2.1.6. Shutting off the Boiler

To set the boiler to OFF position while it is in SUMMER 
position;

To set the boiler to 

OFF

 mode while it is in 

WINTER

;

Press and hold 

MODE

 button and 

release the button after cycle on 
the screen 

 is completed, 

 will be displayed on the 

screen, backlight is turned OFF, 
now the boiler is in OFF mode.

Press and hold 

MODE

 button and 

release the button after cycle on 
the screen 

 is completed, 

boiler will switch to 

SUMMER

 

mode.

Then, when the same 
transaction is repeated, after 
cycle is completed 

 will be 

displayed on backlight is turned 
OFF boiler is now at 

STANDBY

 

position.

2.2. USE WITH ROOM THERMOSTAT 

(OPTIONAL)

This product can be used together with a room 
thermostat which can be purchased separately as an 
accessory. All Warmhaus thermostats can be connected 
with dual-wired cables. Carefully read user’s and 
installation instructions given in the Accessory set. When 
connected to a room thermostat, the appliance can be 
operated based on requested room temperature. With 
certain models of control units, you may run your boiler 
on a daily / weekly programme. 

General Utilisation Type 

• Please consult our authorised services for room 

thermostats compatible with Warmhaus boilers.

•  Do not remove device components during operation.
•  Do not place the boiler in a position allowing direct 

sunlight exposure or near heat sources.

•  Manufacturer company shall not be responsible for 

below given situations:

  a) Faulty installation
  b) Making intervention on the device by unauthorised 

persons

  c) Failing to follow instructions given in this book and 

room thermostat booklets 

Room thermostat should be installed at 1,50 m 
height from ground.

At least 30 cm distance should be available 
from doors and windows open for air 
circulation.

Installation instruction:

 Device installation shall only be 

performed by the Warmhaus Authorised Service. The 
dual cable required for installation is supplied by the 
dealer/consumer.

Figure 3 

Thermostat position

150 cm

Min.

30 cm

Maintenance and Service Life:

 Warmhaus room 

thermostat should not come into contact with water or 
excessive humidity. Unless an external damage occurs, 
the room thermostat does not require any maintenance.

2.3. USE OF OUTSIDE TEMPERATURE 

SENSOR (OPTIONAL)

This product can be used together with a weather 
compensation kit which can be purchased separately as 
an accessory.
When connected to a weather compensation kit, the 
appliance runs with reference to the weater temperature, 
based on selected heating curve. Available heating curves 
are given in figure 5.

Summary of Contents for MINERWA 25 COMBI-IE

Page 1: ...MINERWA 25 31 COMBI IE MINERWA 25 SYSTEM IE CONDENSING BOILER USER MANUAL...

Page 2: ...2 warmhaus com MinerWa 25 31 Combi IE MinerWa 25 System IE...

Page 3: ...OFF STAND BY AND SUMMER WINTER MODES 10 2 1 3 ON OFF STAND BY POSITIONS 10 2 1 4 OPERATION IN WINTER MODE 11 2 1 5 OPERATION IN SUMMER MODE 11 2 1 6 SHUTTING OFF THE BOILER 12 2 2 USE WITH ROOM THERM...

Page 4: ...iler should be performed by our authorised Warmhaus service Project design and application for LPG use should be performed by the company supplying the tank in accordance with local and legal rules 1...

Page 5: ...on installation of gas fired heating devices www warmhaus com Manufacturer WARMHAUS Is tma ve So utma Sistemleri Tic A Bursa I ktepe OSB Mah Park Cad No 10 16140 Nil fer Bursa T rkiye WARMHAUS Warmha...

Page 6: ...G20 DE II 2ELL3B P Natural Gas 20 mbar G20 DE I 2L Natural Gas 25 mbar G25 NL I 2E Natural Gas 25 mbar G25 BE FR I 2ELL Natural Gas 20 mbar G25 DE II 2L3P Natural Gas 25 mbar G25 NL II 2L3B P Natural...

Page 7: ...0 mbar G30 AT CH SK II 2E3B P Buthane Gas 50 mbar G30 DE II 2L3B P Buthane Gas 30 mbar G30 NL II 2ELL3B P Buthane Gas 50 mbar G30 DE I 3P Propane LPG 37 mbar G31 BE CH CZ ES FR GB GR HR IE IT LT NL PL...

Page 8: ...ff the gas supply at the gas meter or an appropriate emergency control valve Immediately evacuate the place Call the National Gas Emergency Service 0800111999 or in Ireland 1850 20 50 50 Do not make a...

Page 9: ...es should be replaced by the Authorised Service Do not expose the boiler to direct vapour those may arise from cooking places Safety In your own interest and that of safety it is the law that this boi...

Page 10: ...3 16 18 9 8 14 10 15 12 11 17 RESET It is used for resetting the failure if temporary re starting the boiler MODE Used for Winter Summer OFF mode adjustment Operating modes and related notifications O...

Page 11: ...en light is turned off When boiler is started flame modulation symbol is seen at the middle section of the screen At that position you can increase and decrease the temperature with CH temperature adj...

Page 12: ...om thermostats compatible with Warmhaus boilers Do not remove device components during operation Do not place the boiler in a position allowing direct sunlight exposure or near heat sources Manufactur...

Page 13: ...sing RESET and for circle time Air will be displayed on the screen Boiler will start the Deareation function During this function pump and 3 way valve are activated deactivated in order to have deaera...

Page 14: ...omestic hot water temperature sensor faulty Boiler does not work in DHW mode but still operational in Central heating mode E04 error code flashing on the screen Domestic heating water temperature sens...

Page 15: ...FLUE temperature sensor faulty 1 Reset Restart boiler 2 Call for authorised service E 15 Fan failure feedback supply Boiler does not work E15 error code flashing on the screen Fan harness 1 Reset Res...

Page 16: ...provider 2 Error will remove if supply voltage 170 VAC 5 3 If this failure is observed during calibration calibration can not be complete unless supply voltage 188 VAC 5 E 40 Wrong network frequency...

Page 17: ...thorised service at first 2 Check RETURN and FLOW sensor on position E 74 Second CH temperature Probe faulty Boiler does not work E74 error code flashing on the screen FLOW and LIMIT Sensor double NTC...

Page 18: ...ng on the screen Strong flue blockage Combustion problem Wrong flue Gas inlet pressure Aging or rust on the electrode Recirculation of exhaust gas into fresh air Electrode position Combustion calibrat...

Page 19: ...air Blockage in flue or wrong flue Electrode position Cabling disconnections Combustion calibration Electronic board Gas valve failure 1 Call for authorised service E 92 Air compensation active Boiler...

Page 20: ...ctrode Electrode position Combustion calibration 1 Call for authorised service E 96 Flue or air suction way blockage Boiler does not work E96 error code flashing on the screen Blockage in flue Blockag...

Page 21: ...oximately 6 power saving with every degree of temperature decrease Ventilation Do not leave windows slightly open for ventilating room rooms In such case continuous heat loss will occur and not having...

Page 22: ...22 warmhaus com...

Page 23: ...nt have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold...

Page 24: ...and 24 hour emergency line immediately or 1850 20 50 50 Don t assume somebody else has reported the smell Carbon monoxide information For further Information on carbon monoxide call 1850 79 79 79 The...

Reviews: