3.2.13. Customizing Combi Features

As your combi has an advanced electronic card, operation conditions and 
certain parameters related with your preferences may be changed by 
our Authorized Service. Please consult our authorized service when any 
changes requested in below given parameters.

(P06) (CH) (Heating) Power.

Combi is equipped with an electronic modulation with power suitable with 
actual heat requirement of installation place. Thus, the combi automatically 
operates with variable gas flow rates depending on heat load of installation 
between the minimum and maximum power.

(P07) Controlled Power Increase Period.

When combi starts, it uses a controlled period defined for reaching the 
adjusted maximum heating power. This period is adjusted as 3 minutes as 
standard and can be increased up to 3 minutes.

(P21) Low temperature region selection.

This parameter should be adjusted as 1 for ground heating or heating 
systems operating with low temperature. 0 (zero) value is selected for 
radiator systems to operate at high temperatures as standard.

(P24) Child Protection

Your combi is protected against setting changes with the child lock that is 
activated when the MODE button is pressed for 5 seconds.
Protection lock is activated when the parameter is adjusted as 1.

(P40) Radiator ignition delay period.

Combi device is equipped with an electronic timer for preventing frequent 
ignition by the combi during heating stage. This period is adjusted as 2 
minutes as standard and can be increased up to 10 minutes.

(P42) Ready Hot Water (Pre-Heating passive/active).

In order to rapidly prepare the domestic hot water without your request and 
reducing the cold water consumption during waiting, it heats the grid water 
in plate exchanger and keeps as hot water.  This function can be activated 
in 6 buttons LAWAPLUS models.  Pre-heating function is activated when 
domestic hot water temperature increase Figure 28 (2) RESET button is 
pressed until cycle is completed. At the end of this period, Pre-On (active), 
Pre-Off (passive) is seen on the LCD screen for 5 seconds.

Activation of this function in LAWA models is enabled with parametric 
adjustment by our Authorized Service according to your request.
 

Air Discharge Function

Activating the menu for LAWA, PRIWA and ENERWA models:
Air discharge function can be activated by pressing the RESET button more 
than 5 seconds while CH button and DHW button are at maximum position. 
Upon activation of this function, 3 way valve and pump is operated or not 
operated for discharging the air within the radiator installation.

4. TROUBLESHOOTING

4.1.  FAILURE CODES TABLE

 

Failure 

Code

Description of the Error

Malfunction

Probable Cause

Solution(s)

E 01

Intervention of exhaust Ther-
mostat (Open Combustion 
Chamber boiler )

Boiler does not work, E01 
error code flashing on the 
screen

> Flue Sensor faulty

1-) Reset & Restart boiler
2-) Call for authorised service at first

E 02

Low water pressure in the 
system/system parameter 
wrongly setted

Boiler does not work, E02 
error code flashing on the 
screen

> Water pressure in the boiler 
not enough

1-) Fill the boiler 1,2-1,5 bar according to manual page 28 or 29 problem 
will automatically removed 
2-) Check if the system pressure 1,2 - 1,5 bar from the manometer 
located right & bottom of the boiler 
3-) If problem persist Call for authorised service 
4-) Reset & Restart boiler

E 03

High water pressure in the 
system

Boiler does not work, E03 
error code flashing on the 
screen

> High Water pressure  
in the boiler higher  
than > 2,8 bar

1-) Drain the boiler water until 1,2-1,5 bar according to manual page 28 
or 29 problem will automatically removed 
2-) Check if the system pressure 1,2 - 1,5 bar from the manometer 
located right & bottom of the boiler 
3-) If problem persist Call for authorised service 
4-) Reset & Restart boiler

E 04

Domestic heating water 
temperature sensor faulty

Boiler does not work on DHW 
mode but still work on Cen-
tral heating mode, E04 error 
code flashing on the screen

> Domestic heating water 
temperature sensor faulty

1-) Call for authorised service at first
2-) Check intermittent contacts or open contacts on harness carefully
3-) Check Domestic heating water temperature sensor ressistance 
according to page 95 at section 4.30 if its out of tolerance replace NTC
4-) Check cabeling and connectors between double NTC and board
5-) Reset & Restart boiler

E 05

Central heating FLOW tem-
perature sensor faulty

Boiler does not work, E05 
error code flashing on the 
screen

> Central heating FLOW 
temperature sensor faulty

1-) Call for authorised service at first

Summary of Contents for LAWA 18

Page 1: ...CONVENTIONAL COMBI BOILERS INSTALLATION USER MANUAL LAWA LAWA PLUS...

Page 2: ...Lawa LawaPlus Enerwa E24 EnerwaPLUSE24...

Page 3: ...2 2 16 Installation at Partially Protected Exteriors 12 2 2 17 Electrical Connections 12 2 2 18 Optional Controls Room Thermostat External Weather Temperature Sensor and Others 13 2 3 HYDRAULIC INSTA...

Page 4: ...under any circumstances during installation use or maintenance operations and device warranty shall also be void Only the authorized Warmhaus Service is authorized to make the electrical connection o...

Page 5: ...r matches Close valves of devices operating with natural gas and your gas meter Immediately evacuate the place with gas odour Natural Gas Emergency Line from your neighbour or another suitable place D...

