3.2.9. Operation in Summer Mode (if a boiler is fitted);
The boiler operates only for domestic hot water in this mode. To switch to
domestic water position;
3.2.10. Use with Room Thermostat (Optional)
The boiler is readily suitable for connection of ambient thermostats with
remote control sold as optional set. All Warmhaus thermostats can be
connected with dual-wired cable. Read the
operation and installation instructions in the accessories set. You can
control your boiler from anywhere (e.g. Your living room) thanks
to the control units with room thermostats and program clock,
and even use it in different modes and temperatures on different
days of the week.
Important:
If any thermostat is on/off used with remote control, it must
have two separate lines in accordance with the legislation in force. It is not
permitted to use any pipe or hose of the boiler as electrical or telephone
earthing line. Check this before making electrical connections of the boiler.
General Instructions of Use
• Consult our authorized services for room thermostats compatible with
Warmhaus boilers.
• Do not disassemble any parts while the appliance is operating.
• Do not place the appliance in areas exposed to direct sunlight or near any
hear sources.
• The manufacturer may not be held responsible for:
a) Incorrect installation
b) Intervention on the appliance by unauthorized person(s)
c) Noncompliance with the instructions given in this manual and manuals of
the room thermostat.
3.2.11. Use of Outside Temperature Sensor (Optional)
Installation Section; Accessories Connection Diagram) upon your request
allows automatic setting of the heating system temperature by instantly
responding to changes in outside temperature with Smart and comfortable
operation. Thus, it allows an efficient operation and saving energy by
reducing the heating system water temperature as the outside temperature
increases, and increasing the heating system water temperature as outside
temperature decreases which provides much more comfort without need
to manual setting. This sensor is activated when connected as independent
from presence or type of room thermostat, and the correlation between the
supply temperature of the system and outside temperature is determined
depending on the position of the button on the control panel, and
according to the curves given below.
After connecting the Outside Temperature Sensor, by means of the P04
parameter
It is adjusted according to average outside temperature of your province.
This setting will be performed by the Authorized Service during installation.
To turn off the boiler while operating in SUMMER mode;
Push
MODE
button, when background
light is on
the boiler will first switch to
SUMMER
mode
Then repeat the same steps, after cycle is
completed
will appear on the display
and background light will turn off, your
boiler is now in
STAND-BY
mode
Maintenance and Service Life:
Maintenance and service life: The Warmhaus
room thermostat should not come into contact with water or excessive
moisture. Your room thermostat does not require any maintenance unless
there is damage from outside. The service life is 5 years.
3.2.12. Customization of Boiler Functions
As the boiler has an advanced electronic card, certain parameters related
to operating conditions and your preferences can be set by our Authorized
Service. Please consult our Authorized Service when you desire to change
the parameters given below.
(P06) Heating System (Heating) Power.
The boiler is fitted with an electronic modulation with a capacity suitable
for actual heat requirement of the installation place. Thus, the boiler
automatically operates between minimum power and maximum power with
varying gas flow rates depending on the heat demand of the system.
(P07) Controlled Power Increase Duration.
When the boiler starts operating, it uses a controlled duration for reaching
preset maximum heating power. This time is set as 3 minutes as default, and
it can be extended up to 10 minutes.
(P21) Selection of low temperature zone.
This parameter shall be set as 1 for underfloor heating or other heating
systems operating at low temperature. The 0 (zero) value shall be selected
for systems operating at high temperature (radiator systems.
(P24) Child Protection
This parameter is not enabled as default, apply to our Authorized Service
to enable the parameter (protection lock is activated when Parameter is
set as 1). When the function is enabled keys will be locked approximately
2 minutes after use of the keys. Push MODE button until the cycle is
completed to unlock the keys and exit child protection mode. Your
appliance will be protected against any unintended changes in setting by
activating this function.
Figure 50
Outside Temperature Sensor
Figure 51
Outside Temperature Sensor Curves
CH Flo
w T
empar
atur
e °C
Outside Temperature °C
30
warmhaus.com