14 June 2016
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
All Dimension are in mm
4
HEARTH CLEARANCES
Note: For Combustible Floors
Minimum Hearth of 300mm (A) must be
maintained at any given height.
* Inlet Pressure not to exceed 4.0KPa
GAS SPECIFICATIONS Tested to current gas standards
NOTE : All Test Pressures are tested by a Independent Test Lab
MODLE
SG 700
SG 780
SG 900
SG 1100
LPG
Nominal Pressure kPa
2.75 kPa
2.75 kPa
2.75 kPa
2.75 kPa
Nominal Injector Size mm
2 X 1.1mm
2 X 1.2mm
2 X 1.3mm
2 X 1.4mm
Burner Pressure High kPa
2.5
2.5
2.5
2.5
Burner Pressure Low kPa
0.75
0.75
0.75
0.75
MJ/h
29
38
42
50
Flame Effect Output Only
Effect
Effect
Effect
Effect
Supply Pipe Size dia—min
3/8”
3/8”
1/2”
1/2”
Natural Gas
Nominal Pressure kPa
1.5 kPa
1.5 kPa
1.5 kPa
1.5 kPa
Nominal Injector Size mm
2 X 1.8mm
2 X 2mm
2 X 2.2mm
2 X 2.4mm
Burner Pressure High kPa
1.0
1.0
1.0
1.0
Burner Pressure Low kPa
0.3
0.3
0.3
0.3
MJ/h
35
41
48
60
Flame Effect Output Only
Effect
Effect
Effect
Effect
Supply Pipe Size dia—min
3/8”
1/2”
1/2”
1/2”
IMPORTANT NOTES :
Lab. Test No
GL 923
GL 900
GL 834
GL 876
Lab. Test Dates
20/04/2010
26/02/10
26/06/09
24/12/09
ESS Declaration No:
1149420106
1149520106
1149720106
1149820106