background image

Page1

Advanced settings

To enter the advanced settings,  you need to press              button to turn off the thermostat.  Then press and hold           for about 5 seconds until  menu 01
is shown on screen.  Press             to select menu number, and press              or          to adjust the settings for each menu. Below are examples and menu list.

Auto / Manual mode

Press         to select between Auto and Manual mode. In manual mode, the thermostat maintains a constant set temperature manually set by the user. In Auto 
mode, the thermostat follows the programmed schedule. 

 

Installation Manual

Sensor Selection

A = Air sensing using built in sensor

F = Floor sensing using remote floor temperature

AF = Air sensing for setpoint, floor sensing for safety cut off

Menu #

Menu 01

 01

Programming Option - 2 options for time/temperature settings  

5_2 = 5 days (Mon - Fri) with same time/temperature settings and 2 days (Sat - Sun) with 

same time/temperature settings              

7_0  = 7 days allow for individual day settings or whole week settings

Floor Temperature Limit - Provides floor temperature protection when using AF function

12/24 Hour clock

Select backlight function

Thermostat Calibration (FLOOR) - By adjusting this figure any discrepancy between

displayed floor temperature and measured floor temperature can be compensated for

Switching differential - The number of degrees difference between switching off at the 

set temperature and on again to reach the set temperature i.e. A 1°C setting will switch 

the thermostat on 0.5 °C below the setpoint and switch it off 0.5 °C above the setpoint 

30 seconds

10,20,30......60 ,ON

12 / 24  

Thermostat Calibration (AIR) - By adjusting this figure any discrepancy between 

displayed air temperature and measured air room temperature can be compensated for

02

03

04

05

06

07

08

09

10

11

Feature Description

Factory Default

Options

0 °C

5_2

5_2  /   7_0

40 °C

20°C ~ 90 °C

  

24  

  

OFF

OFF / ON

A / F /  AF

A / F /  AF

Press         or          to select

Frost protection - Set to ON to maintain a room temperature above 5°C in the event of 

severe low temperatures

1°C

1°C ~ 5°C

-5°C ~ +5°C

0°C

-5°C ~ +5°C

Power

Up/Down

Day of the week

Periods

key lock

AUTO

Anti-frozen

FLOOR

Clock setting

WHT 1000 Thermostat

Explanation of Symbols

Manual Mode

Auto Mode

Heating On

Room Temperature

Floor Temperature

Time

Menu

WiFi symbol

If menu 01 is set to AF. Use menu 05 to choose to show air temperature, floor temperature

This allows users to select between °C or °F.

°C

°C / °F

or to show both floor & air in interval.

option

thermostat is 

turned off

Menu 02

option

Reviews: