Error
Code
Description of the Error
Malfunction
Probable Cause
Solution(s)
E 94
Possible low gas pressure or
exhaust recirculation
Boiler does not work, E94 error
code flashing on the screen
> Gas inlet pressure LOW
> Recirculation of exhaust gas
into fresh air
> Blockage in flue or wrong
flue
> Aging or rust on the
electrode
> Electrode position
> Combustion calibration
> Gas valve failure
> Electronic board
1) Call for authorised service
E 95
Intermittent combustion value
Boiler does not work, E95 error
code flashing on the screen
> Harness on electrode and
earth
> Aging or rust on the
electrode
> Electrode position
> Combustion calibration
1) Call for authorised service
E 96
Flue or air suction way
blockage
Boiler does not work, E96 error
code flashing on the screen
> Blockage in flue
> Blockage in air suction path
1) Call for authorised service
E 98
SW error, board start-up error
fault
Boiler does not work, E98 error
code flashing on the screen
> Boiler software problem
1) Call for authorised service
E 99
Generic fault
Boiler does not work, E99 error
code flashing on the screen
> Boiler electronic hardware
problem
1) Reset & Restart boiler
2) Call for authorised service
(1) Call the Authorised Service if failure continues.
(2) 81 numbered failure corresponds any blocking in the exhaust gas pipe. In such case, you should consult the authorised service technician before re-starting the
boiler.
2.5.1. Filling/Emptying Radiator Installation
Ensure that the pressure reaches to 1-1,5 bar in the Manometer indicated
with
G symbol
by rotating the Fill Tap counter clockwise that is indicated
with
F symbol
in Lower View Figure 8 for filling the closed circuit radiator
installation after installation of the and close the Filling Tap by rotating
clockwise and discharge air of radiators via air discharge valves. Combi
boiler safety valve discharge should be connected to a discharge funnel.
Otherwise, safety valve shall be activated and manufacturer shall not be
responsible due to water discharge to the place of device.
0
3
2
1
0
3
2
1
1,5 bar
Figure 7
Filling the boiler
Figure 8
Boiler connections
0099_00.W200410
0096_00.W210806
A. Central Heating Flow (CH-3/4" thread)
B. Domestic Hot Water Outlet (DHW-1/2" thread)
C. Gas Inlet
D. Domestic Hot Water Inlet (DHW-1/2" thread)
E. Central Heating Return (CH-3/4" thread)
F. Filling Valve
G. Manometer
H. Pressure Relief Valve Outlet
I. Drain Point
J. Condansate Drain (Ø24 mm)
K. Power Supply (230V AC 50 Hz)