Page
48
5.4.3 I-Series (Internal) Pumped, Pumped Professional
MODEL
I21P / I21P PRO
I26P / I26P PRO
I33P / I33P PRO
I44P
Nominal
Heat Output
kW
Btu/hr
14.7
50,000
17.6
60,000
21.0
71,650
21.0
71,560
23.5
80,000
27.1
92,380
27.1
92,380
29.0
99,050
32.7
111,600
33
112,629
38.5
131,362
44
150,128
Nominal
Heat Input
kW
Btu/hr
15.3
52,150
18.4
62,600
22.0
75,000
22.0
75,000
24.4
83,175
28.0
95,550
28.0
95,550
30.0
102,400
34.0
116,000
33
112,629
40
136,139
46.8
159,681
Burner
RDB 2.2 BX 15-21
RDB 2.2 BX 21-27
RDB 2.2 BX 27-33
RDB 3.2 BX 33-44
Head
BX500
BX700
BX700
BX700
Secondary Air Damper
B
N/A
N/A
N/A
Conventional
Flue Diameter
mm
in
100 or 125
4 or 5
100 or 125
4 or 5
100 or 125
4 or 5
100 or 125
4 or 5
Flue Gas Temp.
0
C
86
88
90
90
93
95
95
98
110
75
90
105
Smoke
Bacarach
0
0
0
0
Kerosene Settings
Nozzle
make
Danfoss 80°EH
Danfoss 80°ES
Danfoss 80°ES
Danfoss
80°ES
Danfoss
80°ES
Danfoss
80°H
size 0.45
0.55
0.60
0.55
0.65
0.75
0.75
0.85
0.85
0.85
1.10
1.25
Oil Pump
Pressure
bar
psi
6.8
99
8.0
116
8.0
116
10.0
145
8.7
126
10.0
145
9.0
131
8.0
116
10.0
145
10.0
145
9.0
131
9.0
131
% CO
2
Recommended
Maximum
11.5
12.5
11.5
12.5
11.5
12.5
11.5
12.5
11.5
12.5
11.5
12.5
11.5
12.5
11.5
12.5
11.5
12.5
11.5
12.5
11.5
12.5
11.5
12.5
Approx Fuel
Flow Rate
litres/h
Gals/h
1.65
0.36
1.98
0.44
2.35
0.52
2.35
0.52
2.65
0.58
2.98
0.65
2.98
0.65
3.40
0.75
3.81
0.84
3.81
0.84
4.48
0.99
5.25
1.16
Combustion Head
Position
mm 11.0
11.5
12.5
12.5
14.5
15.0
15.5
18.0
18.0
19.0
19.0
22.5
Flow Connection
28mm Compression
28mm Compression
28mm Compression
28mm Copper
Return Connection
22mm Copper
22mm Copper
28mm Compression
1¼” BSP Female
Water
Content
litres
gals
24
5.3
24
5.3
24
5.3
45
9.9
Boiler Weight Wet
kg
127
127
127
242
Factory Settings
Highlighted in bold
Summary of Contents for Agentis Series
Page 2: ......
Page 30: ...Page 29 4 5 Components 4 5 1 B Series Boilerhouse Casing Key Components...
Page 31: ...Page 30 4 5 2 I Series Internal Casing 21 26 33 Models 44 Models...
Page 32: ...Page 31 4 5 3 I Series Internal Key Components 21 26 33 Models 44 Models...
Page 33: ...Page 32 4 5 4 I Series Internal Pump Group 21 26 33 Models 44 Models...
Page 35: ...Page 34 4 5 7 E Series External Casing 21 26 33 Models 44 Models...
Page 36: ...Page 35 4 5 8 E Series External Key Components 21 26 33 Models 44 Models...
Page 37: ...Page 36 4 5 9 E Series External Pump Group 21 26 33 Models 44 Models...
Page 39: ...Page 38 4 5 12 Combination Boiler Pipe Layout...
Page 41: ...Page 40 5 1 2 I Series Internal I21 I26 I33 5 1 3 I Series Internal I44...
Page 43: ...Page 42 5 1 6 E Series External Base Tray E21 E26 E33 5 1 7 E Series External E44...
Page 45: ...Page 44 5 1 10 E Series External Combination Boiler Base Tray E21C E26C E33C...
Page 61: ...Page 60 6 3 3 External 230V Two Channel Programmer Room Thermostat Optional Outdoor sensor...
Page 62: ...Page 61 6 3 4 Internal Two Channel Programmer and Room Thermostat Optional Outdoor Sensor...
Page 73: ...Page 72 6 6 9 Honeywell Y Plan Independent CH DHW Fully Pumped Only 2 CHANNEL TIMECLOCK...
Page 74: ...Page 73 6 6 10 Honeywell S Plan Independent CH DHW Fully Pumped Only 2 CHANNEL TIMECLOCK...
Page 93: ...Page 92 Kabin Pak External Plume Management Kit KPMK The kit comprises...
Page 107: ...Page 106 11 4 Burner Start Up Cycle Lock out is indicated by a lamp on the control box...
Page 122: ...Page 121 14 SPARES 14 1 RDB 2 2 BX Spares...
Page 124: ...Page 123 14 2 RDB 3 2 BX Spares...
Page 134: ...Page 133 Intentionally left blank...
Page 135: ......