1
Bracket Assembly Instructions (continued)
Parts List
A1
tools required
Ø8mm
H
L
3PCS
1-3
- installation should be completed by a suitably qualified person
- please dispose of packaging in a responsible manner
Installation instruction
- Review instructions carefully before installation
4PCS
4PCS
4PCS
3PCS
3PCS
E68 Radiator Installation Instruction
1
Ø8mm
2
1PCS
1PCS
1PCS
1PCS
1PCS
A2
a
b
c
d
e
f
g
h
i
j
k
a
c
d
k
f e
h
g
4PCS
l
A1
tools required
Ø8mm
H
L
3PCS
1-3
- installation should be completed by a suitably qualified person
- please dispose of packaging in a responsible manner
Installation instruction
- Review instructions carefully before installation
4PCS
4PCS
4PCS
3PCS
3PCS
E68 Radiator Installation Instruction
1
Ø8mm
2
1PCS
1PCS
1PCS
1PCS
1PCS
A2
a
b
c
d
e
f
g
h
i
j
k
a
c
d
k
f e
h
g
4PCS
l
A
A
B
B
C
d
e
f
g
h
A
B
C
g
h
A
A
B
B
C
d
e
f
g
h
A
B
C
g
h
2x4
Stu
d
TOOLS REQUIRED
INST
ALLA
TION INSTR
UCTIONS
- Review instructions car
efully befor
e installation
- Installation should be completed by a qualified person
- Please dispose of packaging in a r
esposible manner
1-2.
2-2.
1
2x4
Stud
2
a.
g.
f.
e.
d.
c.
C
a.
4 PCS
4 PC
S
b.
4 PC
S
d.
4 PC
S
f.
4 PC
S
c.
4 PC
S
e.
1 PC
S
g.
1 PC
S
i.
2 PC
S
h.
18-
7/8
”
480 mm
anchor point
*
anchor point
*
anchor point*
wiring
22-
3/8
”
570 mm
6-
3/8
”
160 mm
3-
1/8
”
80 mm
6-
3/8
”
160 mm
Optional Installation Method
A. Attach tubing into desi
re
d positions on the towel warme
r.
B. Place towel warmer on the box (or a large sheet of paper)
and lay on a flat surface with brackets facing downwar
ds.
C. Mark the location of the following
:
• The electrical collar
• The location of the brackets
D.
Use the template as a guide to mark the wall with the
corr
ect locations of the four brackets, ensuring the following
:
• The electrical collar is lined up with the center of the
electrical box.
• At least two of the brackets ar
e lined up with a wall stud.
• The towel warmer is level.
Installation Support •(800) 875-5285 • www.WarmlyYours.com
SIERRA
INST
ALLA
TION MANUAL
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Operation:
Manual
You can operate your towel warmer by using the integrated on/of
f
switch that is located at the bottom of one of the towel warmer's
vertical stiles.
With a Contr
ol:
You may want to pair your towel warmer with a compatible
W
armlyY
ours timer or switch. Make sur
e to r
efer to the installation
manual of the contr
ol for pr
oper operation and installation. If you
have any questions, call 800-875-5285.
SAFETY INFORMA
TION
• T
owel W
armers ar
e designed to warm towels only and should
not be used for any other purpose.
• Never stand, sit on or hang on the T
owel W
armer unit
.
• Never allow childr
en to play on or with the T
owel W
armer
.
• Make sur
e that the electrical cir
cuit br
eaker is shut of
f at the
main panel befor
e wiring or servicing your T
owel W
armer
.
• The T
owel W
armer must be pr
operly gr
ounded.
• All wiring must be in accor
dance with the National Electrical Code
(NEC) and Canadian Electrical Code (CEC) and should be
performed by a licensed pr
ofessional who is certified to do
electr
cal wiring.
• Never place your T
owel W
armer inside a shower
, sauna or
steam r
oom.
• Never attempt to warm mor
e than two (2) towels on the
T
owel W
armer at a time. Overloading the T
owel W
armer will cause
the unit to become extr
emely hot and may r
esult in a bur
n if
touched.
• T
owel W
armers ar
e cETLus listed for use in US and
Candian markets.
CLEANING INFORMA
TION
Clean the T
owel W
armer with a soft, non-abrasive, damp cloth
while warm. Once the T
owel W
armer has cooled, lightly polish with
a soft dry cloth. Do not use abrasive cleaning powders, metal
polish or chlorine based cleaners on any part of the T
owel W
armer
.
INST
ALLA
TION
This appliance must be installed in accor
dance with the instruc-
tions in the manual and the NEC and CEC guidelines r
elating to
electrical fixtur
es in bathr
ooms. The T
owel W
armer must be on a
GFCI pr
otected cir
cuit and be wir
ed by a pr
ofessional who is
certified to do electrical wiring.
After installation is complete, connect the electric power and tur
n on the
Power Switch, located on the bottom left of the unit. The unit will begin to
heat. If the unit will not be used for an extended time, simply tur
n the unit
of
f using the power switch.
1. Do not hook the unit up to a cir
cuit until completely r
eading
these instructions.
2.
We
recommend mounting the left vertical rail mounts to a stud.
3. This pr
oduct is intended only for domestic use. Do not put the
unit into water
. Do not use in a sauna, shower cubicle or steam
room. This pr
oduct is for indoor use only
.
4. If the heating wir
e inside the unit fails or becomes damaged, tu
rn
the unit OFF and contact W
armlyY
ours. Do NOT attempt to r
epair
or r
emove the power switch or heating wir
e.
5. If you encounter any difficulties while installing your T
owel
W
armer
, installation support is available by phone, 24/7 at
(800) 875-5285.
5. If a
re
tu
rn
is necessary
, please use original packaging if possible.
SIERRA
INST
ALLA
TION MANUAL
SIERRA
INST
ALLA
TION MANUAL
Installation Support • No Nonsense™ Warranty • (800) 875-5285 • www.WarmlyYours.com
SIERRA
PA
RTS LIST
ITEM
PA
RT#
DESCRIPTION
QUANTITY
a.
