Page1
Advanced settings
To enter the advanced settings, you need to press button to turn off the thermostat. Then press and hold for about 5 seconds until menu 01
is shown on screen. Press to select menu number, and press or to adjust the settings for each menu. Below are examples and menu list.
Auto / Manual mode
Press to select between Auto and Manual mode. In manual mode, the thermostat maintains a constant set temperature manually set by the user. In Auto
mode, the thermostat follows the programmed schedule.
Installation Manual
Sensor Selection
A = Air sensing using built in sensor
F = Floor sensing using remote floor temperature
AF = Air sensing for setpoint, floor sensing for safety cut off
Menu #
Menu 01
01
Programming Option - 2 options for time/temperature settings
5_2 = 5 days (Mon - Fri) with same time/temperature settings and 2 days (Sat - Sun) with
same time/temperature settings
7_0 = 7 days allow for individual day settings or whole week settings
Floor Temperature Limit - Provides floor temperature protection when using AF function
12/24 Hour clock
Select backlight function
Thermostat Calibration (FLOOR) - By adjusting this figure any discrepancy between
displayed floor temperature and measured floor temperature can be compensated for
Switching differential - The number of degrees difference between switching off at the
set temperature and on again to reach the set temperature i.e. A 1°C setting will switch
the thermostat on 0.5 °C below the setpoint and switch it off 0.5 °C above the setpoint
30 seconds
10,20,30......60 ,ON
12 / 24
Thermostat Calibration (AIR) - By adjusting this figure any discrepancy between
displayed air temperature and measured air room temperature can be compensated for
02
03
04
05
06
07
08
09
10
11
Feature Description
Factory Default
Options
0 °C
5_2
5_2 / 7_0
40 °C
20°C ~ 90 °C
24
OFF
OFF / ON
A / F / AF
A / F / AF
A
A
Press or to select
Frost protection - Set to ON to maintain a room temperature above 5°C in the event of
severe low temperatures
1°C
1°C ~ 5°C
-5°C ~ +5°C
0°C
-5°C ~ +5°C
Power
Up/Down
Day of the week
Periods
key lock
AUTO
Anti-frozen
FLOOR
Clock setting
WHT 1000 Thermostat
Explanation of Symbols
Manual Mode
Auto Mode
Heating On
Room Temperature
Floor Temperature
Time
Menu
WiFi symbol
If menu 01 is set to AF. Use menu 05 to choose to show air temperature, floor temperature
This allows users to select between °C or °F.
°C
°C / °F
or to show both floor & air in interval.
option
thermostat is
turned off
Menu 02
option