.5
Wind resistance Integrated awning with
easyZIP guidance (optional)
The product has the following wind
resistance rating: class 3
INFO
Due to their design, integrated awnings with
easyZIP guidance withstand markedly higher wind
speeds when lowered than when moving in the
DOWN direction.
The supplied product features a new motor with
a responsive obstacle detection mechanism. The
motor is capable of detecting an excessive wind load
while the product is being extended, which means
that the product can be stopped before damage can
result.
When using a wind sensor (WAREMA
recommendation), the wind sensor
must
be set
to one level lower than specified in the respective
model (
Example: order height
≤
2500 mm and total width
≤
4000 mm - set value to 10 m/s
Order height in [mm]
Width in
[mm]
Up to
1000
Up to
1500
Up to
2000
Up to
2500
Up to
3000
Up to
1000
24
24
24
21
21
Up to
1500
24
24
21
17
17
Up to
2000
24
21
17
17
13
Up to
2500
21
17
17
13
13
Up to
3000
21
17
13
13
13
Up to
3500
21
17
13
13
13
Up to
4000
21
17
13
13
13
Up to
4500
21
17
13
13
13
Up to
5000
21
17
13
13
13
Up to
5500
17
17
13
13
13
Up to
6000
17
17
13
13
10
Tab. 5:
Wind speed limits for integrated awnings
with easyZIP guidance (details in m/s)
The table values (Beaufort numbers) should be changed in
the following cases:
1 Movement
– Lower
Reduce value by 1
2.6
Resistance against water collection (slat
roof)
The product fulfils performance class 2 in accordance with
DIN EN 13561.
Performance class 2 is equivalent to precipitation of 56 l/m²
per hour.
The product offers protection against the weather when the
slats are closed.
2.7
Slat roof snow load
Lamaxa slat roofs with sizes up to 6x4.5 m have a
permissible snow load of max. 50 kg/m² when closed. If the
construction limit value of 6x4.5 m is exceeded, the snow
load is limited to 45 kg/m².
To prevent the slat roof becoming overloaded, WAREMA
recommends moving the slats into an open, middle slat
position (90°) when snow starts to fall.
If the slat roof is subjected to a snow load when the slats
are closed, the user must avoid loads greater than the
above-specified loads of 45 and 50 kg/m² by clearing the
snow, for example.
3
Operation
INFO
Only operate the product if it is in technically
perfect condition.
Do not operate a product if it is damaged. Always
contact the specialist dealer and protect the
product against being operated as agreed with
the specialist.
Page 8 | 32
2029839 [Rev. 9 - en]/2021-10-11