10
warmhaus.com
1.
MODE
, selection button.
2.
RESET
button.
3. Radiator (CH) water temperature increasing button.
4. Radiator (CH) temperature decreasing button.
5. Digital display screen
6. Domestic Hot Water temperature increasing button.
7. Domestic Hot Water temperature decreasing button.
8. Boiler actual power indicator
9. Radiator (CH) water actual temperature
10. Radiator (CH) mode operating indicator
11. Domestic Hot Water actual temperature
12. Domestic Hot Water operating indicator
13. Comfort mode operation
14. Failure status
RESET
requirement.
15. External Weather Temperature Sensor connection
16. Digital manometer
17. Failure code.
18.
Room thermostat (OpenTherm-OT) connection
indicator
The temperature value displayed on the digital screen has
a ± 3 °C tolerance depending on environmental conditions
not arising from the boiler. Screen of MinerWa 25 boiler
model consist of amber coloured backlight LCD screen
and 6 touch sensitive buttons : RESET, MODE, CH (+), CH
(-), DHW (+), DHW (-).
Figure 1
Control panel of MinerWa 25 Combi Boiler
Figure 2
Control Panel with Touch Screen of MinerWa
25 Boiler
2
5
7
4
3
6
1
13
16
18
9
8
14
10
15
12
11
17
RESET:
It is used for resetting the failure (if temporary)
re-starting the boiler
MODE:
Used for Winter/Summer/OFF mode adjustment.
Operating modes and related notifications:
OPERATING MODES EXPLANATIONS:
•
OFF
•
WINTER
►
Radiator tempe °C + tap + radiator
is displayed.
•
SUMMER
►
Radiator tempe °C + tap is
displayed.
•
CH ON
►
Radiator Tempe °C + tap + flashing
radiator (symbol) is displayed.
•
DHW ON
►
DHW tempe °C + flashing tap
(symbol) is displayed.
•
CH FROST PROTECTION
►
Radiator temperature
• °C + flashing radiator (symbol) + when boiler is ignited
flame (symbol) is displayed.
•
DHW FROST PROTECTION
►
CH tempe °C
flashing radiator and tap (symbol) + when boiler
ignited flame (symbol)
•
CH/DHW SETTING CHANGE
►
CH adjustment change
will be activated when radiator symbol rapidly flashes.
DHW adjustment change will be activated when tap
symbol rapidly flashes.
CH:
Central Heating
DHW:
Domestic Hot Water
2.1.2. Selection of On/Off/Stand-by and
Summer/Winter Modes
The boiler panel does not have
ON/OFF
button. The
boiler must be turned on/off by using the V circuit breaker
to be connected to the boiler circuit.
2.1.3. On/Off/Stand-by Positions
The boiler panel does not have
ON/OFF
button. The
boiler must be turned on/off by using the V circuit breaker
connected to the boiler circuit.