3.16.4. External Control Connection / YPlan Wiring Diagram
RISK OF ELECTRIC SHOCK
BOILER WITHOUT TIMER MODEL
YPLAN Wiring Guide:
The Warmhaus Ewa boiler must have clean contact connections and must
not have voltage connected to the room stat position on our terminal
connector, therefore if the system configuration is a YPLAN you must
connect the relay supplied with our boiler as per the above image to
provide a switching method of taking mains 240v switched live supply
from the zone valve and supplying the room stat connection from the relay
output as clean contacts voltage free.
0078_00.WUK200821