Page 6: ...lace Wall installation for the combi boiler should be well secured The hanger plate given as standard with the combi should be installed according to the technique to a full or semi full brick wall ac...

Page 7: ...abnormal operations Various alloy layers may be formed during transit of LPG gas in tanks depending on mixture compositions That causes a change in heating power of mixture assigned to the device and...

Page 8: ...er and by using elbows as low as possible At least 1 bar pressurized grid input water should be supplied to ensure adequate domestic hot water Hydrophore should be used if required Figure 10 Flue peri...

Page 9: ...plications Each 45 elbow usage requires to decrease maximum 50 cm from horizontal vertical distance 60 100 Conventional 90 Elbow 153 11 660 600009 It can be used in horizontal and or vertical flue app...

Page 10: ...elbow contacting with the restrictive set Place the External Wall Plate into the flue terminal as seen in Figure 11 12 for grouping the flue output terminal After placing the flue output terminal thr...

Page 11: ...rd Flue Set Elbow 90 b Flue Extension Pipe c Additional 90 Elbow d Standard Flue Set Pipe Figure 16 II Two 90 elbow sample flue installations d a b c a b c d 4 m Figure 15 I Single 90 bended sample fl...

Page 12: ...Hermetic Flue Type fire resistant insulation material is placed between the wall and exhaust gas relief pipe Materials used for manufacturing the combi are resistant against glycol and propylene based...

Page 13: ...sockets and extension cables are not allowed to use 2 2 17 Optional Controls Room Thermostat External Weather Temperature Sensor and Others Room thermostat Outside Temperature Sensor etc control devi...

Page 14: ...of the radiator Combi safety valve relief should be connected to a discharge cone Otherwise safety valve shall be activated and manufacturer shall not be responsible due to water discharge around the...

Page 15: ...s valve radiator and tap water valves If you will shut off the combi for a short period perform below written operations Do not close combi electrical fuse gas valve radiator and tap water valves Leav...

Page 16: ...screens consist of navy blue colored backlight LCD screen 2 buttons Radiator 3 and Hot Tap Water 4 and 2 pcs RESET 2 and MODE 1 pushbuttons RESET It is used for re starting the combi and eliminating t...

Page 17: ...en light turns off At that position you can adjust the temperature between 35 80 C with the Radiator CH temperature adjustment button 3 Temperature value increases when button is rotated clockwise or...

Page 18: ...if the pressure is lower than this value 18 Failure indicator The temperature value displayed on the combi screen has a 3 C tolerance depending on environmental conditions not arising from the combi...

Page 19: ...installation Hold the MODE button for switching on the combi when letter is available on the screen A cycle starts on the screen Release the button when cycle is completed In some cases combi initiall...

Page 20: ...er is seen as the screen screen light turns off your combi is now at STANDBY position Figure 31 Thermostat position Figure 32 Outside weather temperature sensor Figure 33 Outside temperature sensor op...

Page 21: ...zed Service according to your request Air Discharge Function Activating the menu for LAWA PRIWA and ENERWA models Air discharge function can be activated by pressing the RESET button more than 5 secon...

Page 22: ...ermittent contacts or open contacts on harness carefully 3 Check Domestic heating water temperature sensor ressistance 4 Check cabeling and connectors between NTC and board 5 Reset Restart boiler E 13...

Page 23: ...vice at first E 42 Buttons anomaly Boiler does not work E42 error code flashing on the screen Wrong parameters settled on TsP menu 1 Call For service E 43 Opentherm communication error Boiler does not...

Page 24: ...st perform Au To calibration E 78 Max regulation current value reached Boiler does not work E78 error code flashing on the screen Gas inlet pressure Aging or rust on the electrode Recirculation on flu...

Page 25: ...Au To calibration E 88 Fault of electronic gas valve managing circuit Boiler does not work E88 error code flashing on the screen Cabeling disconnections Gas valve failiure 1 Call for authorised servi...

Page 26: ...ration Temporary wind precence 1 If there is strong wind ie wind storm wait until the wind storm stop then keep using the boiler as it is 36 or 48 hours boiler try to remove half power mode by it self...

Page 27: ...ailures occurring due to transportation unloading loading storing external physical Crushing scratches fractures and chemical factors following delivery of the product 6 Damages and failures arising f...

Page 28: ...10 7 28 10 32 5 12 8 Max Domestic Hot Water flow rate t 30 C min 10 5 10 9 10 7 10 9 13 9 13 3 13 9 14 2 Maximum Minimum water pressure bar 10 0 3 10 0 3 10 0 3 10 0 3 Temperature adjustment range oC...

Page 29: ...2ELL I 2H I3P NUMBER OF CHOOSED CONNECTING CONDITIONS Used gas G20 G20 G25 G25 G20 G25 G20 G31 Countries of destination AT BG CH CZ DK EE ES FI GB GR IE IT LT LV NO PT RO SE SI SK DE LU PL RO BE FR NL...

Page 30: ...30 warmhaus com...

Page 31: ...been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject...

Page 32: ...CONVENTIONAL COMBI BOILERS INSTALLATION USER MANUAL LAWA LAWA PLUS Instruction booklet code of Lawa LawaPlus 150 11 606 000004 Revision Date 09 2020...

Reviews: