29
warmhaus.co.uk
3.16.1. External Control Connection / Low Voltage Installation
CAUTION
THE GREEN CONNECTIONS ON OUR TERMINAL CONNECTOR ARE LOW
VOLTAGE AND 240V MUST NOT BE CONNECTED TO THESE.
If your external controls have a 240 V output then please use our 240 V
relay connector.
To connect your low voltage external control, remove the green link wire
and connect your two external control cables to the two green wires on the
terminal connector.
3.16.2. External Control Connection / High Voltage (240 V) Installation
CAUTION
To connect your 240 V external control, remove the green link wire on the
boiler terminal connector and connect your two external control cables
onto the power relay LIVE and NEUTRAL connectors supplied with the
power relay.
Then connect the two LOW VOLTAGE cables connected to the power relay
to the green wires on the terminal connector.
0075_00.WUK200821
0074_00.W200825
0076_00.WUK200821
(TO PCB MAIN SUPPLY)
Brown
Blue
Yellow/Green
MAIN SUPPLY
230V AC
Room
Thermostat
Oran
ge
Whi
te
Green
3A
Fu
se
THERMINAL BLOCK