14 June 2016 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. 

All Dimension are in mm 

 

 

 

 

 

Total Coals 

Top 

Bottom 

Top 

Bottom 

Model 

Total 

SG 700 

22 

SG 780  

28 

SG 900 

10 

38 

SG 1100 

10 

11 

42 

Number of Coals per Row 

Number of Rows 

Gloves should be worn when handling Ceramic Fibre Coals & Logs: care needs to be taken when handling Coals & Logs, Due to the Carbon on the 
Coals can stain the surroundings. 

HELPFUL HINTS:  When Hot use  Metal Tongs

Apply a thin layer of Vermiculite over the Burner, just enough to cover the Burner Tray only as shown above. 

1: Bottom Row 

: Assemble 2 Bottom Rows of Coals onto the Vermiculite Base.   

2: Top Row 

: Assemble 2 Top Rows of Coals onto the Bottom Row. 

 

 

 

 

 

 

 

 

 

 

Each Coal randomly positioned with the Torn (roughest) Face Outward. 

Ensure Coal positioning does not directly block the 3 Flame Pilot.

 

The placement of the Coals & Logs may vary to make an even Flame Pattern.   

 

 

 

 

 

Logs and Twigs may be scattered to achieve best Visual Effect. 

Fit Burner Grate by sliding R & L Side Metal Pins on Grate, into Holes Located on Burner Side Plates, as shown below.   

2: Top  Row 

Slide R & LH Grate 
Pins into Holes located 
on the Burner Side 
plates . 

1: Bottom Row 

COALS AND LOGS                       (To be set by Gasfitter)

 

VERMICULITE (COURSE)           (To be set by Gasfitter)               

 

Model SG780 Shown: Total number of coals will vary per model. 

General Coal orientation fro optimum effect. 

APPLYING THE VERMICULITE : 

(Coarse—must be larger than the burner plates holes so not to block them) 

 

Apply with care a thin layer of Vermiculite over the Burner, just enough to cover the Burner Tray only. 

NOTE: If the burner flame is uneven, the Vermiculite may need to be changed or sifted to remove the smaller pieces that can block the burners 
holes. The smaller pieces can, cause uneven burn and the unit to run dirty. 

Summary of Contents for SG 1100

Page 1: ...ion The Warmington unit is to be installed by a certified Warmington installer or an approved NZHHA installation technician See www homeheat co nz members for a certified NZHHA SFAIT Installer in your...

Page 2: ...on the pressure difference from inside the building to the outside A lower pressure in the building may induce a draft down the flue system and back into the building causing the fire to smoke or spil...

Page 3: ...rner Width A 674 754 874 1074 Burner Height B 205 205 205 205 Burner Depth C 272 272 272 272 Flue Diameter Min J 200 200 250 250 Flue CSA mm K 31 416 31 416 49 087 49 087 WARMINGTON BURNERS NOTE IMPOR...

Page 4: ...ctor Size mm 2 X 1 1mm 2 X 1 2mm 2 X 1 3mm 2 X 1 4mm Burner Pressure High kPa 2 5 2 5 2 5 2 5 Burner Pressure Low kPa 0 75 0 75 0 75 0 75 MJ h 29 38 42 50 Flame Effect Output Only Effect Effect Effect...

Page 5: ...hat the Gas Type Specified on the Data Plate is correct for the available supply LPG or NG A Copper Gas supply capable of supplying the correct MJ h should be brought into the rear of the Installation...

Page 6: ...roughest Face Outward Ensure Coal positioning does not directly block the 3 Flame Pilot The placement of the Coals Logs may vary to make an even Flame Pattern Logs and Twigs may be scattered to achie...

Page 7: ...ng the Switch in a Depressed State repeat steps 2 3 if necessary Once the Pilot Flame is lit hold this position for 3 5 seconds release from the Depressed State before setting the Flame Control to Ful...

Page 8: ...rol Valves are Factory Set but may require adjustment onsite Turn Appliance Off Remove Front Plastic Cover on Igniter Pull Cover to Slide off Unscrew Test Nipple on the Burner Manifold fit the Test Ga...

Page 9: ...es on the principle of dual radiant and convected heat Therefore it is important to observe the following precautions associated with any heating appliance or open fire Do not cover or restrict the fi...

Page 10: ...adjust to Low Flame and check pres sure NOTE If setting the Pressure is required it is to be carried out by a Certified Gas Fitter If adjustments are necessary remove the cap The Pressure Adjustment S...

Page 11: ...serviced annually and any service operation must be carried out by a qualified service person WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AU...

Reviews: