Maintenance

There are no parts within the device that require 

maintenance.

Cleaning

The weather station should occasionally be checked for 

dirt (e.g. bird droppings) and cleaned carefully. Clean the 

housing with a soft, damp cloth. Do not use detergents, 

cleaning agents, solvents, abrasive substances or steam 

cleaners!

Liability

Failure to comply with the product information in these 

instructions and any use of the device other than its 

intended use may result in the manufacturer refusing to 

honour warranty claims for product damage. In this case, 

liability for secondary harm to persons or damage to 

property will also be excluded. Observe the information in 

the operating instructions for your sun shading system. The 

automatic or manual operation of the sun shading system 

while iced over and the use of the sun shading system 

during severe weather may cause damage and must be 

prevented by the operator through suitable precautions.

Obligations for the disposal of electrical 

devices 

A marking with this symbol indicates the following 

obligations under the scope of legal regulations:

 

 

The owner of this electrical device must dispose of it 

separately from unsorted municipal waste for further 

recycling.

 

 

Used batteries and accumulators that are not enclosed 

in the old device, as well as lamps/bulbs that can be 

removed from the old device without breaking, must be 

disposed of separately.

 

 

Distributors of electrical devices and disposal 

companies are obliged to take back the equipment free 

of charge.

 

 

The owner must take it upon themselves to delete any 

personal data contained in the electrical device prior to 

disposal.

Technical data

Omnexo Weather station 

move

min. type max. Unit

Supply

Operating voltage (SELV)

21.6

24

26.4

V DC

Current consumption

30

100

mA

Temperature sensor*

Measuring range

-20

60

°C

Resolution

0.5

°C

Accuracy

±2

°C

4 direction-dependent photo sensors

Measuring range

0

 

100

klx

Resolution

1

klx

Accuracy

±10

%

Dawn/dusk measuring range

0

500

lx

Resolution at dawn/dusk

1

lx

Accuracy at dawn/dusk

±10

%

Wind speed

Measuring range

0

25

m/s

Resolution

1

m/s

Accuracy

±1

m/s

Omnexo Weather station 

move

min. type max. Unit

Precipitation sensor

Measuring range

Precipitation yes/no

Omnexo interface

Bus interface

RS485 (two-wire bus)

Housing

Dimensions

130 ×175 ×130 mm (WxHxD)

Degree of protection 

IP 43

Safety class

III

Installation

Wall/pole

Miscellaneous

Conformity

 

Can be viewed at  

www.warema.de/ce

This device complies with the EMC directives for use in 

residential and commercial areas.
Software class

A

Ambient conditions

Operating temperature

-30

60

°C

Storage temperature

0

70

°C

Humidity

(not condensing)

10

100

%RH

Degree of soiling

2

Connection

Omnexo interface

Screw terminal

Permissible line cross-section 

single-wire/fine-wire without 

ferrule

0.14 - 1.5 mm²

Permissible line cross-section 

fine-wire with ferrule

0.14 - 0.75 mm²

Stripping length

7 mm

Maximum line length

10 m

Recommended line type  

for outdoors

4 x AWG 26 C UL (resistant to 

UV rays)

Article numbers

Omnexo Weather station move

2047094

Optional accessories

Omnexo Weather station 

pro power supply unit 24 V 

DC/1.3 A AP

2057430

Connecting line 4 x AWG  

26 C UL (resistant to UV rays) 

3 m

634277

Connecting line 4 x AWG  

26 C UL (resistant to UV rays) 

10 m

634288

Pole L = 35 cm; 

Dia. 20 mm, wall mounting, wall 

distance 150 mm

632075

Pole L = 100 cm;

Dia. 20 mm, wall mounting, wall 

distance 150 mm

632085

Adapter for pole

Dia. 50 mm

632095

WAREMA Renkhoff SE 

Hans-Wilhelm-Renkhoff-Strasse 2 

D-97828 Marktheidenfeld, Germany

Germany

*  

Temperature measuring value: 

 

To obtain correct and highly accurate measuring values, 

the weather station must be installed in direct sunlight.  

Therefore, when the sun is shining brightly, the 

temperature values measured with other thermometers in 

the shade may differ from the values measured here.  

This deviation has no effect when you use the ice 

monitoring function in a network user.

Summary of Contents for Omnexo Weather station move

Page 1: ...ed angle to allow the water to drain off the sensor surface Installation Install the weather station using the mounting bracket provided The weather station must be mounted in an upright position with a maximum inclination of 2 The photodiodes must be at right angles to the building facades being shaded General information Fig 1 Omnexo Weather station move The Omnexo Weather station move collects ...

Page 2: ...l control unit as per wiring diagram Fig 4 on page 4 The bus lines must be provided with terminating resistors at the beginning and end of the line HUBs are needed for longer line lengths If you are using the optional Omnexo Weather station pro power supply unit 24 V DC 1 3 A AP article number 2057430 a branch line of max 10 m to the Omnexo Weather station move is permissible Please take out the W...

Page 3: ...ng range 20 60 C Resolution 0 5 C Accuracy 2 C 4 direction dependent photo sensors Measuring range 0 100 klx Resolution 1 klx Accuracy 10 Dawn dusk measuring range 0 500 lx Resolution at dawn dusk 1 lx Accuracy at dawn dusk 10 Wind speed Measuring range 0 25 m s Resolution 1 m s Accuracy 1 m s Omnexo Weather station move min type max Unit Precipitation sensor Measuring range Precipitation yes no O...

Page 4: ...type label on the right hand side as seen from the front The status LED lights up as a confirmation Magnet Fig 3 Omnexo Weather station move and magnet dimensions for commissioning 4 x AWG 26 UL black JY St Y 4 x 2 x 0 8 mm junction box on site Omnexo Central control unit 1 2 3 4 terminal 1 0 V terminal 2 24 V terminal 3 A terminal 4 B View from below Strain relief WH OG YE BN BK RD BK RD O G B N ...