890362_b•en•21.03.2011
We reserve the right to carry out improvements
61
8.2.3 Turn time
The automatic turning control activates a brief (0.1 - 9.9 s) UP command (=
turn time) after the sun shading products have reached the lower limit posi-
tion. Whether or not the turning is actually executed depends on what caused
the DOWN command. See
Chapter 8.2.4
.
NOTE
If the set
DOWN
run time is longer than the actual product run time, the sun
shading products remain in the lower limit position until the turning takes
place.
When using the
External venetian blind
or
Pleated blind
product set-
ting, the turn setting can be used to set a slat angle of your choice. The turn
time can also be used to open roller shutters being used as a sun shading
system by a crack after they are lowered.
8.2.4 Turn mode
Whether or not the turning is actually executed depends what caused the
DOWN command. The causes that can be programmed are manual, sun and
time switch control.
These causes can also be combined:
M
Manual
S
Sun
T
Time search control
M/S
Manual/sun
M/T
Manual/time switch control
S/T
Sun/time switch control
M/S/T
Manual/sun/time switch control
OFF
OFF
General parameters
Run time and turn time