890362_b•en•21.03.2011
We reserve the right to carry out improvements
49
7.4 Humidity control
If you wish to control the humidity in your building or conservatory, for exam-
ple to create an appropriate climate for your plants, the Quatronic dialogue
provides a humidity sensor and connectivity for this purpose. For example,
you can use it to connect a roof window or fan. On the basis of the limit
value, the Quatronic dialog can then open and close the window or switch
the fan on and off. To connect devices that are unrelated to sun shading
products, contact your specialist for sun shading products.
If the humidity exceeds the DOWN limit value, the humidity control triggers a
DOWN move command.
The display then changes to
Position
and
Cause
.
Position:
Upper Upper
Cause: rel.H Rain Rain rel.H
The following display appears after the move command is completed:
Position: Lower Upper Upper Lower
Cause: rel.H Rain Rain rel.H
If the humidity drops below the UP limit value, the humidity control triggers
an UP move command.
An
appears in the display for the duration of the UP run time and Upper ap-
pears after the run time has expired.
7.4.1 Setting the humidity
control
The following parameters can be set for the humidity control:
Lim.
= Limit value for the "Up" move command
Lim.
= Limit value for the "Down" move command
Alloc
= Humidity sensor allocation for each facade
Keep the
disp/prog
button pressed for approx. 5 seconds.
Wind speed: 8m/s 8m/s 8m/s 8m/s
Time: 10:26:47 Wednesday, 20.11.2008
The selection menu is displayed:
Select the Wind RunT Timer Sun
settings: Rain Temp Product -->
Press the
button under
-->
to open the second page of the selection
menu.
omfort functions
Humidity control