11
warmhaus.co.uk
2.3. Location of Boiler / Clearance
CAUTION
The boiler must be installed on a flat fixed surface which is suitable to
support the weight of the boiler and any ancillaries that maybe required
for the Installation.
Service and maintenance should also be considered when choosing the
location of the boiler unit.
The boiler must not be installed outside
Please follow the below installation points.
•
Frost protection:
Our boiler has a built in frost protection for the system
water contained within the boiler only, so provisions need to be installed
to protect the system pipe work in unheated areas.
•
Accessible:
The boiler must be installed in a well lit location that is
suitable for engineers to carry out maintenance on the appliance and for
the customer to safely adjust any controls on the boiler. All roof space
installations should comply to BS5410 part 1 – roof space installations.
•
Storage:
Do not store any flammable materials around the location of
the boiler or chemicals of any kind.
Installations in rooms containing baths or showers
Warmhaus Ewa Combi Boiler has an IPX5D rating
Any switch or appliance external controls using mains electricity should not
be in reach of any person using a bath or shower.
All installations must be in accordance with all the current regulations and
latest amendments of the IET wiring regulations
(BS7671) or in Ireland
Irish Standard IS 10101:2020
Boiler Height : 725 mm
Boiler Width: 420 mm
Boiler Depth : 288 mm
Flue Centre: 208 mm (from left side of boiler to flue center)
min.
30
mm
min.
30
mm
550 mm
422 mm
min. 100 mm
min. 50 mm
727 mm
169 mm
286 mm
Clearances:
Above : 219 mm
Below : 300 mm
Left
: 30 mm
Right : 30 mm
288
30
118
725
725
208
208
118
420
A
B
C
D
E
0
0
26_0
0.
W21
0
116
0027_00.W210419