14 August 2019

 

All dimensions are in mm

 

Copyright

 

6

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

INSTALLATION

 

Important Notes:

 

• 

This is a general installation guide only. Contact a 

NZHHA Installer

” 

for installation advice or go to 

www.homeheat.co.nz

, then select Members & 

follow instructions to find a certified NZHHA SFAIT installer.

 

• 

Install to AS/NZS 2918:2001.

 

• 

Install to manufacturer

s specifications.

 

• 

All new installations require a permit.

 

Description

 

 

 

Lewis

 

Lindis

 

McKenzie

 

Firebox width

 

A

 

580

 

660

 

660

 

Firebox depth

 

B

 

580

 

580

 

680

 

Firebox height

 

C

 

860

 

860

 

860

 

Flue diameter

 

D

 

150

 

150

 

150

 

To flue centre

 

E

 

191

 

191

 

191

 

Ceiling height

 

F

 

2400

 

2400

 

2400

 

Minimum from fire to ceiling

 

G

 

1500

 

1500

 

1500

 

Total height from floor protector

 

H

 

4600

 

4600

 

4600

 

Internal firebox depth

 

VV

 

385

 

385

 

485

 

Internal firebox height

 

WW

 

250

 

255

 

255

 

Internal firebox width 

 

XX

 

360

 

430

 

430

 

Emission level (g/ kg)

 

 

0.81

 

1.19

 

1.46

 

FIREBOX DIMENSIONS

 

Minimum Flue Height

 

Flue height

 

3600

 

Measured from top of cabinet

 

C + 3600

 

Floor Protection

 

Floor

 protectors are normally designed to suit each individual 

setting

”.

 

The Southern Series requires a 

ASH ONLY

” 

floor protector as needed 

for some types of wood burners.

 

Summary of Contents for Southern Series

Page 1: ...ASNZS 2918 2001 Building Code C AS1 7 5 Open Fires Keep these instructions for further reference Ensure that you have the correct and current installation details for the Warmington Fire Installation...

Page 2: ...ices LTD TESTED TO AS NZS 4013 BURN ONLY UNTREATED WOOD WITH MOISTURE CONTENT LESS THAN 25 DRY BASIS AVERAGE PARTICULATE EMMISSION FACTOR BURNING SOFTWOOD 1 19 g kg MAXIMUM AVERAGE HEAT OUTPUT BURNING...

Page 3: ...for long periods Clean air testing is conducted with the door closed Contact with your local territorial authority to check for local compliance Glass Door When in operation the full beauty of the co...

Page 4: ...is fully established and burning brightly the air supply can be considerably reduced to control heat output and fuel consumption Note the air control is designed such that even when fully closed some...

Page 5: ...is recommended to be done annually before each winter Firebox Maintenance Keep your stove clean by polishing all over with a soft cloth when unit is cool In humid climates more interior firebox corros...

Page 6: ...cription Lewis Lindis McKenzie Firebox width A 580 660 660 Firebox depth B 580 580 680 Firebox height C 860 860 860 Flue diameter D 150 150 150 To flue centre E 191 191 191 Ceiling height F 2400 2400...

Page 7: ...centre O 363 391 425 Hearth depth P 1129 1169 1318 To wall side Q 66 66 100 Hearth projection R 616 616 716 To flue centre S 513 553 601 Measurement taken from front ash lip Measurement taken from flu...

Page 8: ...ons and operation WARNING DO NOT CONNECT TO AN UNVENTED HOT WATER SYSTEM Install in accordance with AS3500 4 1 or NZS4603 and the appropriate requirements of the relevant building code or codes Wet Ba...

Page 9: ...This is the same for both bricks on each side Note The Lewis and Lindis are supplied with 2 x firebricks one each side The McKenzie is supplied with 4x firebricks 2x large 240x240mm and 2x small 240x...

Page 10: ...ing to seal onto the roofing material Assemble Flue Pipes together ensuring seams are in line Secure each joint with three rivets or self tapping screws Flue Pipes must be assembled with crimped ends...

Page 11: ...ASNZS 2918 2001 4 3 Flue pipe casing Increase from 1000 mini mum until clear within 3000mm of flue top Increase as necessary until no nearby structures objects are within 3000mm of flue top FRAME OUT...

Page 12: ...NSTALLED IN ACCORDANCE WITH AS NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES WARNING APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQU...

Reviews: