890362_b•en•21.03.2011
We reserve the right to carry out improvements
55
Comfort timer 6:30 OFF OFF OFF
ENABLE Mon-Fri: CH1 CH2 CH3 CH4
The
OFF
setting is achieved by setting the value to
00:00
. The word
OFF
ap-
pears instead of
00:00
. This switches off the comfort timer at the respective
facade.
Leave the menu after completing the entries using the
disp/prog
button.
This saves the changes you made.
7.6.2 MoFrE, MoFr , SaSuE,
SaSu
The sun control, humidity control and temperature control comfort functions
operate independently of the time of day. Thus, they also operate at night.
Using the comfort timer, you can deactivate these functions at any time by
entering the required time period.
(
MoFrE
,
SaSuE
)
Using the "Comfort functions ON on a weekday” (
MoFrE
) and "Comfort func-
tions ON on a weekend” (
SaSuE
) limit values, you can enter the times during
which the comfort timer should enable the comfort functions.
(
MoFrD
,
SaSuD
)
Using the "Comfort functions OFF on a weekday” (
MoFrD)
and "Comfort func-
tions OFF on a weekend” (
SaSuD
limit values, you can enter the times during
which the comfort timer should disable the comfort functions.
ynamic function: dawn,
dusk
The control of the comfort timer via time is rigid. However, you can also con-
trol the comfort timer "dynamically", i.e. using dawn/dusk.
Instead of a time, you can enter
Dawn
or
Dusk
. With this setting, the comfort
timer enables the comfort functions at dawn and disables them again at
dusk. This occurs earlier in the summer and later in the winter.
Setting the
Dawn
value
You obtain the
Dawn
setting by setting a time of
23:59
in the
MoFrE
and
SaSuE
menu items.
Dawn
appears instead of the time.
Setting the "Dusk" value
You obtain the
Dusk
setting by setting a time of
23:59
in the
MoFrD
and
SaSuD
menu items.
Dusk
appears instead of this time.
omfort functions