0005-58120-0000
Tube standof
f, mounting, squar
e, stainless SM
4
b.
0005-51220-0000
Scr
ew
, set, M5/6, socket
4
c.
0005-58200-0001
Scr
ew
, hex, socket, 8x25mm
4
d.
0005-57500-0001
Anchor
, drywall
4
e.
0005-58120-0001
Bracket, wall mount
4
f.
0005-51200-0000
Scr
ew
, cr
oss, countersunk, 2*40
4
g.
0005-51820-0000
W
allplate, stainless, with gr
ommet and gr
ound
1
h.
0005-51200-0001
Scr
ew wallplate, stainless 6/32
2
i.
0005-58820-0000
Tube, stainless,
ro
und, electrical
1
j.
0005-51900-0000
Wr
ench, hex, 2.5
1
k.
0005-51900-0001
Wr
ench, hex, 6
1
n/a
AK05-58020-0000
Parts kit assembly
, SM
1
a.
b.
d.
f.
c.
e.
g.
j.
i.
h.
k.
SIERRA
INST
ALLA
TION MANUAL
BLACK OR BLUE
(HOT)
WHITE OR BROWN
(NEUTRAL
)
GREEN/YELLO
W
(GROUND)
2” x 4” ELECTRICAL
BOX FOR OPTIONAL
CONTROL
2” x 4” ELECTRICAL
BOX
TOWE
L
WA
RMER
HOT
LOAD
(BLACK OR BLUE)
LIN
E
(BLACK)
NEUTRAL
(WHITE)
LOAD
(BLUE)
GROUND
(GREEN/YELLOW)
120V OPTIONAL
CONTROL
NEUTRAL
LOAD
(WHITE OR BROWN)
ELECTRICAL
ROUGH-IN
3-W
AY
WIR
E
(YELLOW)
On
b.
A
A
B
B
C
d
e
f
g
h
A
B
C
g
h
2x4
Stud
TOOLS REQUIRED
INSTALLATION INSTRUCTIONS
- Review instructions carefully before installation
- Installation should be completed by a qualified person
- Please dispose of packaging in a resposible manner
1-2.
2-2.
1
2x4
Stud
2
a.
g.
i.
f.
e.
d.
c.
A
B
C
a.
4 PCS
4 PCS
b.
4 PCS
d.
4 PCS
f.
4 PCS
c.
4 PCS
e.
1 PCS
g.
1 PCS
i.
2 PCS
h.
18-
7/8
”
479 mm
anchor point*
anchor point*
wiring
22-
3/8
”
570 mm
6-
3/8
”
160 mm
3-
1/8
”
80 mm
6-
3/8
”
160 mm
Please peel
plastic film off of
electrical plate
Optional Installation Method
A. Attach tubing into desired positions on the towel warmer.
B. Place towel warmer on the box (or a large sheet of paper)
and lay on a flat surface with brackets facing downwards.
C. Mark the location of the following:
• The electrical collar
• The location of the brackets
D. Use the template as a guide to mark the wall with the
correct locations of the four brackets, ensuring the following:
• The electrical collar is lined up with the center of the
electrical box.
• At least two of the brackets are lined up with a wall stud.
• The towel warmer is level.
Installation Support •(800) 875-5285 • www.WarmlyYours.com
SIERRA INSTALLATION MANUAL
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Operation:
Manual
You can operate your towel warmer by using the integrated on/off
switch that is located at the bottom of one of the towel warmer's
vertical stiles.
With a Control:
You may want to pair your towel warmer with a compatible
WarmlyYours timer or switch. Make sure to refer to the installation
manual of the control for proper operation and installation. If you
have any questions, call 800-875-5285.
SAFETY INFORMATION
• Towel Warmers are designed to warm towels only and should
not be used for any other purpose.
• Never stand, sit on or hang on the Towel Warmer unit.
• Never allow children to play on or with the Towel Warmer.
• Make sure that the electrical circuit breaker is shut off at the
main panel before wiring or servicing your Towel Warmer.
• The Towel Warmer must be properly grounded.
• All wiring must be in accordance with the National Electrical Code
(NEC) and Canadian Electrical Code (CEC) and should be
performed by a licensed professional who is certified to do
electrcal wiring.
• Never place your Towel Warmer inside a shower, sauna or
steam room.
• Never attempt to warm more than two (2) towels on the
Towel Warmer at a time. Overloading the Towel Warmer will cause
the unit to become extremely hot and may result in a burn if
touched.
• Towel Warmers are cETLus listed for use in US and
Candian markets.
CLEANING INFORMATION
Clean the Towel Warmer with a soft, non-abrasive, damp cloth
while warm. Once the Towel Warmer has cooled, lightly polish with
a soft dry cloth. Do not use abrasive cleaning powders, metal
polish or chlorine based cleaners on any part of the Towel Warmer.
INSTALLATION
This appliance must be installed in accordance with the instruc-
tions in the manual and the NEC and CEC guidelines relating to
electrical fixtures in bathrooms. The Towel Warmer must be on a
GFCI protected circuit and be wired by a professional who is
certified to do electrical wiring.
After installation is complete, connect the electric power and turn on the
Power Switch, located on the bottom left of the unit. The unit will begin to
heat. If the unit will not be used for an extended time, simply turn the unit
off using the power switch.
1. Do not hook the unit up to a circuit until completely reading
these instructions.
2. We recommend mounting the left vertical rail mounts to a stud.
3. This product is intended only for domestic use. Do not put the
unit into water. Do not use in a sauna, shower cubicle or steam
room. This product is for indoor use only.
4. If the heating wire inside the unit fails or becomes damaged, turn
the unit OFF and contact WarmlyYours. Do NOT attempt to repair
or remove the power switch or heating wire.
5. If you encounter any difficulties while installing your Towel
Warmer, installation support is available by phone, 24/7 at
(800) 875-5285.
5. If a return is necessary, please use original packaging if possible.
SIERRA INSTALLATION MANUAL
SIERRA INSTALLATION MANUAL
Installation Support • No Nonsense™ Warranty • (800) 875-5285 • www.WarmlyYours.com
SIERRA PARTS LIST
ITEM
PART#
DESCRIPTION
QUANTITY
a.
0005-58120-0000
Tube standoff, mounting, square, stainless SM
4
b.
0005-51220-0000
Screw, set, M5/6, socket
4
c.
0005-58200-0001
Screw, hex, socket, 8x25mm
4
d.
0005-57500-0001
Anchor, drywall
4
e.
0005-58120-0001
Bracket, wall mount
4
f.
0005-51200-0000
Screw, cross, countersunk, 2*40
4
g.
0005-51820-0000
Wallplate, stainless, with grommet and ground
1
h.
0005-51200-0001
Screw wallplate, stainless 6/32
2
i.
0005-58820-0000
Tube, stainless, round, electrical
1
j.
0005-51900-0000
Wrench, hex, 2.5
1
k.
0005-51900-0001
Wrench, hex, 6
1
n/a
AK05-58020-0000
Parts kit assembly, SM
1
a.
b.
d.
f.
c.
e.
g.
j.
i.
h.
k.
SIERRA INSTALLATION MANUAL
BLACK OR BLUE
(HOT)
WHITE OR BROWN
(NEUTRAL)
GREEN/YELLOW
(GROUND)
2” x 4” ELECTRICAL
BOX FOR OPTIONAL CONTROL
2” x 4” ELECTRICAL BOX
TOWEL WARMER
HOT LOAD
(BLACK OR BLUE)
LINE
(BLACK)
NEUTRAL
(WHITE)
LOAD
(BLUE)
GROUND
(GREEN/YELLOW)
120V OPTIONAL CONTROL
NEUTRAL LOAD
(WHITE OR BROWN)
ELECTRICAL ROUGH-IN
3-WAY WIRE
(YELLOW)
On
b.
2x4
Stud
TOOLS REQUIRED
INSTALLATION INSTRUCTIONS
- Review instructions carefully before installation
- Installation should be completed by a qualified person
- Please dispose of packaging in a resposible manner
1-2.
2-2.
1
2x4
Stud
2
a.
g.
i.
f.
e.
d.
c.
A
B
C
a.
4 PCS
4 PCS
b.
4 PCS
d.
4 PCS
f.
4 PCS
c.
4 PCS
e.
1 PCS
g.
1 PCS
i.
2 PCS
h.
18-
7/8
”
479 mm
anchor point*
anchor point*
wiring
22-
3/8
”
570 mm
6-
3/8
”
160 mm
3-
1/8
”
80 mm
6-
3/8
”
160 mm
Please peel
plastic film off of
electrical plate
Optional Installation Method
A. Attach tubing into desired positions on the towel warmer.
B. Place towel warmer on the box (or a large sheet of paper)
and lay on a flat surface with brackets facing downwards.
C. Mark the location of the following:
• The electrical collar
• The location of the brackets
D. Use the template as a guide to mark the wall with the
correct locations of the four brackets, ensuring the following:
• The electrical collar is lined up with the center of the
electrical box.
• At least two of the brackets are lined up with a wall stud.
• The towel warmer is level.
Installation Support •(800) 875-5285 • www.WarmlyYours.com
SIERRA INSTALLATION MANUAL
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Operation:
Manual
You can operate your towel warmer by using the integrated on/off
switch that is located at the bottom of one of the towel warmer's
vertical stiles.
With a Control:
You may want to pair your towel warmer with a compatible
WarmlyYours timer or switch. Make sure to refer to the installation
manual of the control for proper operation and installation. If you
have any questions, call 800-875-5285.
SAFETY INFORMATION
• Towel Warmers are designed to warm towels only and should
not be used for any other purpose.
• Never stand, sit on or hang on the Towel Warmer unit.
• Never allow children to play on or with the Towel Warmer.
• Make sure that the electrical circuit breaker is shut off at the
main panel before wiring or servicing your Towel Warmer.
• The Towel Warmer must be properly grounded.
• All wiring must be in accordance with the National Electrical Code
(NEC) and Canadian Electrical Code (CEC) and should be
performed by a licensed professional who is certified to do
electrcal wiring.
• Never place your Towel Warmer inside a shower, sauna or
steam room.
• Never attempt to warm more than two (2) towels on the
Towel Warmer at a time. Overloading the Towel Warmer will cause
the unit to become extremely hot and may result in a burn if
touched.
• Towel Warmers are cETLus listed for use in US and
Candian markets.
CLEANING INFORMATION
Clean the Towel Warmer with a soft, non-abrasive, damp cloth
while warm. Once the Towel Warmer has cooled, lightly polish with
a soft dry cloth. Do not use abrasive cleaning powders, metal
polish or chlorine based cleaners on any part of the Towel Warmer.
INSTALLATION
This appliance must be installed in accordance with the instruc-
tions in the manual and the NEC and CEC guidelines relating to
electrical fixtures in bathrooms. The Towel Warmer must be on a
GFCI protected circuit and be wired by a professional who is
certified to do electrical wiring.
After installation is complete, connect the electric power and turn on the
Power Switch, located on the bottom left of the unit. The unit will begin to
heat. If the unit will not be used for an extended time, simply turn the unit
off using the power switch.
1. Do not hook the unit up to a circuit until completely reading
these instructions.
2. We recommend mounting the left vertical rail mounts to a stud.
3. This product is intended only for domestic use. Do not put the
unit into water. Do not use in a sauna, shower cubicle or steam
room. This product is for indoor use only.
4. If the heating wire inside the unit fails or becomes damaged, turn
the unit OFF and contact WarmlyYours. Do NOT attempt to repair
or remove the power switch or heating wire.
5. If you encounter any difficulties while installing your Towel
Warmer, installation support is available by phone, 24/7 at
(800) 875-5285.
5. If a return is necessary, please use original packaging if possible.
SIERRA INSTALLATION MANUAL
SIERRA INSTALLATION MANUAL
Installation Support • No Nonsense™ Warranty • (800) 875-5285 • www.WarmlyYours.com
SIERRA PARTS LIST
ITEM
PART#
DESCRIPTION
QUANTITY
a.
0005-58120-0000
Tube standoff, mounting, square, stainless SM
4
b.
0005-51220-0000
Screw, set, M5/6, socket
4
c.
0005-58200-0001
Screw, hex, socket, 8x25mm
4
d.
0005-57500-0001
Anchor, drywall
4
e.
0005-58120-0001
Bracket, wall mount
4
f.
0005-51200-0000
Screw, cross, countersunk, 2*40
4
g.
0005-51820-0000
Wallplate, stainless, with grommet and ground
1
h.
0005-51200-0001
Screw wallplate, stainless 6/32
2
i.
0005-58820-0000
Tube, stainless, round, electrical
1
j.
0005-51900-0000
Wrench, hex, 2.5
1
k.
0005-51900-0001
Wrench, hex, 6
1
n/a
AK05-58020-0000
Parts kit assembly, SM
1
a.
b.
d.
f.
c.
e.
g.
j.
i.
h.
k.
SIERRA INSTALLATION MANUAL
BLACK OR BLUE
(HOT)
WHITE OR BROWN
(NEUTRAL)
GREEN/YELLOW
(GROUND)
2” x 4” ELECTRICAL
BOX FOR OPTIONAL CONTROL
2” x 4” ELECTRICAL BOX
TOWEL WARMER
HOT LOAD
(BLACK OR BLUE)
LINE
(BLACK)
NEUTRAL
(WHITE)
LOAD
(BLUE)
GROUND
(GREEN/YELLOW)
120V OPTIONAL CONTROL
NEUTRAL LOAD
(WHITE OR BROWN)
ELECTRICAL ROUGH-IN
3-WAY WIRE
(YELLOW)
On
b.
2x4 Stu
d
TOOLS REQUIRED
INST
ALLA
TION INSTR
UCTIONS
- Review instructions car
efully befor
e installation
- Installation should be completed by a qualified person - Please dispose of packaging in a r
esposible manner
1-2.
2-2.
1
2x4 Stud
2
a.
g.
i.
f.
e.
d.
c.
A
B
C
a.
4 PCS
4 PC
S
b.
4 PC
S
d.
4 PC
S
f.
4 PC
S
c.
4 PC
S
e.
1 PC
S
g.
1 PC
S
i.
2 PC
S
h.
18-
7/8
”
479 mm
anchor point
*
anchor point
*
wiring
22-
3/8
”
570 mm
6-
3/8
”
160 mm
3-
1/8
”
80 mm
6-
3/8
”
160 mm
Please peel plastic film of
f of
electrical plate
Optional Installation Method
A. Attach tubing into desi
re
d positions on the towel warme
r.
B. Place towel warmer on the box (or a large sheet of paper) and lay on a flat surface with brackets facing downwar
ds.
C. Mark the location of the following
:
• The electrical collar • The location of the brackets
D.
Use the template as a guide to mark the wall with the
corr
ect locations of the four brackets, ensuring the following
:
• The electrical collar is lined up with the center of the electrical box. • At least two of the brackets ar
e lined up with a wall stud.
• The towel warmer is level.
Installation Support •(800) 875-5285 • www.WarmlyYours.com
SIERRA
INST
ALLA
TION MANUAL
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Operation:
Manual You can operate your towel warmer by using the integrated on/of
f
switch that is located at the bottom of one of the towel warmer's vertical stiles.
With a Contr
ol:
You may want to pair your towel warmer with a compatible W
armlyY
ours timer or switch. Make sur
e to r
efer to the installation
manual of the contr
ol for pr
oper operation and installation. If you
have any questions, call 800-875-5285.
SAFETY INFORMA
TION
• T
owel W
armers ar
e designed to warm towels only and should
not be used for any other purpose. • Never stand, sit on or hang on the T
owel W
armer unit
.
• Never allow childr
en to play on or with the T
owel W
armer
.
• Make sur
e that the electrical cir
cuit br
eaker is shut of
f at the
main panel befor
e wiring or servicing your T
owel W
armer
.
• The T
owel W
armer must be pr
operly gr
ounded.
• All wiring must be in accor
dance with the National Electrical Code
(NEC) and Canadian Electrical Code (CEC) and should be performed by a licensed pr
ofessional who is certified to do
electr
cal wiring.
• Never place your T
owel W
armer inside a shower
, sauna or
steam r
oom.
• Never attempt to warm mor
e than two (2) towels on the
T
owel W
armer at a time. Overloading the T
owel W
armer will cause
the unit to become extr
emely hot and may r
esult in a bur
n if
touched. • T
owel W
armers ar
e cETLus listed for use in US and
Candian markets.
CLEANING INFORMA
TION
Clean the T
owel W
armer with a soft, non-abrasive, damp cloth
while warm. Once the T
owel W
armer has cooled, lightly polish with
a soft dry cloth. Do not use abrasive cleaning powders, metal polish or chlorine based cleaners on any part of the T
owel W
armer
.
INST
ALLA
TION
This appliance must be installed in accor
dance with the instruc-
tions in the manual and the NEC and CEC guidelines r
elating to
electrical fixtur
es in bathr
ooms. The T
owel W
armer must be on a
GFCI pr
otected cir
cuit and be wir
ed by a pr
ofessional who is
certified to do electrical wiring.
After installation is complete, connect the electric power and tur
n on the
Power Switch, located on the bottom left of the unit. The unit will begin to heat. If the unit will not be used for an extended time, simply tur
n the unit
of
f using the power switch.
1. Do not hook the unit up to a cir
cuit until completely r
eading
these instructions.
2.
We
recommend mounting the left vertical rail mounts to a stud.
3. This pr
oduct is intended only for domestic use. Do not put the
unit into water
. Do not use in a sauna, shower cubicle or steam
room. This pr
oduct is for indoor use only
.
4. If the heating wir
e inside the unit fails or becomes damaged, tu
rn
the unit OFF and contact W
armlyY
ours. Do NOT attempt to r
epair
or r
emove the power switch or heating wir
e.
5. If you encounter any difficulties while installing your T
owel
W
armer
, installation support is available by phone, 24/7 at
(800) 875-5285.
5. If a
re
tu
rn
is necessary
, please use original packaging if possible.
SIERRA
INST
ALLA
TION MANUAL
SIERRA
INST
ALLA
TION MANUAL
Installation Support • No Nonsense™ Warranty • (800) 875-5285 • www.WarmlyYours.com
SIERRA
PA
R
TS LIST
ITEM
PA
R
T#
DESCRIPTION
QUANTITY
a.
0005-58120-0000
Tube standof
f, mounting, squar
e, stainless SM
4
b.
0005-51220-0000
Scr
ew
, set, M5/6, socket
4
c.
0005-58200-0001
Scr
ew
, hex, socket, 8x25mm
4
d.
0005-57500-0001
Anchor
, drywall
4
e.
0005-58120-0001
Bracket, wall mount
4
f.
0005-51200-0000
Scr
ew
, cr
oss, countersunk, 2*40
4
g.
0005-51820-0000
W
allplate, stainless, with gr
ommet and gr
ound
1
h.
0005-51200-0001
Scr
ew wallplate, stainless 6/32
2
i.
0005-58820-0000
Tube, stainless,
ro
und, electrical
1
j.
0005-51900-0000
Wr
ench, hex, 2.5
1
k.
0005-51900-0001
Wr
ench, hex, 6
1
n/a
AK05-58020-0000
Parts kit assembly
, SM
1
a.
b.
d.
f.
c.
e.
g.
j.
i.
h.
k.
SIERRA
INST
ALLA
TION MANUAL
BLACK OR BLUE (HOT)
WHITE OR BROWN (NEUTRAL
)
GREEN/YELLO
W
(GROUND)
2” x 4” ELECTRICAL
BOX FOR OPTIONAL
CONTROL
2” x 4” ELECTRICAL
BOX
TOWE
L
WA
RMER
HOT
LOAD
(BLACK OR BLUE)
LIN
E
(BLACK)
NEUTRAL (WHITE)
LOAD (BLUE)
GROUND (GREEN/YELLOW)
120V OPTIONAL
CONTROL
NEUTRAL
LOAD
(WHITE OR BROWN)
ELECTRICAL
ROUGH-IN
3-W
AY
WIR
E
(YELLOW)
On
b.
2x4 Stu
d
TOOLS REQUIRED
INST
ALLA
TION INSTR
UCTIONS
- Review instructions car
efully befor
e installation
- Installation should be completed by a qualified person - Please dispose of packaging in a r
esposible manner
1-2.
2-2.
1
2x4 Stud
2
a.
g.
i.
f.
e.
d.
c.
A
B
C
a.
4 PCS
4 PC
S
b.
4 PC
S
d.
4 PC
S
f.
4 PC
S
c.
4 PC
S
e.
1 PC
S
g.
1 PC
S
i.
2 PC
S
h.
18-
7/8
”
479 mm
anchor point
*
anchor point
*
wiring
22-
3/8
”
570 mm
6-
3/8
”
160 mm
3-
1/8
”
80 mm
6-
3/8
”
160 mm
Please peel plastic film of
f of
electrical plate
Optional Installation Method
A. Attach tubing into desi
re
d positions on the towel warme
r.
B. Place towel warmer on the box (or a large sheet of paper) and lay on a flat surface with brackets facing downwar
ds.
C. Mark the location of the following
:
• The electrical collar • The location of the brackets
D.
Use the template as a guide to mark the wall with the
corr
ect locations of the four brackets, ensuring the following
:
• The electrical collar is lined up with the center of the electrical box. • At least two of the brackets ar
e lined up with a wall stud.
• The towel warmer is level.
Installation Support •(800) 875-5285 • www.WarmlyYours.com
SIERRA
INST
ALLA
TION MANUAL
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Operation:
Manual You can operate your towel warmer by using the integrated on/of
f
switch that is located at the bottom of one of the towel warmer's vertical stiles.
With a Contr
ol:
You may want to pair your towel warmer with a compatible W
armlyY
ours timer or switch. Make sur
e to r
efer to the installation
manual of the contr
ol for pr
oper operation and installation. If you
have any questions, call 800-875-5285.
SAFETY INFORMA
TION
• T
owel W
armers ar
e designed to warm towels only and should
not be used for any other purpose. • Never stand, sit on or hang on the T
owel W
armer unit
.
• Never allow childr
en to play on or with the T
owel W
armer
.
• Make sur
e that the electrical cir
cuit br
eaker is shut of
f at the
main panel befor
e wiring or servicing your T
owel W
armer
.
• The T
owel W
armer must be pr
operly gr
ounded.
• All wiring must be in accor
dance with the National Electrical Code
(NEC) and Canadian Electrical Code (CEC) and should be performed by a licensed pr
ofessional who is certified to do
electr
cal wiring.
• Never place your T
owel W
armer inside a shower
, sauna or
steam r
oom.
• Never attempt to warm mor
e than two (2) towels on the
T
owel W
armer at a time. Overloading the T
owel W
armer will cause
the unit to become extr
emely hot and may r
esult in a bur
n if
touched. • T
owel W
armers ar
e cETLus listed for use in US and
Candian markets.
CLEANING INFORMA
TION
Clean the T
owel W
armer with a soft, non-abrasive, damp cloth
while warm. Once the T
owel W
armer has cooled, lightly polish with
a soft dry cloth. Do not use abrasive cleaning powders, metal polish or chlorine based cleaners on any part of the T
owel W
armer
.
INST
ALLA
TION
This appliance must be installed in accor
dance with the instruc-
tions in the manual and the NEC and CEC guidelines r
elating to
electrical fixtur
es in bathr
ooms. The T
owel W
armer must be on a
GFCI pr
otected cir
cuit and be wir
ed by a pr
ofessional who is
certified to do electrical wiring.
After installation is complete, connect the electric power and tur
n on the
Power Switch, located on the bottom left of the unit. The unit will begin to heat. If the unit will not be used for an extended time, simply tur
n the unit
of
f using the power switch.
1. Do not hook the unit up to a cir
cuit until completely r
eading
these instructions.
2.
We
recommend mounting the left vertical rail mounts to a stud.
3. This pr
oduct is intended only for domestic use. Do not put the
unit into water
. Do not use in a sauna, shower cubicle or steam
room. This pr
oduct is for indoor use only
.
4. If the heating wir
e inside the unit fails or becomes damaged, tu
rn
the unit OFF and contact W
armlyY
ours. Do NOT attempt to r
epair
or r
emove the power switch or heating wir
e.
5. If you encounter any difficulties while installing your T
owel
W
armer
, installation support is available by phone, 24/7 at
(800) 875-5285.
5. If a
re
tu
rn
is necessary
, please use original packaging if possible.
SIERRA
INST
ALLA
TION MANUAL
SIERRA
INST
ALLA
TION MANUAL
Installation Support • No Nonsense™ Warranty • (800) 875-5285 • www.WarmlyYours.com
SIERRA
PA
R
TS LIST
ITEM
PA
R
T#
DESCRIPTION
QUANTITY
a.
0005-58120-0000
Tube standof
f, mounting, squar
e, stainless SM
4
b.
0005-51220-0000
Scr
ew
, set, M5/6, socket
4
c.
0005-58200-0001
Scr
ew
, hex, socket, 8x25mm
4
d.
0005-57500-0001
Anchor
, drywall
4
e.
0005-58120-0001
Bracket, wall mount
4
f.
0005-51200-0000
Scr
ew
, cr
oss, countersunk, 2*40
4
g.
0005-51820-0000
W
allplate, stainless, with gr
ommet and gr
ound
1
h.
0005-51200-0001
Scr
ew wallplate, stainless 6/32
2
i.
0005-58820-0000
Tube, stainless,
ro
und, electrical
1
j.
0005-51900-0000
Wr
ench, hex, 2.5
1
k.
0005-51900-0001
Wr
ench, hex, 6
1
n/a
AK05-58020-0000
Parts kit assembly
, SM
1
a.
b.
d.
f.
c.
e.
g.
j.
i.
h.
k.
SIERRA
INST
ALLA
TION MANUAL
BLACK OR BLUE (HOT)
WHITE OR BROWN (NEUTRAL
)
GREEN/YELLO
W
(GROUND)
2” x 4” ELECTRICAL
BOX FOR OPTIONAL
CONTROL
2” x 4” ELECTRICAL
BOX
TOWE
L
WA
RMER
HOT
LOAD
(BLACK OR BLUE)
LIN
E
(BLACK)
NEUTRAL (WHITE)
LOAD (BLUE)
GROUND (GREEN/YELLOW)
120V OPTIONAL
CONTROL
NEUTRAL
LOAD
(WHITE OR BROWN)
ELECTRICAL
ROUGH-IN
3-W
AY
WIR
E
(YELLOW)
On
b.
2x4
Stud
TOOLS REQUIRED
INSTALLATION INSTRUCTIONS
- Review instructions carefully before installation
- Installation should be completed by a qualified person
- Please dispose of packaging in a resposible manner
1-2.
2-2.
1
2x4
Stud
2
a.
g.
i.
f.
e.
d.
c.
A
B
C
a.
4 PCS
4 PCS
b.
4 PCS
d.
4 PCS
f.
4 PCS
c.
4 PCS
e.
1 PCS
g.
1 PCS
i.
2 PCS
h.
18-
7/8
”
479 mm
anchor point*
anchor point*
wiring
22-
3/8
”
570 mm
6-
3/8
”
160 mm
3-
1/8
”
80 mm
6-
3/8
”
160 mm
Please peel
plastic film off of
electrical plate
Optional Installation Method
A. Attach tubing into desired positions on the towel warmer.
B. Place towel warmer on the box (or a large sheet of paper)
and lay on a flat surface with brackets facing downwards.
C. Mark the location of the following:
• The electrical collar
• The location of the brackets
D. Use the template as a guide to mark the wall with the
correct locations of the four brackets, ensuring the following:
• The electrical collar is lined up with the center of the
electrical box.
• At least two of the brackets are lined up with a wall stud.
• The towel warmer is level.
Installation Support •(800) 875-5285 • www.WarmlyYours.com
SIERRA INSTALLATION MANUAL
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Operation:
Manual
You can operate your towel warmer by using the integrated on/off
switch that is located at the bottom of one of the towel warmer's
vertical stiles.
With a Control:
You may want to pair your towel warmer with a compatible
WarmlyYours timer or switch. Make sure to refer to the installation
manual of the control for proper operation and installation. If you
have any questions, call 800-875-5285.
SAFETY INFORMATION
• Towel Warmers are designed to warm towels only and should
not be used for any other purpose.
• Never stand, sit on or hang on the Towel Warmer unit.
• Never allow children to play on or with the Towel Warmer.
• Make sure that the electrical circuit breaker is shut off at the
main panel before wiring or servicing your Towel Warmer.
• The Towel Warmer must be properly grounded.
• All wiring must be in accordance with the National Electrical Code
(NEC) and Canadian Electrical Code (CEC) and should be
performed by a licensed professional who is certified to do
electrcal wiring.
• Never place your Towel Warmer inside a shower, sauna or
steam room.
• Never attempt to warm more than two (2) towels on the
Towel Warmer at a time. Overloading the Towel Warmer will cause
the unit to become extremely hot and may result in a burn if
touched.
