background image

5 April 2019

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

All Dimension are in mm

………….

Copyright © 

 

3

 

Freestanding 
Square Twin firebox

 

 

 

SI 780 

 

FST

 

SI 780T

 

FST

 

SI 900

 

FST

 

SI 1100

 

FST

 

Firebox Width 

A

 

780

 

780

 

900

 

1100

 

Firebox Height 

B

 

600

 

680

 

750

 

800

 

Firebox Depth 

C

 

710

 

710

 

860

 

910

 

Flange Width 

D

 

830

 

830

 

950

 

1150

 

Flange Height 

E

 

625

 

705

 

775

 

825

 

Adaptor Height 

F

 

205

 

205

 

275

 

275

 

Cabinet Height 

G

 

850

 

930

 

1060

 

1110

 

Cabinet Depth 

H

 

698

 

698

 

848

 

898

 

Cabinet Width 

I

 

830

 

830

 

950

 

1150

 

Cabinet Front Height 

J

 

625

 

705

 

775

 

825

 

Flue 

K

 

300

 

300

 

325

 

350

 

Inner Baffle 

L

 

350

 

350

 

375

 

400

 

Outer Liner 

 

400

 

400

 

425

 

450

 

Heat Output

 

kW

 

  

 

  

  

Peak*

 

 

 

24

 

26

 

32

 

35

 

Range*

 

 

 

15

-

17

 

17

-

19

 

18

-

21

 

19

-

22

 

*Estimated unless stated otherwise.

 

WARMINGTON FIREBOX DIMENSION

 

Minimum flue height

 

 

 

flue height

 

4800

 

measured from top of adaptor

 

B + F + 4800

 

FIREBOX FREESTANDING TAPER TOP CABINET

 

Adaptor fitting

 

    Seal adaptor to firebox using high-temp gasket sealant. Bolt  
     through holes provided.

 

Seismic Restraint

 

Secure firebox through anchor positions provided.

 

Assembly Check List

 

 

Tick Box

 

Firebox

 

 

 

Freestanding cabinet

 

 

Adaptor (fastenings)

 

 

 

Ash Pan

 

 

 

Bricks

 

 

 

Louvres

 

 

 

Badge

 

 

 

Damper handle

 

 

 

Specifications

 

 

Packed By

 

 

 

Freestanding

 

Taper Top Cabinet

 

Seismic 

 

restraint

 

located under 

bricks

 

Summary of Contents for SI 1100FST

Page 1: ...nd current Installation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician See www homeheat co nz members for a Certified NZHHA SFAIT Installer in your area IMPORTANT Read all the Instructions carefully before commencing the Installation Failure to follow these Instructions may result ...

Page 2: ...f the land in relation to the home has a bearing on how the wind will interact with the fire and flue system Care needs to be taken to ensure that the flue termination is in the correct position to maximise performance The Prevailing Wind Care needs to be taken to ensure that the flue termination is in the correct position as wind and gusts that hits the flue and cowl system may overcome the cowl ...

Page 3: ... 950 1150 Cabinet Front Height J 625 705 775 825 Flue K 300 300 325 350 Inner Baffle L 350 350 375 400 Outer Liner 400 400 425 450 Heat Output kW Peak 24 26 32 35 Range 15 17 17 19 18 21 19 22 Estimated unless stated otherwise WARMINGTON FIREBOX DIMENSION Minimum flue height flue height 4800 measured from top of adaptor B F 4800 FIREBOX FREESTANDING TAPER TOP CABINET Adaptor fitting Seal adaptor t...

Page 4: ...h and plinth details 3 Fit the firebox cabinet into position Remove the cabinet top bolt the firebox to the plinth or through to the floor with the bolting points provided on the left and right hand sides of the firebox seismic restraints 4 Ensure that Hi Temp Sealant is used between the Fire and Adaptor Bolt into position with the Bolts in the Left and Right Hand Sides of the Firebox 5 Install th...

Page 5: ...ce place Caitec weir vent system as close to fireplace as possible CAITEC TECHONOLGY ROOM AIR REPLACEMENT Caitec draws air from an external air source to ensure that combustion air the open fire uses is replaced maintaining the home at a constant pressure equilibrium reducing the risk of back drafting Ensure that the home is vented to outside fresh Air 2 x 100mm diameter vents are required or equi...

Page 6: ... 335 Hearth Depth O 1910 1910 2060 2110 Hearth Width P 1200 1200 1350 1550 Hearth Projection Q 600 600 600 600 PLAN VIEW OF CABINET CLEARANCES STRAIGHT WALL HEARTH Adaptor fitment Seal adaptor to firebox using high temp gasket sealant Bolt through holes supplied Seismic Restraints Secure fire down through seismic Restraints Hearth Plinth construction For combustible flooring an insulating Hearth P...

Page 7: ...01 4 9 1 6 NOTE The last length of flue pipe needs to extend past the liner so that when the top spide and flashing cone are fitted the flashing cone and the flue pipe are flush or that the flue pipe is 5mm lower that the lashing cone 7 Fit the top Spider into position ensure that the legs of the spider are fitted inside the liner and the spider is positioned hard down onto the liner and tighten w...

Page 8: ...ing Butynol Dek tite an additional flue pipe baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 All external air vents and ceiling penetrations are to be vermin and rodent proof Note FLUE SYSTEMS casing Flue system may require to be eoubled lined to comply Ref ASNZS 2918 2001 4 3 rlue pipe casing Freesta...

Page 9: ...t 9 CHIMNEY CHASE FLASHING AND AIR VENTILATION OPTIONS VENTING THROUGH CHIMNEY CHASE VENTING THROUGH FLASHING No Insulation under flashing Insulation under flashing CHIMNEY CHASE FLASHING DETAILS Note Flashing spigot height is determined by the insulation that is fitted under the flashing See details at bottom of page STEP 1 STEP 2 STEP 3 SETTING ADD COWL AND FLASHING CONE HEIGHT ...

Page 10: ... Dimension are in mm Copyright 10 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System The flue exit is to comply to ASNZS 2918 2001 3D View Note FLUE SYSTEMS casing Flue system may require to be Doubled lined to comply Ref ASNZS 2918 2001 4 3 Flue pipe casing ...

Page 11: ...in mm Copyright 11 RAISED HEARTH CLEARANCES Note A minimum height must be maintained from the top of the cabinet to the ceiling See page 8 SI 780 1100 RAISED HEARTH CLEARANCES Note For combustible floors a minimum hearth of 380mm A must be main tained When raising cantilever ing a hearth ensure the hearth is appropriately engineered to take the weight of the hearth ...

Page 12: ...INGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING WARNING DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES WARN...

Reviews: