WAREMA Quatronic dialog
®
Operating instructions
Select the Displ Ice ComfT Time
settings: Passw Da/Du Rel.H. -->
Press the
button below the word
Rel.H.
The
Rel. Humidity
menu is displayed:
Rel. Humidity Lim.
Alloc
control settings:Lim.
Select the desired parameter by pressing the
or
button.
Example
UP limit value
Lim.
In this menu, you can change the settings for each facade (
F1
-
F4
) using the
/
buttons.
Rel. humidity OFF OFF OFF OFF
Limit UP
: CH1 CH2 CH3 CH4
The
OFF
setting is achieved by setting the value to
0%
. The word
OFF
appears
instead of
0%
. This switches off the humidity control at the respective facade.
Leave the menu after completing the entries using the
disp/prog
button.
This saves the changes you made.
7.4.2 AP/ OWA limit value,
allocation
The effects of the settings are addressed below in more detail.
If the relative humidity reading exceeds the DOWN limit value, the sun shad-
ing product moves to the lower limit position.
If the relative humidity reading drops below the UP limit value, the sun shad-
ing product moves to the upper limit position.
Up to 4 humidity sensors can be connected to the Quatronic dialog. These
sensors are allocated to the 4 facades in the
Alloc
menu.
omfort functions
Humidity control