14
Apply thread
sealant here
Plate
Coupling
Flared Fitting
1/2" x 2" Nipple
(FIT180)
STEP 4A: (MATCH LIT SYSTEM)
Connect the
new fitting created in Step 4 to the 1/2” coupling located on
the bottom of the aluminum plate. Tighten.
STEP 4C
Drip Leg
STEP 4B: (STANDARD 24 VOLT IGNITION)
Apply thread
sealant here
Coupling
Standard 24 Volt Ignition
Flared Fitting
Plate
1/2" x 2" Nipple (FIT180)
STEP 4C: (PREMIUM 24 VOLT IGNITION)
STEP 4D
Apply thread sealant here
Coupling
Premium 24 Volt Ignition
Drip Leg
Flared Fitting
Plate
1/2" x 2" Nipple (FIT180)
1/2" x 2" Nipple
(FIT180)
STEP 5A:
(MATCH LIT SYSTEM)
Connect
3/4” flex line to the fitting now located on the bottom of the
aluminum plate.
Coupling
Flex Line
Flared Fitting
STEP 5c
STEP 5B: (STANDARD 24 VOLT IGNITION)
Coupling
Flex Line
Flared Fitting
Standard 24 Volt Ignition
Drip Leg
Plate
1/2" x 2" Nipple
(FIT180)
STEP 5d
STEP 5C: (PREMIUM 24 VOLT IGNITION)
Coupling
Flex Line
Flared Fitting
Premium 24 Volt Ignition
Drip Leg
Plate
1/2" x 2" Nipple
(FIT180)
121K - 249K BTU Systems with FLKV34 and FLKV34FIT180
Plate