27
warmhaus.com
3.16.1. External Control Connection / Low Voltage Installation
CAUTION
THE GREEN CONNECTIONS ON OUR TERMINAL CONNECTOR OUR LOW
VOLTAGE AND 240V MUST NOT BE CONNECTED TO THESE.
REPLACE WITH
THE LOW VOLTAGE AND 240V MUST NOT BE CONNECTED TO THE GREEN
CONNECTIONS ON THE TERMINAL CONNECTOR.
If your external controls have a 240 V output then please use our 240 V
relay connector supplied with the boiler.
To connect your low voltage external control, remove the green link wire
and connect your two external control cables to the two green wires on the
terminal connector.
3.16.2. External Control Connection / Low Voltage Installation
CAUTION
To connect your 240v external control, remove the green link wire on the
boiler terminal connector and connect your two external control cables
onto the power relay LIVE and NEUTRAL connectors supplied with the
power relay.
Then connect the two LOW VOLTAGE cables connected to the power relay
to the green wires on the terminal connector.