background image

14 June 2016 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. 

All Dimension are in mm 

HEARTH CLEARANCES

 

Note: For Combustible Floors 

 
Minimum Hearth of 300mm  (A) must be 
maintained at any given height. 
 

* Inlet Pressure not to exceed 4.0KPa

 

GAS SPECIFICATIONS                  Tested to current gas standards

 

NOTE : All Test Pressures are tested by a Independent Test Lab

 

MODLE 

SG 700

 

SG 780

 

SG 900

 

SG 1100

 

LPG

 

 

 

 

 

Nominal Pressure kPa

 

2.75 kPa

 

2.75 kPa

 

2.75 kPa

 

2.75 kPa

 

Nominal Injector Size mm 

2 X 1.1mm 

2 X 1.2mm 

2 X 1.3mm 

2 X 1.4mm 

Burner Pressure High kPa 

2.5 

2.5 

2.5 

2.5 

Burner Pressure Low kPa 

0.75 

0.75 

0.75 

0.75 

MJ/h

 

29

 

38

 

42

 

50

 

Flame Effect Output Only

 

Effect

 

Effect

 

Effect

 

Effect

 

Supply Pipe Size dia—min 

3/8” 

3/8” 

1/2” 

1/2” 

Natural Gas

 

 

 

 

 

 

 

 

 

Nominal Pressure kPa

 

1.5 kPa

 

1.5 kPa

 

1.5 kPa

 

1.5 kPa

 

Nominal Injector Size mm 

2 X 1.8mm 

2 X 2mm 

2 X 2.2mm 

2 X 2.4mm 

Burner Pressure High kPa 

1.0 

1.0 

1.0 

1.0 

Burner Pressure Low kPa 

0.3 

0.3 

0.3 

0.3 

MJ/h

 

35

 

41

 

48

 

60

 

Flame Effect Output Only

 

Effect

 

Effect

 

Effect

 

Effect

 

Supply Pipe Size dia—min 

3/8” 

1/2” 

1/2” 

1/2” 

IMPORTANT NOTES : 

 

Lab. Test No 

GL 923 

GL 900 

GL 834 

GL 876 

Lab. Test Dates

 

20/04/2010

 

26/02/10

 

26/06/09

 

24/12/09

 

ESS Declaration No: 

1149420106 

1149520106 

1149720106 

1149820106 

Summary of Contents for SG 700

Page 1: ...ion The Warmington unit is to be installed by a certified Warmington installer or an approved NZHHA installation technician See www homeheat co nz members for a certified NZHHA SFAIT Installer in your...

Page 2: ...on the pressure difference from inside the building to the outside A lower pressure in the building may induce a draft down the flue system and back into the building causing the fire to smoke or spil...

Page 3: ...rner Width A 674 754 874 1074 Burner Height B 205 205 205 205 Burner Depth C 272 272 272 272 Flue Diameter Min J 200 200 250 250 Flue CSA mm K 31 416 31 416 49 087 49 087 WARMINGTON BURNERS NOTE IMPOR...

Page 4: ...ctor Size mm 2 X 1 1mm 2 X 1 2mm 2 X 1 3mm 2 X 1 4mm Burner Pressure High kPa 2 5 2 5 2 5 2 5 Burner Pressure Low kPa 0 75 0 75 0 75 0 75 MJ h 29 38 42 50 Flame Effect Output Only Effect Effect Effect...

Page 5: ...hat the Gas Type Specified on the Data Plate is correct for the available supply LPG or NG A Copper Gas supply capable of supplying the correct MJ h should be brought into the rear of the Installation...

Page 6: ...roughest Face Outward Ensure Coal positioning does not directly block the 3 Flame Pilot The placement of the Coals Logs may vary to make an even Flame Pattern Logs and Twigs may be scattered to achie...

Page 7: ...ng the Switch in a Depressed State repeat steps 2 3 if necessary Once the Pilot Flame is lit hold this position for 3 5 seconds release from the Depressed State before setting the Flame Control to Ful...

Page 8: ...rol Valves are Factory Set but may require adjustment onsite Turn Appliance Off Remove Front Plastic Cover on Igniter Pull Cover to Slide off Unscrew Test Nipple on the Burner Manifold fit the Test Ga...

Page 9: ...es on the principle of dual radiant and convected heat Therefore it is important to observe the following precautions associated with any heating appliance or open fire Do not cover or restrict the fi...

Page 10: ...adjust to Low Flame and check pres sure NOTE If setting the Pressure is required it is to be carried out by a Certified Gas Fitter If adjustments are necessary remove the cap The Pressure Adjustment S...

Page 11: ...serviced annually and any service operation must be carried out by a qualified service person WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AU...

Reviews: