21
300K+ BTU Match Lit System with
3/4" Dual Flex Lines (DFLKV34) or
3/4" Dual Flex Lines + FIT300 (DFLKV34FIT300)
Original Series: CFB300, CFB350, CFB450 | H-Style Series: CFBH300, CFBH340
Any custom burners 300K and above
300K+ BTU Systems with DFLKV34 and DFLKV34FIT300
STEP 1- FIT250
STEP 1- FIT250
FIT300: (2) 3/4" x 3" Nipples, (2) 3/4" Tees
STEP 1:
Locate DFLKV34 and FIT300
Parts include two 3/4” flex lines, key valve and keys
(4” and 12”) plus FIT300 Kit.
4” Key
12” Key
Key Valve
Pressure
Face Plate
Flex Lines
FOR PUSH BUTTON IGNITION INSTRUCTIONS: Follow Match Lit System installation instructions. When finished, turn
to page 26 for Push Button Ignition installation instructions.
STEP 1- FIT250
WARNING: Minimum requirement: Incorporate 1 vent on at least two opposing sides (2 vents total) at a minimum size of 18 sq. inches each (Example:
3”x 6” or larger). Installation of the vents in the mid to lower area of the enclosure is recommended. Ventilation allows for heat and/or residual fuel to
escape. Failure to properly vent enclosure may result in the fire pit overheating or explosion. Overheating could lead to heat damage to internal compo-
nents. Some enclosures may require more ventilation based on material, size, and extended use. The vent may serve as a drain as well when installed at
bottom sidewall to prevent water build up. Always consult with local municipality regarding any local code requirements.
WARNING: Ready-to-Finish Kits come with Fire Pit Vent Kit (FPVK). Vents do not come pre-installed on Ready-to-Finish Kit as placement and installation
depends on veneer. Vents to be installed by contractor on site.