Instructions for Installation

3.1 Instructions for Mounting  

EMBER panels must be mounted with the supplied original mounting hardware (aluminum profiles at the back of the 

panels and screws included). For panels that are used without the original mounting hardware, the warranty, liability and 

consequential damages are void. 
EMBER panels must only be used in the manufacturer-related frames. 
For panels that are used without the original frame, the warranty, liability and damages are void. 

3.1.2. General Instructions for Mounting 

Depending on the desired application (see Section 1.3.), different types of installation are provided. All EMBER panels come 

with original mounting hardware (aluminum profiles at the backside of the panels and screws for wall/ceiling mounting are 

enclosed). 
•  Make sure that the power plug is not plugged in during assembly. During installation of the unit, also make sure that the 

heating panel is not in the “ON” position.  

•  Do not make any holes in the heating panel. If holes have been made for any reason, do not operate the device. Please 

contact the manufacturer or dealer from whom you purchased the product.  

•  To ensure a quick and easy installation, use the enclosed mounting template and follow the instructions for installation as 

described in detail. 

•  If the device is installed in children’s rooms or rooms accessible to children, make sure that the device is suspended at 

least 4 feet above the ground.  

•  DISTANCE TO BACKSIDE: EMBER panels output convection heat (not infrared radiation) at the backside only. Make sure 

that the distance from the wall to the back of the heating panels (metal/aluminum plate) is at least 1 inch in order to 

ensure ventilation. This distance is always provided when you use the standard mounting hardware. If you use a different 

mounting system than the original, warranty as well as liability for consequential damages is void. 

•  DISTANCE TO FRONTSIDE: EMBER panels send out infrared radiation only on the front side. Make sure that there is a 

minimum distance of 10 inches between the front of the panel and any objects.  

•  Do not mount the heating panel near a shower, tub or swimming pool. Make sure that the heating panel cannot be 

touched by any person who is in the bath or shower. In case of installation in wet rooms, the installation must be done by a 

licensed electrician.

• Never mount the heating element before or immediately below a socket.
•  Make sure that the plug is accessible after installation of the panels and, if needed, can be  immediately pulled.  
•  If the heating panel is integrated in a permanent electrical installation or connection, a correctly sized circuit breaker is 

needed. This connection has to be carried out by a qualified professional. 

Section 3

Summary of Contents for Ember

Page 1: ...Free Design Service 24 7 Installation Support 800 875 5285 www WarmlyYours com Ember Infrared Heating Panels Installation Manual...

Page 2: ...structions 3 2 2 Special Safety Instructions 3 3 Instructions For Installation And Use 4 3 1 Instructions For Mounting 4 3 2 Instructions For First Use 5 3 3 Instructions For Regular Use 6 3 4 Instruc...

Page 3: ...as a very effective impact on people who are restricted in their movement The use of EMBER panels can improve your overall health Due to the low power of the individual plates and a uniform arrangemen...

Page 4: ...systems Please note the necessary details for instructions described in Section 3 1 1 3 2 Wall Panels EMBER wall panels can be optimally used as a supplementary or primary heating system Due to their...

Page 5: ...e heater is very hot when in use depending on model up to 125 C or 257 F Contact could lead to serious burns Each EMBER heater is equipped with a power cord and plug By using an optional adapter you c...

Page 6: ...scribed in detail If the device is installed in children s rooms or rooms accessible to children make sure that the device is suspended at least 4 feet above the ground DISTANCE TO BACKSIDE EMBER pane...

Page 7: ...eating panel to a perfectly placed and installed pair of sockets note the instructions mentioned above for safety Now the heating panel can be put into operation The startup heating time is approximat...

Page 8: ...o achieve the best results when cleaning follow these steps Before cleaning unplug the unit The heater is very hot during use depending on model up to 125 C or 257 F BURNING DANGER Before you clean th...

Page 9: ...information applicable to the EMBER radiant panel line Please find additional information about performance size and surface temperature on the sticker located on the back of the panels Technical Deta...

Page 10: ...ycle the protective film properly The heater or parts thereof may not be disposed with normal household waste but must be taken to a collection point for recycling of electronic and electric devices T...

Page 11: ...that the heating panel to which this declaration relates is compliant with the following guidelines and standards UL 499 2005 R3 11 EN60335 1 CAN CSA C22 2 No 60335 1 11 EN60335 2 30 CAN CSA E60335 2...

Page 12: ...al testing packaged securely in suitable boxes and shipped In order to provide redress for damage during transit we ask that you unpack the heating panel in the presence of the delivering carrier in c...

Page 13: ...ides on all EMBER radiant panels a 5 year warranty from the date of purchase Proof of purchase is a guarantee slip Excluded from the warranty are external optical defects beyond the damage caused by i...

Page 14: ...expense WarmlyYours com Inc will not be liable for the labor required to replace the Radiant Panel The Limited Warranty is null and void if the project owner or his representative attempts to repair t...

Reviews: