background image

8

WARRANTY

ALL BURNERS AND ELECTRONICS (IF PRESENT) MUST BE COVERED 

WHEN NOT IN USE OR WARRANTY IS NULL AND VOID 

Warming Trends™ warrants its products to be free from defective materi-

al and workmanship under normal service and use. This warranty covers 

manufacturing defects only and does not cover defects due to normal 

wear and tear; it does not warrant any product or part that has been al-

tered, accidentally damaged,  damaged in shipping, disassembled, mod-

ifi ed, misused, neglected, failure to maintain, not installed, or not kept in 

continuous service after installation. Warming Trends™ liability shall be 

restricted to the purchase price of the product only and makes no other 

warranty, express or implied, but not limited to, the implied warranties of 

salability and appropriateness for a specifi ed purpose, with respect to its 

products and parts, whether used along or in combination with others. 

Warming Trends™ is free of liability for any damages caused by the unit, 

as well as inconvenience expenses, material or labor charges incurred by 

any service call, repair, removal or re-installation of any unit.  Incidental or 

consequential damages are not covered by this warranty.  Warranty does 

not cover damage to systems due to debris in the gas lines or damage to 

system due to water. Owner is responsible for reading and understanding 

warranty for full terms and conditions

Warming Trends™, at its discretion, agrees to repair or replace defective 

product if returned to Warming Trends™ within the warranty period. The 

respective warranty time periods are effective from the original date of 

purchase. The warranty is non-transferable and applies only to the origi-

nal purchaser. In addition, this warranty is automatically void if the unit’s 

serial number has been removed or altered in any way.

Ignition Systems Warranty 

ALL BURNERS AND ELECTRONICS MUST BE COVERED WHEN NOT IN 

USE OR WARRANTY IS NULL AND VOID

Push Button Ignition Systems

There is no warranty offered on any push button ignition system.

Electronic Ignition Systems

RESIDENTIAL INSTALLATIONS:

24VIK and 3VIK systems are fully warranted for one (1) year with a limited 

warranty for two (2) years from date of purchase. In the event a system 

must be replaced due to a defect/malfunction of the system, Warming 

Trends™ will repair or replace the system at no cost for the fi rst year. 

In the event a system fails after the fi rst year from date of purchase and 

within two years from date of purchase, Warming Trends™will repair or 

replace the system for a cost of 50% of the current list price. This warranty 

does not cover labor costs. 

P24VIK systems purchased ON OR BEFORE April 15, 2018 are fully 

warranted for one (1) year with a limited warranty for two (2) years from 

date of purchase. In the event a system must be replaced due to a defect/

malfunction of the system, Warming Trends™ will repair or replace the 

system at no cost for the fi rst year. In the event a system fails after the fi rst 

year and within two years of date of purchase, the cost for a replacement 

system is at a discount rate of 50% of the current listed price. This warran-

ty does not cover labor costs. 

P24VIK Systems purchased AFTER April 15, 2018 are fully warranted 

for three (3) years from date of purchase. In the event a system must be 

replaced due to a defect/malfunction of the system, Warming Trends™ 

will repair or replace the system at no cost for the fi rst three years.  This 

warranty does not cover labor costs.

COMMERCIAL INSTALLATIONS:

24VIK and 3VIK systems are fully warranted for six (6) months from date 

of purchase. In the event a system must be replaced due to a defect/

malfunction of the system, Warming Trends™ will repair or replace the 

system at no cost. This warranty does not cover labor costs. 

P24VIK systems purchased ON OR BEFORE April 15, 2018 are fully 

warranted for six (6) months from date of purchase. In the event a system 

must be replaced due to a defect/malfunction of the system, Warming 

Trends™ will repair or replace the system at no cost. This warranty does 

not cover labor costs. 

P24VIK Systems purchased AFTER April 15, 2018 are fully warranted 

for one (1) year from date of purchase. In the event a system must be 

replaced due to a defect/malfunction of the system, Warming Trends™ 

will repair or replace the system at no cost for 12 months from the date of 

purchase.  This warranty does not cover labor costs.

__________________________________________________________________

EXAMPLE OF SERIAL NUMBER LABELS (Example only - actual 

label may vary)

Certifi ed

Non-Certifi ed

Problems in the functioning of the systems due to gas plumbing or 

electrical installed by others are not covered by any warranty offered by 

Warming Trends.