• Towel Warmers are cETLus listed for use in US and
Candian markets.
CLEANING INFORMATION
Clean the Towel Warmer with a soft, non-abrasive, damp cloth
while warm. Once the Towel Warmer has cooled, lightly polish with
a soft dry cloth. Do not use abrasive cleaning powders, metal
polish or chlorine based cleaners on any part of the Towel Warmer.
INSTALLATION
This appliance must be installed in accordance with the instruc-
tions in the manual and the NEC and CEC guidelines relating to
electrical fixtures in bathrooms. The Towel Warmer must be on a
GFCI protected circuit and be wired by a professional who is
certified to do electrical wiring.
After installation is complete, connect the electric power and turn on the
Power Switch, located on the bottom left of the unit. The unit will begin to
heat. If the unit will not be used for an extended time, simply turn the unit
off using the power switch.
1. Do not hook the unit up to a circuit until completely reading
these instructions.
2. We recommend mounting the left vertical rail mounts to a stud.
3. This product is intended only for domestic use. Do not put the
unit into water. Do not use in a sauna, shower cubicle or steam
room. This product is for indoor use only.
4. If the heating wire inside the unit fails or becomes damaged, turn
the unit OFF and contact WarmlyYours. Do NOT attempt to repair
or remove the power switch or heating wire.
5. If you encounter any difficulties while installing your Towel
Warmer, installation support is available by phone, 24/7 at
(800) 875-5285.
5. If a return is necessary, please use original packaging if possible.
SIERRA INSTALLATION MANUAL
SIERRA INSTALLATION MANUAL
Installation Support • No Nonsense™ Warranty • (800) 875-5285 • www.WarmlyYours.com
SIERRA PARTS LIST
ITEM
PART#
DESCRIPTION
QUANTITY
a.
0005-58120-0000
Tube standoff, mounting, square, stainless SM
4
b.
0005-51220-0000
Screw, set, M5/6, socket
4
c.
0005-58200-0001
Screw, hex, socket, 8x25mm
4
d.
0005-57500-0001
Anchor, drywall
4
e.
0005-58120-0001
Bracket, wall mount
4
f.
0005-51200-0000
Screw, cross, countersunk, 2*40
4
g.
0005-51820-0000
Wallplate, stainless, with grommet and ground
1
h.
0005-51200-0001
Screw wallplate, stainless 6/32
2
i.
0005-58820-0000
Tube, stainless, round, electrical
1
j.
0005-51900-0000
Wrench, hex, 2.5
1
k.
0005-51900-0001
Wrench, hex, 6
1
n/a
AK05-58020-0000
Parts kit assembly, SM
1
a.
b.
d.
f.
c.
e.
g.
j.
i.
h.
k.
SIERRA INSTALLATION MANUAL
BLACK OR BLUE
(HOT)
WHITE OR BROWN
(NEUTRAL)
GREEN/YELLOW
(GROUND)
2” x 4” ELECTRICAL
BOX FOR OPTIONAL CONTROL
2” x 4” ELECTRICAL BOX
TOWEL WARMER
HOT LOAD
(BLACK OR BLUE)
LINE
(BLACK)
NEUTRAL
(WHITE)
LOAD
(BLUE)
GROUND
(GREEN/YELLOW)
120V OPTIONAL CONTROL
NEUTRAL LOAD
(WHITE OR BROWN)
ELECTRICAL ROUGH-IN
3-WAY WIRE
(YELLOW)
On
b.
Sierra Power Leg
Part Number
Description
Quantity Partslist ID
0005-58120-0005
Leg, Mounting, Polished, Square
3
A
0005-58170-0000
Leg, Mounting, Gold, Square
3
A
0005-58180-0002
Leg, Mounting, Black, Square
3
A
0005-58300-0000
Screw, Leg to Rail, M8x20, Socket
3
B
0005-58110-0000
Bracket, Round, Mounting, Full
3
C
0005-58200-0001
Screw, Set, Allen, Socket, M5*6
4
D
0005-58200-0002
Screw, Set, Allen, Socket, M5*6, Power Leg
1
E
0005-58500-0000
Anchor, Wall
4
F
0005-58200-0001
Screw, Bracket Mounting, ST4.2*40, Phillips,
4
G
0005-58110-0000
Bracket, Mounting, Power Leg, 3/4 size
1
H
0005-51900-0001
Wrench, Hex, 6mm
1
I
0005-58120-0007
Collar, Leg, Polished, Square
4
J
0005-58170-0001
Collar, Leg, Gold, Square
4
J
0005-58180-0003
Collar, Leg, Black, Square
4
J
0005-58790-0000
Plug, Plastic, Power Leg
1
K
0005-51900-0000
Wrench, Hex, 2.5mm
1
L
0005-58120-0006
Leg, Mounting, Power, Polished, Square
1
M
0005-58170-0002
Leg, Mounting, Power, Gold, Square
1
M
0005-58180-0004
Leg, Mounting, Power, Black, Square
1
M
AK05-58020-0003
Parts Kit, Sierra, Metropolitan, Power Leg, Polished
1
N/S
AK05-58070-0000
Parts Kit, Sierra, Metropolitan, Power Leg, Gold
1
N/S
AK05-58080-0001
Parts Kit, Sierra, Metropolitan, Power Leg, Black
1
N/S
2x4
Stud
TOOLS REQUIRED
INSTALLATION INSTRUCTIONS
- Review instructions carefully before installation
- Installation should be completed by a qualified person
- Please dispose of packaging in a resposible manner
1-2.
2-2.
1
2x4
Stud
2
a.
g.
f.
e.
d.
c.
C
a.
4 PCS
4 PCS
b.
4 PCS
d.
4 PCS
f.
4 PCS
c.
4 PCS
e.
1 PCS
g.
1 PCS
i.
2 PCS
h.
