1. INTRODUCTION 

Warmhaus was established in 1996 and is an affiliate of Beycelik Holding 

which produces panel radiators, high capacity wall hung condensing 

boilers and steel panel radiators. Beycelik Holding has also branches 

in automotive, energy, tourism and insurance and currently provides 

employment opportunities for almost 5.000 people.

We thank you for chosing the Warmhaus boiler to maintain your heating 

and domestic hot water comfort for long years. Warmhaus products are 

manufactured in accordance with EU standards and exported to many 

countries. 

1.1. GENERAL WARNINGS

This book should be carefully protected and referred to when necessary, 

as it contains important information regarding operation of the product.
Please read these instructions fully before operating the appliance:

Radiator and DHW (Domestic Hot Water ) installations should be 

performed by a competent and certified engineering company in 

accordance with legal regulations in force.

This appliance must only be installed by a competent Gas Safe 

registered engineer and if in Ireland an RGI (Registered Gas 

Installer) and failure to adhere to this could lead to prosecution. 

In order to enable use of the boiler with LPG bottles or LPG tanks, 

conversation of the boiler should be performed by our authorised 

Warmhaus service. Project design and application for LPG use 

should be performed by the company supplying the tank in 

accordance with local and legal rules. 

1.2. GENERAL WARRANTY CONDITIONS

Manufacturer company cannot be held responsible for injury 

of people, other living things (animals, plants) or damage to 

properties due to installation by unauthorised people.

The maintenance and repairs as the result of failure of the product within 

the warranty period due to material, production and installation errors shall 

be performed as free of charge without claiming any workmanship costs 

and spare part payments.

The intended use for this appliance is to heat
water and supply DHW in domestic premises.

Always refer to the appliance data badge for correct specifications and 

ensure the boiler is operating within the safety settings outlined by 

Warmhaus.
The installation of the appliance and controls must be done in accordance 

to the current Gas Safety (Installation and Use) Regulations

Any intervention on a sealed component is forbidden.  

 

      

  

Maintenance and repairment of the appliance must only be carried 

out by a competent Gas Safe registered engineer and if in Ireland 

an RGI (Registered Gas Installer)

Children must not operate the boiler. 

 

 

 

 

       

 

Boilers bear CE mark in accordance with below given directives:
- Gas Appliances Directive 2009/142/EC
- Boiler Efficiency Directive 92/42/EEC
- Low Voltage Directive 2014/35/EU
- Electromagnetic Compatibility Directive 2014/30/EU

Manufacturer:

 WARMHAUS Isıtma ve Soğutma Sistemleri Tic. A.Ş. Bursa 

Işıktepe OSB Mah. Park Cad. No:10 16140 Nilüfer-Bursa / Türkiye

WARMHAUS

Warmhaus Authorised Technical Service Centres maintain an assurance 

regarding quality and professionalism. WARMHAUS is not responsible 

for damages arising from repairs, part replacements and maintenances 

performed by third persons and companies and product remains out of the 

warranty scope under such conditions.

1015

WARMHAUS A.Ş. reserves the right to make all kinds of technical and 
commercial amendments without giving information and rejects all 
responsibilities depending on misspelling.

Summary of Contents for ENERWA PLUS 42/40

Page 1: ...CONDENSING COMBI BOILERS USER MANUAL ENERWA PLUS 42 40 ENERWA PLUS 45 43...

Page 2: ...ildren with limited mental and sensory capabilities or by persons who do not have enough experience and or knowledge unless they are supervised by a person who is responsible for their safety or they...

Page 3: ...tand by Positions 8 2 1 3 Operation in Winter Mode 8 2 1 4 Operation in Summer Mode 9 2 1 5 Shutting off the Boiler 9 2 2 Use with Room Thermostat Optional 10 2 3 Use of Outside Temperature Sensor Opt...

Page 4: ...damage to properties due to installation by unauthorised people The maintenance and repairs as the result of failure of the product within the warranty period due to material production and installat...

Page 5: ...mbar G25 DE II 2L3P Natural Gas 25 mbar G25 NL II 2L3B P Natural Gas 25 mbar G25 NL II 2ELL3B P Natural Gas 20 mbar G25 DE I 3 Buthane Gas 28 30 mbar 37 mbar G30 BE CH CY CZ ES FR GB GR IE IT LT PT SI...

Page 6: ...rn off the gas supply at the gas meter or an appropriate emergency control valve Immediately evacuate the place Call the National Gas Emergency Service Do not make any intervention on installation Nev...

Page 7: ...his booklet are strictly followed for safe and economical operation of the boiler Important Notes This appliance must not be operated without the casing correctly fitted and forming an adequate seal I...

Page 8: ...ent change will be activated when radiator symbol rapidly flashes DHW adjustment change will be activated when tap symbol rapidly flashes CH Central Heating DHW Domestic Hot Water When the boiler is s...

Page 9: ...en on the screen and LCD screen backlight is turned OFF In this mode you can adjust the Domestic Hot Water temperature between 35 60 C with 7 and 8 numbered buttons LCD screen backlight is turned ON d...

Page 10: ...ce installation shall only be performed by the Warmhaus Authorised Service The dual cable required for installation is supplied by the dealer consumer Maintenance and Service Life Warmhaus room thermo...

Page 11: ...or systems to operate at high temperatures as standard P24 Child Protection This feature is disabled as default factory setting 0 Child Protection key lock is enabled when parameter is adjusted to 1 K...

Page 12: ...er and check if problem is resolved 5 Call for authorised service E 08 Flame circuit failure False flame signal from combustion or electrode Condensate Syphon blocked Electronic board 1 Call for autho...

Page 13: ...munication error Boiler does not work E43 error code flashing on the screen after 1 minute of communication error Opentherm line disconnected 1 Remove energy from boiler and re energize E43 will be re...

Page 14: ...disconnections Gas valve failure 1 Call for authorised service E 88 Fault of electronic gas valve managing circuit Boiler does not work E88 error code flashing on the screen Cabling disconnections Gas...

Page 15: ...n the screen Boiler electronic hardware problem 1 Reset Restart boiler 2 Call for authorised service 1 Call the Authorised Service if failure continues 2 81 numbered failure corresponds any blocking i...

Page 16: ...h and also you can acquire approximately 6 power saving with every degree of temperature decrease Ventilation Do not leave windows slightly open for ventilating room rooms In such case continuous heat...

Page 17: ...nt test conditions Only the data that is contained in this product information is applicable and valid Electricity Fuel HANDING OVER After completing the installation and commissioning of the system t...

Page 18: ...Boilernation boiler Yes Yes B1 Boiler No No Room boiler with combi boilerned heat and power Yes Yes Auxiliary boiler No No Brand Name Warmhaus Manufacturer adress Warmhaus Is tma ve Sogutma Sistemler...

Page 19: ...19 warmhaus com...

Page 20: ...Enerwa Plus 42 45 User Manual INT Code 15011606000131 Revision Date 08 2021 CONDENSING COMBI BOILERS USER MANUAL ENERWA PLUS 42 40 ENERWA PLUS 45 43...

Reviews: