Step 1:

 

Turn jar upside down 

and place retainer wrench into 
position as shown.

Step 2:

 

Hold jar handle 

firmly with one hand. With the 
other hand, turn retainer wrench 
counterclockwise to loosen the 
retainer ring. CAUTION: ONCE NUT 
IS REMOVED, BLADE ASSEMBLY 
MAY FALL OUT OF THE JAR. BEFORE 
PERFORMING STEP 3, ENSURE THAT 
THE JAR IS ON A FULLY COVERED 
FLAT SURFACE, AND THE BLADE 
WILL NOT BE ABLE TO FALL AND 
HIT A BODY PART OR ANYTHING 
VALUABLE.

Step 3:

 

Fully remove retainer 

ring as seen in image B. If the blade 
assembly does not fall from the jar, 
push down on the drive/bearing 
assembly so it falls out of the jar 
onto your working surface. You may 
need to lightly tap on the assembly 
with the bottom end of wrench to 
disengage from the jar.

Step 4:

 

Discard the old 

blending assembly and remove the 
replacement blending assembly from 
its package. Place jar on its side so 
you can access both the top and 
bottom of the jar easily.

Step 5:

 

Place jar on its side 

so you can access both the top and 
bottom of the jar easily. Wearing 

A

E

H

B

C

D

heavy-duty gloves, place the new 
blending assembly down through 
the top of the jar (image C), aligning 
the flats, and push bearing assembly 
through the hole at the jar’s base 
(image D).

Step 6:

 

On the underside  

of the retainer ring you will notice  
a small round rubber gasket  
(image E). This side will be secured 
against the bottom of the jar for 
sealing. If the gasket was removed 
for any reason, ensure it is properly 
fixed into position (Image F). The 
integrity of the seal on the jar relies 
on this gasket. The jar may leak if 
the gasket is missing or improperly 
positioned (Image G). The new blade 
assembly should be in the same 
position as the old one.

Step 7:

 

With gloved hand, 

hold blade assembly in place and 
ensure it is completely pushed 
through the jar hole. With the other 
hand, take the retainer ring and wind 
it down the threads on the bottom of 
the new bearing assembly as seen 
in image H You will need to use the 
retainer ring wrench to tighten the 
nut clockwise onto the assembly.

Step 8:

 

Ensure the nut is 

tightened as firmly as possible and 
the blending assembly is properly 
fixed in place.

Troubleshooting

Resetting Thermal Protection
•  Blender is equipped with an automatic reset function to protect the motor from overheating.
•  If your blender stops running under heavy use, turn the power switch to OFF and unplug the power cord.  

Empty the blender container of all its contents and allow between 5 and 30 minutes for the motor to cool down.

•  Plug the power cord back into the outlet, refill blender container and continue blending.
•  If your blender does not function properly following this procedure, discontinue use and contact  

a certified Waring Customer Service Center or call customer service at 1-800-4WARING.

F

G

CAUTION: Blade is very sharp. Wear heavy-duty gloves during blade replacement.

MX Blender Blade Assembly Replacement