Step 1:
Turn jar upside down
and place retainer wrench into
position as shown.
Step 2:
Hold jar handle
firmly with one hand. With the
other hand, turn retainer wrench
counterclockwise to loosen the
retainer ring. CAUTION: ONCE NUT
IS REMOVED, BLADE ASSEMBLY
MAY FALL OUT OF THE JAR. BEFORE
PERFORMING STEP 3, ENSURE THAT
THE JAR IS ON A FULLY COVERED
FLAT SURFACE, AND THE BLADE
WILL NOT BE ABLE TO FALL AND
HIT A BODY PART OR ANYTHING
VALUABLE.
Step 3:
Fully remove retainer
ring as seen in image B. If the blade
assembly does not fall from the jar,
push down on the drive/bearing
assembly so it falls out of the jar
onto your working surface. You may
need to lightly tap on the assembly
with the bottom end of wrench to
disengage from the jar.
Step 4:
Discard the old
blending assembly and remove the
replacement blending assembly from
its package. Place jar on its side so
you can access both the top and
bottom of the jar easily.
Step 5:
Place jar on its side
so you can access both the top and
bottom of the jar easily. Wearing
A
E
H
B
C
D
heavy-duty gloves, place the new
blending assembly down through
the top of the jar (image C), aligning
the flats, and push bearing assembly
through the hole at the jar’s base
(image D).
Step 6:
On the underside
of the retainer ring you will notice
a small round rubber gasket
(image E). This side will be secured
against the bottom of the jar for
sealing. If the gasket was removed
for any reason, ensure it is properly
fixed into position (Image F). The
integrity of the seal on the jar relies
on this gasket. The jar may leak if
the gasket is missing or improperly
positioned (Image G). The new blade
assembly should be in the same
position as the old one.
Step 7:
With gloved hand,
hold blade assembly in place and
ensure it is completely pushed
through the jar hole. With the other
hand, take the retainer ring and wind
it down the threads on the bottom of
the new bearing assembly as seen
in image H You will need to use the
retainer ring wrench to tighten the
nut clockwise onto the assembly.
Step 8:
Ensure the nut is
tightened as firmly as possible and
the blending assembly is properly
fixed in place.
Troubleshooting
Resetting Thermal Protection
• Blender is equipped with an automatic reset function to protect the motor from overheating.
• If your blender stops running under heavy use, turn the power switch to OFF and unplug the power cord.
Empty the blender container of all its contents and allow between 5 and 30 minutes for the motor to cool down.
• Plug the power cord back into the outlet, refill blender container and continue blending.
• If your blender does not function properly following this procedure, discontinue use and contact
a certified Waring Customer Service Center or call customer service at 1-800-4WARING.
F
G
CAUTION: Blade is very sharp. Wear heavy-duty gloves during blade replacement.
MX Blender Blade Assembly Replacement