background image

7

warmhaus.com

2. USER’S SECTION

2.1. GENERAL WARNINGS FOR USER

2.1.1. Use of boiler

Perform below given controls prior to use:

•  Ensure that radiator/heating system, tap water and gas valves located in 

your boiler are open, the heating system pressure is between 1 - 1,5 bar 
and system air is discharged,

•  Gas is available in your gas line (you can control by igniting one of your 

gas ovens),

•  Make sure there are no combustible materials within the immediate 

vicinity of the appliance or any corrosive chemicals that can damage the 
appliance. 

•  If a room thermostat or control device is connected, ensure that it is at 

ON position.

Our boiler has a built in frost protection (as long as the appliance is ON 

and gas provided) for the system water contained within the boiler only, so 

provisions need to be installed to protect the system pipe work in unheated 

areas. 
Turn OFF the boiler before any maintenance and repair action.

Follow below given main rules:

•   Do not clean external frame of boiler while is functioning and do not use 

easily flammable materials. 

•   Do not touch electricity cables.
•   In case cables are damaged, the boiler and fuse switches and do not use 

the boiler.

•   Electrical cables of boiler and its accessories should be replaced by the 

Authorised Service.

Safety:

In your own interest, and that of safety, it is the law that this boiler must 

be installed by in in accordance with the current   Building Regulations and 

reference should be made to the current rules for electrical installation.
It is essential that the instructions in this booklet are strictly followed, for 

safe and economical operation of the boiler. 

Important Notes:

•  This appliance must not be operated without the casing correctly fitted 

and forming an adequate seal.

•  If the boiler is installed in a compartment then the compartment MUST 

NOT be used for storage purposes.

•  If it is known or suspected that a fault exists on the boiler then it MUST 

NOT BE USED until the fault has been corrected by a Gas Safe Registered 
Engineer.

•  Under NO circumstances should any of the sealed components on this 

appliance be used incorrectly or tampered with.

•  This appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience 
and knowledge, unless they have been given supervision or instructions 
concerning use of the appliance by a person responsible for their safety.

Figure 1 

Control panel of Enerwa Plus Combi Boiler

Figure 2 

Control Panel with Touch Screen of Enerwa Plus

1. 

MODE

, selection button.

2. 

RESET

 button.

3.  Radiator (CH) water 

temperature increasing button.

4.  Radiator (CH) temperature 

decreasing button.

5.  Service port.
6.  Digital display screen.
7.  Domestic Hot Water 

temperature increasing button.

8.  Domestic Hot Water 

temperature decreasing button.

9.  Flame modulation indicator
10. Radiator (CH) water 

temperature.

11.  Radiator (CH) mode operating 

indicator.

12.  Domestic Hot Water 

temperature.

13.  Domestic Hot Water operating 

indicator.

14. Comfort mode operation.
15.  Failure status RESET 

requirement.

16.  External Weather Temperature 

Sensor connection indicator

17.  Digital manometer
18.  Failure indicator.
19.  Room thermostat (OpenTherm-

OT) connection indicator

2

1

6

4

5

8

3

7

14

17

19

10

9

15

11

16

13

12

18

0005_00

.W17

05

19

0005_00

.W17

05

19

Summary of Contents for ENERWA PLUS 42/40

Page 1: ...CONDENSING COMBI BOILERS USER MANUAL ENERWA PLUS 42 40 ENERWA PLUS 45 43...

Page 2: ...ildren with limited mental and sensory capabilities or by persons who do not have enough experience and or knowledge unless they are supervised by a person who is responsible for their safety or they...

Page 3: ...tand by Positions 8 2 1 3 Operation in Winter Mode 8 2 1 4 Operation in Summer Mode 9 2 1 5 Shutting off the Boiler 9 2 2 Use with Room Thermostat Optional 10 2 3 Use of Outside Temperature Sensor Opt...

Page 4: ...damage to properties due to installation by unauthorised people The maintenance and repairs as the result of failure of the product within the warranty period due to material production and installat...

Page 5: ...mbar G25 DE II 2L3P Natural Gas 25 mbar G25 NL II 2L3B P Natural Gas 25 mbar G25 NL II 2ELL3B P Natural Gas 20 mbar G25 DE I 3 Buthane Gas 28 30 mbar 37 mbar G30 BE CH CY CZ ES FR GB GR IE IT LT PT SI...

Page 6: ...rn off the gas supply at the gas meter or an appropriate emergency control valve Immediately evacuate the place Call the National Gas Emergency Service Do not make any intervention on installation Nev...

Page 7: ...his booklet are strictly followed for safe and economical operation of the boiler Important Notes This appliance must not be operated without the casing correctly fitted and forming an adequate seal I...

Page 8: ...ent change will be activated when radiator symbol rapidly flashes DHW adjustment change will be activated when tap symbol rapidly flashes CH Central Heating DHW Domestic Hot Water When the boiler is s...

Page 9: ...en on the screen and LCD screen backlight is turned OFF In this mode you can adjust the Domestic Hot Water temperature between 35 60 C with 7 and 8 numbered buttons LCD screen backlight is turned ON d...

Page 10: ...ce installation shall only be performed by the Warmhaus Authorised Service The dual cable required for installation is supplied by the dealer consumer Maintenance and Service Life Warmhaus room thermo...

Page 11: ...or systems to operate at high temperatures as standard P24 Child Protection This feature is disabled as default factory setting 0 Child Protection key lock is enabled when parameter is adjusted to 1 K...

Page 12: ...er and check if problem is resolved 5 Call for authorised service E 08 Flame circuit failure False flame signal from combustion or electrode Condensate Syphon blocked Electronic board 1 Call for autho...

Page 13: ...munication error Boiler does not work E43 error code flashing on the screen after 1 minute of communication error Opentherm line disconnected 1 Remove energy from boiler and re energize E43 will be re...

Page 14: ...disconnections Gas valve failure 1 Call for authorised service E 88 Fault of electronic gas valve managing circuit Boiler does not work E88 error code flashing on the screen Cabling disconnections Gas...

Page 15: ...n the screen Boiler electronic hardware problem 1 Reset Restart boiler 2 Call for authorised service 1 Call the Authorised Service if failure continues 2 81 numbered failure corresponds any blocking i...

Page 16: ...h and also you can acquire approximately 6 power saving with every degree of temperature decrease Ventilation Do not leave windows slightly open for ventilating room rooms In such case continuous heat...

Page 17: ...nt test conditions Only the data that is contained in this product information is applicable and valid Electricity Fuel HANDING OVER After completing the installation and commissioning of the system t...

Page 18: ...Boilernation boiler Yes Yes B1 Boiler No No Room boiler with combi boilerned heat and power Yes Yes Auxiliary boiler No No Brand Name Warmhaus Manufacturer adress Warmhaus Is tma ve Sogutma Sistemler...

Page 19: ...19 warmhaus com...

Page 20: ...Enerwa Plus 42 45 User Manual INT Code 15011606000131 Revision Date 08 2021 CONDENSING COMBI BOILERS USER MANUAL ENERWA PLUS 42 40 ENERWA PLUS 45 43...

Reviews: