14 August 2019
All dimensions are in mm
Copyright
11
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
FLUE HEIGHT MINIMUM DETAILS
The flue exits are to comply to ASNZS 2918: 2001
3D View
Note: FLUE SYSTEMS Casing
….
Flue system may require to be Doubled lined to comply.
Ref ASNZS:2918:2001 4.3 Flue pipe casing.
Increase from 1000 mini-
mum until clear within
3000mm of flue top
Increase as necessary until
no nearby structures/objects
are within 3000mm of flue top
FRAME OUT - TRIM OUT DETAILS FOR FLUE SYSTEM
Note:
External Requirements
Refer to AS/NZS2918:2001 4.9.1
Install Flue system to AS/NZS2918:2001
When using a rubber or Bitumen flashing (Butynol,
Dectite) an Additional Flue pipe Baffle is required.
All external air vents & ceiling penetrations must
be bird proofed with permanently fixed screens.
All flashing to comply with E2.