890362_b•en•21.03.2011
We reserve the right to carry out improvements
53
7.6 omfort timer
In some cases, the comfort functions are not ideal for your particular require-
ments. This usually occurs in non-standard applications.
Example
On one of the facades of your building, normal lighting, as it occurs on the
other facades, only takes place between 11:00 and 15:00; otherwise, this
"problem facade" is shaded by trees or a neighbouring building.
The sun shading products should not be moved on weekends.
The sun shading products should only be controlled on the basis of the in-
side temperature or sunlight in the mornings because the room is not used
in the afternoon.
And so on...
To be able to solve these types of problems with the Quatronic dialog, it
provides a comfort timer feature. This feature lets you control all comfort
functions on the basis of the time of day. You can also differentiate between
weekdays and weekends.
If you need to switch off the comfort functions temporarily, such as during a
garden party, while you are on holiday, when cleaning, etc., you can also glo-
bally switch off the automatic functions by hand.
Function of the comfort timer
Humidity
control
Sun
control
control
Dawn/dusk
Comfort function
On
Off
Inside temperature
control
Outside temperature
control
7:15
16:38
Switches all
comfort functions
off manually
Time switch
Works
independently
of the
comfort timer
On
Off
Switches the automatic functions on and off via the limit value setting
Switches the automatic functions on and off via a confirmation in the menu
Control timer
Switches the
comfort functions
on and off as a
function of time.
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
omfort functions
omfort timer