7
warmhaus.com
2. USER’S SECTION
2.1. GENERAL WARNINGS FOR USER
2.1.1. Use of boiler
Perform below given controls prior to use:
• Ensure that radiator/heating system, tap water and gas valves located in
your boiler are open, the heating system pressure is between 1 - 1,5 bar
and system air is discharged,
• Gas is available in your gas line (you can control by igniting one of your
gas ovens),
• Make sure there are no combustible materials within the immediate
vicinity of the appliance or any corrosive chemicals that can damage the
appliance.
• If a room thermostat or control device is connected, ensure that it is at
ON position.
Our boiler has a built in frost protection (as long as the appliance is ON
and gas provided) for the system water contained within the boiler only, so
provisions need to be installed to protect the system pipe work in unheated
areas.
Turn OFF the boiler before any maintenance and repair action.
Follow below given main rules:
• Do not clean external frame of boiler while is functioning and do not use
easily flammable materials.
• Do not touch electricity cables.
• In case cables are damaged, the boiler and fuse switches and do not use
the boiler.
• Electrical cables of boiler and its accessories should be replaced by the
Authorised Service.
Safety:
In your own interest, and that of safety, it is the law that this boiler must
be installed by in in accordance with the current Building Regulations and
reference should be made to the current rules for electrical installation.
It is essential that the instructions in this booklet are strictly followed, for
safe and economical operation of the boiler.
Important Notes:
• This appliance must not be operated without the casing correctly fitted
and forming an adequate seal.
• If the boiler is installed in a compartment then the compartment MUST
NOT be used for storage purposes.
• If it is known or suspected that a fault exists on the boiler then it MUST
NOT BE USED until the fault has been corrected by a Gas Safe Registered
Engineer.
• Under NO circumstances should any of the sealed components on this
appliance be used incorrectly or tampered with.
• This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instructions
concerning use of the appliance by a person responsible for their safety.
Figure 1
Control panel of Enerwa Plus Combi Boiler
Figure 2
Control Panel with Touch Screen of Enerwa Plus
1.
MODE
, selection button.
2.
RESET
button.
3. Radiator (CH) water
temperature increasing button.
4. Radiator (CH) temperature
decreasing button.
5. Service port.
6. Digital display screen.
7. Domestic Hot Water
temperature increasing button.
8. Domestic Hot Water
temperature decreasing button.
9. Flame modulation indicator
10. Radiator (CH) water
temperature.
11. Radiator (CH) mode operating
indicator.
12. Domestic Hot Water
temperature.
13. Domestic Hot Water operating
indicator.
14. Comfort mode operation.
15. Failure status RESET
requirement.
16. External Weather Temperature
Sensor connection indicator
17. Digital manometer
18. Failure indicator.
19. Room thermostat (OpenTherm-
OT) connection indicator
2
1
6
4
5
8
3
7
14
17
19
10
9
15
11
16
13
12
18
0005_00
.W17
05
19
0005_00
.W17
05
19