background image

16 December 2014 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. 

 

All Dimension are in mm……….Copyright 

Solid Fuel Burner, Traditional Brick Built Open Fire.

 

Installation Instructions

 

Traditional 800-1000-1200 Open Fire  

 
                                                  

 

 

Visit 

www.warmington.co.nz

 for Spec’s, DWG’s and PDF uploads of fires 

 

Fire, flue system and instructions to comply with ASNZS 2918:2001 & Building Code C/AS1 7.5 Open Fires 

 

Keep these Instructions for further reference……Ensure that you have the correct and current installation details for the Warmington Fire 

 

Installation

 

The Warmington unit is to be installed by a certified Warmington installer or an Approved NZHHA Installation Technician. 

 

 

 

 

IMPORTANT 

Read all the instructions carefully before commencing the Installation. Failure to follow these instructions may result in a fire hazard and void the warranty 

NOTE ON TRAD. FIRES 

 
Like the Traditional Brick 
Back Fire of yesteryear, the 
Warmington Traditional Fire 
is built with the experience 
and techniques of the past .... 
These make a grand 
statement in the home and 
with the introduction of the 
Gas Log Lighter for ease of 
lighting are simple to 
operate, however they can 
lack in efficiency.

 

Note : Not Included—see page 2: 

 

 

Bricks and Bricklaying 

 

Log Lighter 

 

Grate 

 

Hearth and Plinth 

 

Installation 

 

NOTE : 

Non-Combustible 

Cladding eg : 
10mm Promina Board , 
10mm Supalux ,  
Latex Plaster . 

(Not Supplied) 

NOTE : Traditional Open fires are the least efficient fires available and can lack in Heat output.

 

Note: FLUE SYSTEMS Casing….

 

Flue  system  may  require  to  be  Doubled  lined  to  comply. 
Ref ASNZS:2918:2001 4.3 Flue pipe casing

 

Note: BRICK OUT GUIDE Details….

 

When  purchasing  the  fire  bricks  the  bricking  guide  will 

come with the bricks.

 

Summary of Contents for TF 1200

Page 1: ...carefully before commencing the Installation Failure to follow these instructions may result in a fire hazard and void the warranty NOTE ON TRAD FIRES Like the Traditional Brick Back Fire of yesterye...

Page 2: ...No Log Lighter Control Box 1 NOT Supplied Components are required for Install Priced depending on Requirements No Fire Bricks H40 75X115X230mm Other Sizes Available Varied Fire Brick Refractite Morta...

Page 3: ...pe and position of the land in relation to the home has a bearing on how the wind will interact with the fire and flue system Care needs to be taken to ensure that the flue termination is in the corre...

Page 4: ...ht H 1820 1820 1995 Heat Cell Depth I 865 865 965 To Centre of Flue J 539 538 589 Flue Diameter K 300 300 350 Liner Diameter L 400 400 450 Heat Cell Clearance Width M 1290 1490 1690 Heat Cell Clearanc...

Page 5: ...aved Aerated Concrete AAC Heat cell around the fire A general minimum lay out is shown in this Specification Note Hearth and Plinth Construction For combustible flooring an insulating hearth and plint...

Page 6: ...iameter K 300 300 350 Liner Diameter L 400 400 450 Heat Cell Clearance Width M 1290 1490 1690 Heat Cell Clearance Depth N 990 990 990 Heat Cell Clearance Height O 2150 2150 2150 Hearth Width p 1350 15...

Page 7: ...1800 Hearth Projection Q 500 600 750 Block Clearance Width R 1610 1610 2010 Block Clearance Depth S 1000 1000 1200 Block Enclosure Height T 2390 2390 2390 Chimney Chase Clearance X 500 500 550 BLOCK...

Page 8: ...TF 800 TF 1000 TF 1200 Hearth Width P 1350 1550 1800 Hearth Projection Q 500 600 750 Solid Poured Top Width RR 1590 1990 1990 Solid Poured Top Depth SS 1190 1190 1190 Block Enclosure Height TT 2390 2...

Page 9: ...Heat cell is constructed around the firebox using 75mm Hebel see attached minimum spec below 2400x600x75 Power Panels are required for basic heat cell construction as shown in detail Firebox with Hebe...

Page 10: ...her styles and mix or other styles can be bricked according to your liking Some Bricklayers prefer to us their own Refractite Please Check with the Bricklayer Bricks come in a standard size of 230 x 1...

Page 11: ...mm 17 16 1050 mm 18 17 1110 mm max 19 18 TF 800 Grate TF 1000 Grate TF 1200 Grate TF 1500 Grate Measurements for Wood Grate Sizes A Possible Grate Width 410mm Measuring for the Grate First measure th...

Page 12: ...ange product specifications without prior notification All Dimension are in mm Copyright 12 OPERATION OF DAMPER DAMPER OPEN DAMPER CLOSED Damper Handle To Open Damper Push Damper Handle Up To Close Da...

Page 13: ...mm lower that the Flashing cone 2 Fit the Top Spider into position ensure that the legs of the spider are fitted inside the liner and that the spider is positioned hard down onto the liner and tighten...

Page 14: ...ol Dectite an Additional Flue pipe Baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 Test Report Number...

Page 15: ...t 15 CHIMNEY CHASE FLASHING AND AIR VENTILATION OPTIONS VENTING THROUGH CHIMNEY CHASE VENTING THROUGH FLASHING Insulation under flashing CHIMNEY CHASE FLASHING DETAILS SETTING ADD COWL AND FLASHING CO...

Page 16: ...Dimension are in mm Copyright 16 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System The flue exits are t...

Page 17: ...RANCES Important Note For Raising Trad Fires on Combustible Floors at Dimension B Height of 420mm above the Hearth Extension Dimension A of 380mm must be Maintained This is for all Traditional Fire mo...

Page 18: ...LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING WARNING DO NOT STORE FUEL WITHIN HEATER INSTA...

Reviews: