3
warema_2052443_alhb_en_v3•2023-07-01
We reserve the right to make technical modifications
Maintenance
There are no parts within the device that require
maintenance.
Cleaning
The weather station should occasionally be checked for
dirt (e.g. bird droppings) and cleaned carefully. Clean the
housing with a soft, damp cloth. Do not use detergents,
cleaning agents, solvents, abrasive substances or steam
cleaners!
Liability
Failure to comply with the product information in these
instructions and any use of the device other than its
intended use may result in the manufacturer refusing to
honour warranty claims for product damage. In this case,
liability for secondary harm to persons or damage to
property will also be excluded. Observe the information in
the operating instructions for your sun shading system. The
automatic or manual operation of the sun shading system
while iced over and the use of the sun shading system
during severe weather may cause damage and must be
prevented by the operator through suitable precautions.
Obligations for the disposal of electrical
devices
A marking with this symbol indicates the following
obligations under the scope of legal regulations:
The owner of this electrical device must dispose of it
separately from unsorted municipal waste for further
recycling.
Used batteries and accumulators that are not enclosed
in the old device, as well as lamps/bulbs that can be
removed from the old device without breaking, must be
disposed of separately.
Distributors of electrical devices and disposal
companies are obliged to take back the equipment free
of charge.
The owner must take it upon themselves to delete any
personal data contained in the electrical device prior to
disposal.
Technical data
Omnexo Weather station
move
min. type max. Unit
Supply
Operating voltage (SELV)
21.6
24
26.4
V DC
Current consumption
30
100
mA
Temperature sensor*
Measuring range
-20
60
°C
Resolution
0.5
°C
Accuracy
±2
°C
4 direction-dependent photo sensors
Measuring range
0
100
klx
Resolution
1
klx
Accuracy
±10
%
Dawn/dusk measuring range
0
500
lx
Resolution at dawn/dusk
1
lx
Accuracy at dawn/dusk
±10
%
Wind speed
Measuring range
0
25
m/s
Resolution
1
m/s
Accuracy
±1
m/s
Omnexo Weather station
move
min. type max. Unit
Precipitation sensor
Measuring range
Precipitation yes/no
Omnexo interface
Bus interface
RS485 (two-wire bus)
Housing
Dimensions
130 ×175 ×130 mm (WxHxD)
Degree of protection
IP 43
Safety class
III
Installation
Wall/pole
Miscellaneous
Conformity
Can be viewed at
www.warema.de/ce
This device complies with the EMC directives for use in
residential and commercial areas.
Software class
A
Ambient conditions
Operating temperature
-30
60
°C
Storage temperature
0
70
°C
Humidity
(not condensing)
10
100
%RH
Degree of soiling
2
Connection
Omnexo interface
Screw terminal
Permissible line cross-section
single-wire/fine-wire without
ferrule
0.14 - 1.5 mm²
Permissible line cross-section
fine-wire with ferrule
0.14 - 0.75 mm²
Stripping length
7 mm
Maximum line length
10 m
Recommended line type
for outdoors
4 x AWG 26 C UL (resistant to
UV rays)
Article numbers
Omnexo Weather station move
2047094
Optional accessories
Omnexo Weather station
pro power supply unit 24 V
DC/1.3 A AP
2057430
Connecting line 4 x AWG
26 C UL (resistant to UV rays)
3 m
634277
Connecting line 4 x AWG
26 C UL (resistant to UV rays)
10 m
634288
Pole L = 35 cm;
Dia. 20 mm, wall mounting, wall
distance 150 mm
632075
Pole L = 100 cm;
Dia. 20 mm, wall mounting, wall
distance 150 mm
632085
Adapter for pole
Dia. 50 mm
632095
WAREMA Renkhoff SE
Hans-Wilhelm-Renkhoff-Strasse 2
D-97828 Marktheidenfeld, Germany
Germany
*
Temperature measuring value:
To obtain correct and highly accurate measuring values,
the weather station must be installed in direct sunlight.
Therefore, when the sun is shining brightly, the
temperature values measured with other thermometers in
the shade may differ from the values measured here.
This deviation has no effect when you use the ice
monitoring function in a network user.