No dealer, distributor, or other person has the authority to represent 

or warrant a Warming Trends™ product beyond the terms contained 

within this warranty, and Warming Trends™ assumes no liability for such 

warranty representations. Any questions concerning this warranty should 

be directed to the Warming Trends™ corporate offi ce.

Return Policy of Warranty Product

Any Warming Trends™ product deemed by Warming Trends™ as defec-

tive and covered by the warranty may be returned to Warming Trends™ 

for assessment to determine if repair or replacement is necessary. In 

order to return a product, you must have a Return Merchandise Authori-

zation number (RMA#). Please contact a Warming Trends™ representa-

tive at the corporate offi ce to obtain an RMA#. All returned merchandise 

must have the RMA# clearly printed on the outside of the package.  Re-

turn shipping costs are the purchaser’s responsibility. Warming Trends™ 

is not responsible for product damaged or lost in transit. It is recom-

mended that return items are shipped via a delivery service that can be 

tracked and/or insured to confi rm receipt. 

Summary of Contents for CFB60 2XL NG

Page 1: ...1 INSTALLATION MANUAL For the CROSSFIRETM Brass Burners and Ignition Systems www Warming Trends com 303 346 2224 info warming trends com B R A S S B U R N E R S...

Page 2: ...s match lit Model CFBL90 NG LP as match lit Model CFBL110 NG LP as match lit Model CFBL130 NG LP as match lit Model CFBL150 NG LP as match lit Model CFBL190 NG LP as match lit Model CFBL210 NG LP as m...

Page 3: ...h P24VIKSCCG Model CFBT110 NG LP with P24VIKSCCG Model CFBT170 NG LP with P24VIKSCCG Model CFBT230 NG LP with P24VIKSCCG Model CFBT290 NG LP with P24VIKSCCG 24 VOLT PREMIUM ELECTRONIC IGNITION SYSTEMS...

Page 4: ...please follow Fixed piping system The National Fuel Gas Code ANSI Z223 1 NFPA 54 or International Fuel Gas Code Electrical ground The National Electrical Code ANSI NFPA 70 WARNING Only use gas fuel t...

Page 5: ...WARNING Read all warnings prior to installing your fire feature WARNING All gas products should be installed by qualified profes sionals that are locally licensed by the authority having jurisdiction...

Page 6: ...inside enclosure WARNING Use only your hand to turn the gas key valve Never use tools If the key valve will not turn by hand don t try to repair it Call a qualified technician Force or attempted repa...

Page 7: ...ngsoftbrush Becareful notto damagethehot wire element Placelava rockorglassbackasexplainedintheSectionMedia Installa tioninOwnersInstallationManual Visualinspectionof pilotandpilotassembly Thepilotass...

Page 8: ...e to a defect malfunction of the system Warming Trends will repair or replace the system at no cost for the first year In the event a system fails after the first year and within two years of date of...

Page 9: ...Series CFBH120 Any custom burners between 60K 120K FOR PUSH BUTTON IGNITION INSTRUCTIONS Follow Match Lit System installation instructions When finished turn to page 26 for Push Button Ignition insta...

Page 10: ...nt here Plate Coupling Flared Fitting STEP 3D STEP 3D PREMIUM 24 VOLT IGNITION Coupling Flared Fitting Premium 24 Volt Ignition Drip Leg Plate Apply thread sealant here STEP 3C STEP 3C STANDARD 24 VOL...

Page 11: ...o the fitting now located on the bottom of your aluminum plate Coupling Flex Line Flared Fitting STEP 4B 3 VOLT IGNITION STEP 4b Coupling Flex Line Plate Flared Fitting 3 Volt Ignition Drip Leg STEP 4...

Page 12: ...ignition into transformer FINAL SET UP STEP 6B 3 VOLT IGNITION Drip Leg Coupling 3 Volt Gas Valve Flex Line Plate Flared Fittings Key Valve Key In Gas Line In STEP 6C STANDARD 24 VOLT IGNITION Drip L...

Page 13: ...e Face Plate Flex Line STEP 1 Locate FLKV34 Parts include 3 4 flex line key valve and keys 4 and 12 inch and FIT180 WARNING Minimum requirement Incorporate 1 vent on at least two opposing sides 2 vent...

Page 14: ...4D Apply thread sealant here Coupling Premium 24 Volt Ignition Drip Leg Flared Fitting Plate 1 2 x 2 Nipple FIT180 1 2 x 2 Nipple FIT180 STEP 5A MATCH LIT SYSTEM Connect 3 4 flex line to the fitting n...

