14
Information screen 3 displays a list of values relating to the software used in the appliance as
shown in Figure 15. The most important of these values is the Software Ver. (meaning software
version). The example in Figure 15 displays the Software Ver. as 4.2.3a. It is beneficial to be
aware of the software version used on the appliance prior to seeking technical support.
Information screen 3 also displays the serial number of the appliance. The serial number cannot
be altered in the information screen shown in Figure 15. Instead, the serial number is configured
in the Engineer/Parameters sub-menu (See Commissioning Step 4 on Page 58). The serial
number displayed in the information screen should always match the serial number marked on
the label on the inside of the front casing door of the appliance.
The operating mode of the appliance varies through start-up, modulation and shut down, and
can be seen changing when viewing information screen 1 (see Figure 13). Further explanation
of each operating mode is given in Table 4.
Mode
Description
Standby
Awaiting heat demand
System Check Ensuring that the appliance is ready and safe to start – Duration 30 seconds
Pre-Load
Loading the combustion pot with pellets – Duration 2 minutes
Ignition
Igniting the pellets in the combustion pot – Variable duration – usually complete within 1 minute
Stabilisation
Ensuring that the flame is given time to establish – Duration 4 minutes
Powerband
1,2,3,4,5
Output power determined by heat demand – Variable duration
Extinguish
Shut down initiated – Variable duration – usually complete within 2 minutes
Final Clean
Cleaning of combustion pot and heat exchanger – Duration 30 seconds
Blocked
Anti-cycling function that activates a time delay before a restart is possible or the combustion door
can be opened – Duration 2 minutes
Table 4: Appliance Operating Modes.
Figure 15: Information Screen (3 of 3).