2. During hot gas defrost, the fan stops and
the compressor remains running. During
this time, the defrosting icon is displayed.
3. Defrost mode
4. Timer ON/OFF function
Defrost mode
Description
Automatic
defrosting.
sensor in normal
condition.
1. Defrost mode starts when the
compressor runs for 25 minutes and the
temperature of the device drops below-1°C.
In this mode, defrosting starts for 10 minutes after that, the device
returns to normal operation.
If the device is turned on, changing the timer settings results in setting the working time until it
is turned off, while if the device is turned off, changing the timer settings results in setting the
time that must pass until the device is automatically turned on.
32
Automatic
defrosting.
Turn off the machine if it is on, then press the "Timer" button on the control panel. The start of
programming is signaled by flashing "00". Use the "
▲
" or "
▼
" buttons to set the time for
which you want the device to turn on. Constantly holding the button for 2 seconds allows you
to change the parameters faster. During programming, no action is taken on the panel for 10
seconds, the device will remember the last value entered, which will be signaled by flashing
(range from 00 to 24h, default 00).
A. Time programming of device activation: