13
warmhaus.com
A
Below an opening
300
Check - 2
B
Above an opening
300
Check - 2
C
Horizontally to an opening
300
D
Below gutters, soil pipes or drainpipes
75
Check - 1
E
Below Eaves
200
Check - 1
F
Below balcony or car port roof
300
Check - 1
G
From a vertical drainpipe or soil pipe
150
H
From an internal or external corner or to a boundary alongside the terminal
300
I
Above ground, roof or balcony level
300
J
From a surface or a boundary facing terminal
600
K
From a terminal facing the terminal
1200
L
From an opening in the car port into the building
1200
M
Vertically from a terminal on the same wall
1500
N
Horizontally from a terminal on the same wall
300
P
From a structure on the roof
N/A
Please see ref AP233
Q
Above the highest point of intersection with the roof
300
2.9. FLUE TERMINAL POSITION