18-
7/8
”
480 mm
anchor point*
anchor point*
anchor point*
wiring
22-
3/8
”
570 mm
6-
3/8
”
160 mm
3-
1/8
”
80 mm
6-
3/8
”
160 mm
Optional Installation Method
A. Attach tubing into desired positions on the towel warmer.
B. Place towel warmer on the box (or a large sheet of paper)
and lay on a flat surface with brackets facing downwards.
C. Mark the location of the following:
• The electrical collar
• The location of the brackets
D. Use the template as a guide to mark the wall with the
correct locations of the four brackets, ensuring the following:
• The electrical collar is lined up with the center of the
electrical box.
• At least two of the brackets are lined up with a wall stud.
• The towel warmer is level.
Installation Support •(800) 875-5285 • www.WarmlyYours.com
SIERRA INSTALLATION MANUAL
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Operation:
Manual
You can operate your towel warmer by using the integrated on/off
switch that is located at the bottom of one of the towel warmer's
vertical stiles.
With a Control:
You may want to pair your towel warmer with a compatible
WarmlyYours timer or switch. Make sure to refer to the installation
manual of the control for proper operation and installation. If you
have any questions, call 800-875-5285.
SAFETY INFORMATION
• Towel Warmers are designed to warm towels only and should
not be used for any other purpose.
• Never stand, sit on or hang on the Towel Warmer unit.
• Never allow children to play on or with the Towel Warmer.
• Make sure that the electrical circuit breaker is shut off at the
main panel before wiring or servicing your Towel Warmer.
• The Towel Warmer must be properly grounded.
• All wiring must be in accordance with the National Electrical Code
(NEC) and Canadian Electrical Code (CEC) and should be
performed by a licensed professional who is certified to do
electrcal wiring.
• Never place your Towel Warmer inside a shower, sauna or
steam room.
• Never attempt to warm more than two (2) towels on the
Towel Warmer at a time. Overloading the Towel Warmer will cause
the unit to become extremely hot and may result in a burn if
touched.
• Towel Warmers are cETLus listed for use in US and
Candian markets.
CLEANING INFORMATION
Clean the Towel Warmer with a soft, non-abrasive, damp cloth
while warm. Once the Towel Warmer has cooled, lightly polish with
a soft dry cloth. Do not use abrasive cleaning powders, metal
polish or chlorine based cleaners on any part of the Towel Warmer.
INSTALLATION
This appliance must be installed in accordance with the instruc-
tions in the manual and the NEC and CEC guidelines relating to
electrical fixtures in bathrooms. The Towel Warmer must be on a
GFCI protected circuit and be wired by a professional who is
certified to do electrical wiring.
After installation is complete, connect the electric power and turn on the
Power Switch, located on the bottom left of the unit. The unit will begin to
heat. If the unit will not be used for an extended time, simply turn the unit
off using the power switch.
1. Do not hook the unit up to a circuit until completely reading
these instructions.
2. We recommend mounting the left vertical rail mounts to a stud.
3. This product is intended only for domestic use. Do not put the
unit into water. Do not use in a sauna, shower cubicle or steam
room. This product is for indoor use only.
4. If the heating wire inside the unit fails or becomes damaged, turn
the unit OFF and contact WarmlyYours. Do NOT attempt to repair
or remove the power switch or heating wire.
5. If you encounter any difficulties while installing your Towel
Warmer, installation support is available by phone, 24/7 at
(800) 875-5285.
5. If a return is necessary, please use original packaging if possible.
SIERRA INSTALLATION MANUAL
SIERRA INSTALLATION MANUAL
Installation Support • No Nonsense™ Warranty • (800) 875-5285 • www.WarmlyYours.com
SIERRA PARTS LIST
ITEM
PART#
DESCRIPTION
QUANTITY
a.
0005-58120-0000
Tube standoff, mounting, square, stainless SM
4
b.
0005-51220-0000
Screw, set, M5/6, socket
4
c.
0005-58200-0001
Screw, hex, socket, 8x25mm
4
d.
0005-57500-0001
Anchor, drywall
4
e.
0005-58120-0001
Bracket, wall mount
4
f.
0005-51200-0000
Screw, cross, countersunk, 2*40
4
g.
0005-51820-0000
Wallplate, stainless, with grommet and ground
1
h.
0005-51200-0001
Screw wallplate, stainless 6/32
2
i.
0005-58820-0000
Tube, stainless, round, electrical
1
j.
0005-51900-0000
Wrench, hex, 2.5
1
k.
0005-51900-0001
Wrench, hex, 6
1
n/a
AK05-58020-0000
Parts kit assembly, SM
1
a.
b.
d.
f.
c.
e.
g.
j.
i.
h.
k.
SIERRA INSTALLATION MANUAL
BLACK OR BLUE
(HOT)
WHITE OR BROWN
(NEUTRAL)
GREEN/YELLOW
(GROUND)
2” x 4” ELECTRICAL
BOX FOR OPTIONAL CONTROL
2” x 4” ELECTRICAL BOX
TOWEL WARMER
HOT LOAD
(BLACK OR BLUE)
LINE
(BLACK)
NEUTRAL
(WHITE)
LOAD
(BLUE)
GROUND
(GREEN/YELLOW)
120V OPTIONAL CONTROL
NEUTRAL LOAD
(WHITE OR BROWN)
ELECTRICAL ROUGH-IN
3-WAY WIRE
(YELLOW)
On
b.
C
I
L
F
G
J
A
B
M
H
K
Power Leg
Plug
E
D
A1
tools
required
Ø8mm
H
L
3PCS
1-3
- installation
should
be
completed
by
a suitably
qualified
person
- please
dispose
of packaging
in a
responsible
manner
Installation instruction
- Review instructions carefully before installation
4PCS
4PCS
4PCS
3PCS
3PCS
E68 Radiator Installation Instruction
1
Ø8mm
2
1PCS
1PCS
1PCS
1PCS
1PCS
A2
a
b
c
d
e
f
g
h
i
j
k
a
c
d
k
f
e
h
g
4PCS
l