INSTALLATION INSTRUCTIONS
TR05A140.B1107
28
4.8.4 Vertical coaxial balanced flue – Ø 60/100 (Kit V)
Figure 22: Ø 60/100 Vertical Kit V
Figure 23: Ø 60/100 Vertical Kit V dimensions
FOR CONDENSING BOILERS ONLY
Ø 60/100
MAXIMUM FLUE LENGTH = 5 m *
The flue length is the total length of the flue
excluding the first bend
.
The total length is calculated by summing
the lengths of all the straight section AND
the equivalent lengths of each bend (see
below).
Ø 80/125 x 90° bend = 0.8 m
Ø 80/125 x 45° bend = 0.5 m
* If a flue length of above 5 metres is
required, use the Ø 80/125 system.
Ø100
Ø60
163
131
Ø60
Ø100
m
a
x
.
5
.0
0
m
t.