Warmsource-N/P: Installation
SECURING WARMSOURCE-N/P
f
Double check code clearances and minimum
clearance dimensions (
page 5
)
f
Fasten the mounting bracket to the wall
(The installation of two, 2"x 4"x18" wood sleepers
may be necessary. Securely fasten the sleepers
to the wall studs, then mount the bracket to
the sleepers)
f
Once the bracket is secured, lift Warmsource-N/P
on to the mounting bracket (the unit weighs 150lbs
and requires two individuals to move safely)
CONNECTIONS
f
Connect the PVC intake and exhaust lines, gas line,
condensation discharge line and T&P relief discharge
line per the HTP Manual
f
Plumb the cold water line to the backflow
preventer and the pressure reducing valve
(
see WCS Design Drawings
)
f
Install all 1
1/4
" copper plumbing and primary
distribution lines
f
Install the Warmboard-supplied, dark grey, 6" x 3"
CPVC pipe to the exhaust gas vent (
see photo
)
f
Install the condensate neutralizer
(
see HTP Manual, page 40
)
Warmsource-N/P is top heavy and weighs
150lbs. Use two people to lift and carry.