Page 15: ...red Fitting Plate Key Valve Flared Fitting Gas In Key In STEP 7B STANDARD 24 VOLT IGNITION Coupling Key Valve Plate Standard 24 Volt Ignition Drip Leg Gas Line In Key In Flex Line Flared Fittings 1 2...

Page 16: ...IT250 Kit 4 Key 12 Key Key Valve Pressure Face Plate Flex Lines 250K 299K BTU Systems with DFLKV34 and DFLKV34FIT250 WARNING Minimum requirement Incorporate 1 vent on at least two opposing sides 2 ven...

Page 17: ...STANDARD 24 VOLT HIGH CAPACITY IGNITION SEE PAGE 20 FOR INSTALLATION INSTRUCTION STEP 3c STEP 3C PREMIUM 24 VOLT STANDARD CAPACITY IGNITION Coupling Apply thread sealant here Drip Leg Plate Premium 2...

Page 18: ...4 Tee FIT250 Plate Plate STEP 4A Connect one 3 4 tee fitting to the connection made in Step 3 1 2 x 3 4 reducing fitting to the 1 2 coupling under aluminum pan STEP 4 Apply thread sealant here 3 4 Tee...

Page 19: ...IUM 24 VOLT IGNITION Same as above Flared Fitting Flared Fitting Apply thread sealant here Apply thread sealant here 3 x 3 4 Pipe Nipple FIT250 Key Valve 3 4 Tee FIT250 STEP 8 Connect remaining 3 4 te...

Page 20: ...x Line Flex Line Key Valve Key In Gas In STEP 11 STANDARD 24 VOLT AND PREMIUM 24 VOLT IGNITION SYSTEMS ONLY Plug ignition into three prong above grade NEMA Rated outdoor specific GFCI electrical outle...

Page 21: ...ent Incorporate 1 vent on at least two opposing sides 2 vents total at a minimum size of 18 sq inches each Example 3 x 6 or larger Installation of the vents in the mid to lower area of the enclosure i...

Page 22: ...FIT300 STEP 3B STANDARD 24 VOLT IGNITION STEP 3C PREMIUM 24 VOLT IGNITION Coupling Coupling Plate Plate Drip Leg Drip Leg 3 4 x 3 Nipple FIT300 3 4 x 3 Nipple FIT300 Apply thread sealant here Apply t...

Page 23: ...ion Plate STEP 5C PREMIUM 24 VOLT IGNITION STEP 5c Coupling 3 4 Tee FIT300 3 4 x 3 Nipple FIT300 Flared Fitting Flared Fitting Premium 24 Volt Ignition Drip Leg Plate Apply thread sealant here Apply t...

Page 24: ...ere Apply thread sealant here Flared Fitting Flared Fitting 300K BTU Systems with DFLKV34 and DFLKV34FIT300 STEP 6A Connect both 3 4 flex lines to the 3 4 flared fittings connected in Step 5 Tighten 3...

Page 25: ...specific GFCI electrical outlet or have electrician hardwire ignition into transformer FINAL SET UP Coupling Flared Fitting Flared Fitting Flared Fitting Flared Fitting Flex Line Flex Line Drip Leg Pr...

Page 26: ...from the inside edge of the jet NOTE If Spark Igniter is too high when ush with plate run mechanism up through bottom of plate 125 125 STEP 1 To place Spark Igniter in proper position the installer wi...

Page 27: ...bracket 7 Insert AAA battery into button stem 8 Screw on button cover Mounting Bracket Button Stem WARNING Minimum requirement Incorporate 1 vent on at least two opposing sides 2 vents total at a min...

Page 28: ...lve KV12 or KV34 Pressure Face Plate KV12 or KV34 Flex Line FL3612 or FL3634 Flared Fitting Flared Fitting 12 Key KEY12 4 Key KV12 or KV34 Parts Glossary Spark Igniter PB SI Push Button Module PB CM S...

Page 29: ...to two 3 4 Flex Lines and two 3 4 Flex Lines to 3 4 Key Valve FL3612 36 Lx 1 2 Diameter Flex Line MM KV12 1 2 Key Valve 4 Key KEY12 12 Key DRIPLEG12 1 2 Drip Leg Kit LPRH LP Regulator mounted on 3 8 1...

Reviews: