3.6
Timers for Standard Combi
Note
: Single channel timers or programmers are not recommended.
3.6.1 Installation of a remote two channel programmer (option 1)
Remove the purple wire connecting 5
and 28 and the white wire connecting 3
and 19.
Connect the programmer as shown via
a fused isolator.
This bypasses the central heating and
hot water on/off switch.
If the connection to terminal 12 is not
made the mains on lamp is also
bypassed.
A separate live supply to the boiler is
not required. However a neutral and
earth must be supplied to the boiler.
3.6.2 Installation of a remote two channel programmer (option 2)
Remove the purple, white and brown wires
connecting the central heating and hot water
on/off switches to the 6 pin male plug.
Connect the programmer as shown.
The mains is supplied via a fused isolator
to the boiler 3 pin mains plug.
OFF
OFF
E
N
L
COM
ON
22
21
20
19
PCB CONTROLLER
ON
COM
CH
HW
26
25
24
23
28
27
12
11
EARTH
POST
OFF
OFF
E
N
L
COM
ON
ON
COM
CH
HW
1
2
3
4
5
6
EARTH
POST
Page 20